Systematic Evaluation of the Impact of Lung Segmentation Methods on 4-Dimensional Computed Tomography Ventilation Imaging Using a Large Patient Database

被引:3
作者
Chen, Yingxuan [1 ]
Pahlavian, Soroush Heidari [2 ]
Jacobs, Paul [2 ]
Neupane, Taindra [1 ]
Forghani-Arani, Farnoush [3 ]
Castillo, Edward [4 ]
Castillo, Richard [5 ]
Vinogradskiy, Yevgeniy [1 ]
机构
[1] Thomas Jefferson Univ, Dept Radiat Oncol, Philadelphia, PA 19144 USA
[2] MIM Software Inc, Beachwood, OH USA
[3] Washington Univ, Dept Radiat Oncol, St Louis, MO USA
[4] Univ Texas Austin, Dept Biomed Engn, Austin, TX USA
[5] Emory Univ, Dept Radiat Oncol, Atlanta, GA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2024年 / 118卷 / 01期
基金
美国国家卫生研究院;
关键词
INTENSITY-MODULATED RADIOTHERAPY; PULMONARY VENTILATION; FUNCTIONAL AVOIDANCE; REGISTRATION ALGORITHMS; REGIONAL VENTILATION; GUIDED RADIOTHERAPY; CLINICAL VALIDATION; CT VENTILATION; TISSUE; REDUCTION;
D O I
10.1016/j.ijrobp.2023.08.017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A novel form of lung functional imaging applied for functional avoidance radiation therapy has been developed that uses 4-dimensional computed tomography (4DCT) data and image processing techniques to calculate lung ventilation (4DCT-ventilation). Lung segmentation is a common step to define a region of interest for 4DCT-ventilation generation. The purpose of this study was to quantitatively evaluate the sensitivity of 4DCT-ventilation imaging using different lung segmentation methods. Methods and Materials: The 4DCT data of 350 patients from 2 institutions were used. Lung contours were generated using 3 methods: (1) reference segmentations that removed airways and pulmonary vasculature manually (Lung-Manual), (2) standard lung contours used for planning (Lung-RadOnc), and (3) artificial intelligence (AI)-based contours that removed the airways and pulmonary vasculature (Lung-AI). The AI model was based on a residual 3-dimensional U-Net and was trained using the Lung-Manual contours of 279 patients. We compared the Lung-RadOnc or Lung-AI with Lung-Manual contours for the entire 4DCT-ventilation functional avoidance process including lung segmentation (surface Dice similarity coefficient [Surface DSC]), 4DCT-ventilation generation (correlation), and subanalysis of 10 patients on a dosimetric endpoint (percentage of high functional volume of lung receiving >= 20 Gy [fV20{%}]).Results: Surface DSC comparing Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI contours was 0.40 +/- 0.06 and 0.86 +/- 0.04, respectively. The correlation between 4DCT-ventilation images generated with Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI were 0.48 +/- 0.14 and 0.85 +/- 0.14, respectively. The difference in fV20[%] between 4DCT-ventilation generated with Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI was 2.5% +/- 4.1% and 0.3% +/- 0.5%, respectively.Conclusions: Our work showed that using standard planning lung contours can result in significantly variable 4DCT-ventila-tion images. The study demonstrated that AI-based segmentations generate lung contours and 4DCT-ventilation images that are similar to those generated using manual methods. The significance of the study is that it characterizes the lung segmentation sensitivity of the 4DCT-ventilation process and develops methods that can facilitate the integration of this novel imaging in busy clinics.(c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:242 / 252
页数:11
相关论文
共 49 条
[1]   Establishing a Relationship Between Radiosensitivity of Lung Tissue and Ventilation [J].
Bayouth, J. ;
Du, K. ;
Christensen, G. ;
Smith, B. ;
Buatti, J. ;
Reinhardt, J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03) :S31-S32
[2]   Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data [J].
Brennan, Douglas ;
Schubert, Leah ;
Diot, Quentin ;
Castillo, Richard ;
Castillo, Edward ;
Guerrero, Thomas ;
Martel, Mary K. ;
Linderman, Derek ;
Gaspar, Laurie E. ;
Miften, Moyed ;
Kavanagh, Brian D. ;
Vinogradskiy, Yevgeniy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (02) :423-429
[3]   Robust HU-based CT ventilation from an integrated mass conservation formulation [J].
Castillo, Edward ;
Vinogradskiy, Yevgeniy ;
Castillo, Richard .
MEDICAL PHYSICS, 2019, 46 (11) :5036-5046
[4]   Robust CT ventilation from the integral formulation of the Jacobian [J].
Castillo, Edward ;
Castillo, Richard ;
Vinogradskiy, Yevgeniy ;
Dougherty, Michele ;
Solis, David ;
Myziuk, Nicholas ;
Thompson, Andrew ;
Guerra, Rudy ;
Nair, Girish ;
Guerrero, Thomas .
MEDICAL PHYSICS, 2019, 46 (05) :2115-2125
[5]   The numerical stability of transformation-based CT ventilation [J].
Castillo, Edward ;
Castillo, Richard ;
Vinogradskiy, Yevgeniy ;
Guerrero, Thomas .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (04) :569-580
[6]   Least median of squares filtering of locally optimal point matches for compressible flow image registration [J].
Castillo, Edward ;
Castillo, Richard ;
White, Benjamin ;
Rojo, Javier ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15) :4827-4843
[7]   Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis [J].
Castillo, Richard ;
Castillo, Edward ;
McCurdy, Matthew ;
Gomez, Daniel R. ;
Block, Alec M. ;
Bergsma, Derek ;
Joy, Sarah ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07) :1855-1871
[8]   Ventilation from four-dimensional computed tomography: density versus Jacobian methods [J].
Castillo, Richard ;
Castillo, Edward ;
Martinez, Josue ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) :4661-4685
[9]   The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer [J].
Christian, JA ;
Partridge, M ;
Nioutsikou, E ;
Cook, G ;
McNair, HA ;
Cronin, B ;
Courbon, F ;
Bedford, JL ;
Brada, M .
RADIOTHERAPY AND ONCOLOGY, 2005, 77 (03) :271-277
[10]   Reproducibility of registration-based measures of lung tissue expansion [J].
Du, Kaifang ;
Bayouth, John E. ;
Cao, Kunlin ;
Christensen, Gary E. ;
Ding, Kai ;
Reinhardt, Joseph M. .
MEDICAL PHYSICS, 2012, 39 (03) :1595-1608