High frequency resonance characteristics analysis of voltage-source virtual synchronous generator and suppression strategy

被引:1
作者
Li, Zhi [1 ,5 ]
Liu, Mingbo [1 ]
Gong, Yu [2 ,3 ]
Li, Xudong [4 ]
机构
[1] South China Univ Technol, Guangzhou, Peoples R China
[2] North China Elect Power Res Inst Co Ltd, State Grid Jibei Elect Power Co Ltd, Res Inst, Beijing, Peoples R China
[3] State Grid Wind PV Energy Storage Hybrid Power Gen, Beijing, Peoples R China
[4] CGN New Energy Holdings Co Ltd, Beijing, Peoples R China
[5] South China Univ Technol, Sch Elect Power, Guangzhou, Peoples R China
关键词
harmonic distortion; mathematical analysis; optimal control; power convertors; power system simulation; POWER-SYSTEM; SYNCHRONVERTERS INVERTERS; STABILITY;
D O I
10.1049/elp2.12413
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The voltage-source virtual synchronous generator is a grid-forming type power electronic control technology and is able to support converters that have the ability of inertial, primary frequency and voltage regulation. Firstly, the authors build the small-signal model of the voltage-source virtual synchronous generator and conventional converters, compare and analyse the characteristics of the high-frequency resonance modes, the results show that the voltage-source virtual synchronous generator has almost the same high-frequency resonance characteristics as the conventional converter. Secondly, the different control parameters and power grid strength that affect the high-frequency resonance characteristic are analysed with eigenvalue, and the mechanism of voltage-source VSG that caused high-frequency resonance is derived. The leading factor that causes high-frequency resonance is power grid strengths, and the authors proposed introducing virtual impedance into the front-end channel of the current inner loop control strategy to suppress resonance for the voltage-source virtual synchronous generator based on the theoretical analysis with the small-signal model and eigenvalue analysis. In addition, the electromagnetic transient simulation model and RT-LAB controller-in-loop platform are built, and the simulation and experiment results indicate the effectiveness of the virtual impedance control strategy. Similarly with conventional converters, the resonance mode of high-frequency resonance of voltage-source VSG exists, and the damping ratio is small. The dominant factors of HFR of voltage-source VSG is grid-side parameters. Based on the generated mechanism of HFR and the dominant factors, the novelty control strategy of voltage-source VSG is proposed by introducing virtual impedance into the front-end channel of the current inner loop of voltage-source VSG, as reshaping the control configuration. In addition, root locus analysis based on the small-signal model of voltage-source VSG, electromagnetic transient simulation and RT-LAB controller-in-loop experimental verified that this proposed method is effective on suppression HFR of voltage-source VSG.image
引用
收藏
页码:582 / 593
页数:12
相关论文
共 31 条
[1]   Virtual synchronous generators: A survey and new perspectives [J].
Bevrani, Hassan ;
Ise, Toshifumi ;
Miura, Yushi .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 54 :244-254
[2]  
[柴建云 Chai Jianyun], 2018, [电力系统自动化, Automation of Electric Power Systems], V42, P17
[3]   Parameter Constraints for Virtual Synchronous Generator Considering Stability [J].
Chen, Junru ;
O'Donnell, Terence .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (03) :2479-2481
[4]   Small-Disturbance Stability of a Wind Farm With Virtual Synchronous Generators Under the Condition of Weak Grid Connection [J].
Du, Wenjuan ;
Dong, Wenkai ;
Wang, Yang ;
Wang, Haifeng .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (06) :5500-5511
[5]   Reduced-Order Method for Detecting the Risk and Tracing the Sources of Small-Signal Oscillatory Instability in a Power System With a Large Number of Wind Farms [J].
Du, Wenjuan ;
Wang, Yijun ;
Wang, H. F. ;
Xiao, Xianyong .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (02) :1563-1582
[6]   Dynamic Aggregation of Same Wind Turbine Generators in Parallel Connection for Studying Oscillation Stability of a Wind Farm [J].
Du, Wenjuan ;
Dong, Wenkai ;
Wang, Haifeng ;
Cao, Jun .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (06) :4694-4705
[7]   Power System Small-Signal Angular Stability Affected by Virtual Synchronous Generators [J].
Du, Wenjuan ;
Fu, Qiang ;
Wang, H. F. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (04) :3209-3219
[8]   Damping Low-Frequency Oscillations Through VSC-HVdc Stations Operated as Virtual Synchronous Machines [J].
Huang, Linbin ;
Xin, Huanhai ;
Wang, Zhen .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (06) :5803-5818
[9]   Control of Photovoltaic Systems for Enhanced Short-Term Voltage Stability and Recovery [J].
Lammert, Gustav ;
Premm, Daniel ;
Ospina, Luis David Pabon ;
Boemer, Jens C. ;
Braun, Martin ;
Van Cutsem, Thierry .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (01) :243-254
[10]  
[李少林 Li Shaolin], 2019, [电力系统自动化, Automation of Electric Power Systems], V43, P64