Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed prostheses: A prospective study

被引:20
作者
Yan, Yuwei [1 ]
Lin, Xiao [1 ]
Yue, Xinxin [1 ]
Geng, Wei [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Stomatol Hosp, Dept Dent Implant Ctr, Sch Stomatol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Stomatol Hosp, Dept Dent Implant Ctr, Sch Stomatol, 4 Tian Tan Xi Li, Beijing 100050, Peoples R China
基金
中国国家自然科学基金;
关键词
CONVENTIONAL IMPRESSIONS; MULTIPLE IMPLANTS; PHOTOGRAMMETRY; PRECISION; REHABILITATION; FIT; POSITIONS; MISFIT;
D O I
10.1016/j.prosdent.2022.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Conventional impression techniques for complete arch implant-supported prostheses are technique-sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer an alternative to conventional impression making. Purpose. The purpose of this prospective study was to compare the accuracy of IOS and SPG for complete arch implant scans and to evaluate the passive fit of frameworks fabricated with SPG.Material and methods. Laboratory scanning of gypsum casts, SPG, and IOS were performed for all participants. The data regarding the abutment platform were superimposed to calculate the 3D deviation of SPG and IOS compared with that of laboratory scanning as an evaluation of accuracy. The effect of implant position and number on accuracy was analyzed. The more accurate technique between SPG and IOS was used to fabricate the titanium frameworks, as was laboratory scanning. The passive fit of the frameworks was assessed by clinical examination, the Sheffield test, and panoramic radiography.Results. Seventeen participants (21 arches, 120 implants) were included. The accuracy of SPG ranged from 2.70 mu m to 92.80 mu m, with a median (Q1, Q3) of 17.00 (11.68, 22.50) mu m, which was significantly more accurate than that of IOS, ranging from 21.30 mu m to 815.60 mu m, with a median (Q1, Q3) of 48.95 (34.78, 75.88) mu m. No significant correlation was found between position or number of implants and 3D deviation in the SPG group. A weak positive correlation was found between implant number and 3D deviation in the IOS group. SPG and laboratory scanning were used to fabricate titanium frameworks. The passive fit between the frameworks and abutment platforms was confirmed.Conclusions. SPG, which was not affected by position or number of implants, was more accurate than IOS and comparable with laboratory scanning. The frameworks fabricated based on SPG and laboratory scanning were comparable in their passive fit. The SPG technique may be an alternative to laboratory scanning for complete arch implant scans. (J Prosthet Dent 2023;130:564-72)
引用
收藏
页码:564 / 572
页数:9
相关论文
共 43 条
[41]   The accuracy of computer-guided implant surgery with tooth-supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study [J].
Derksen, Wiebe ;
Wismeijer, Daniel ;
Fluegge, Tabea ;
Hassan, Bassam ;
Tahmaseb, Ali .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (10) :1005-1015
[42]   Short-term report of an ongoing prospective cohort study evaluating the outcome of full-arch implant-supported fixed hybrid polyetheretherketone-acrylic resin prostheses and the All-on-Four concept [J].
Malo, Paulo ;
Nobre, Miguel de Araujo ;
Guedes, Carlos Moura ;
Almeida, Ricardo ;
Silva, Antonio ;
Sereno, Nuno ;
Legatheaux, Joao .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) :692-702
[43]   Retrospective 2-to 7-Year Follow-Up Study of 20 Double Full-Arch Implant-Supported Monolithic Zirconia Fixed Prostheses: Measurements and Recommendations for Optimal Design [J].
Rojas Vizcaya, Fernando .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (06) :501-508