Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed prostheses: A prospective study

被引:20
作者
Yan, Yuwei [1 ]
Lin, Xiao [1 ]
Yue, Xinxin [1 ]
Geng, Wei [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Stomatol Hosp, Dept Dent Implant Ctr, Sch Stomatol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Stomatol Hosp, Dept Dent Implant Ctr, Sch Stomatol, 4 Tian Tan Xi Li, Beijing 100050, Peoples R China
基金
中国国家自然科学基金;
关键词
CONVENTIONAL IMPRESSIONS; MULTIPLE IMPLANTS; PHOTOGRAMMETRY; PRECISION; REHABILITATION; FIT; POSITIONS; MISFIT;
D O I
10.1016/j.prosdent.2022.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Conventional impression techniques for complete arch implant-supported prostheses are technique-sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer an alternative to conventional impression making. Purpose. The purpose of this prospective study was to compare the accuracy of IOS and SPG for complete arch implant scans and to evaluate the passive fit of frameworks fabricated with SPG.Material and methods. Laboratory scanning of gypsum casts, SPG, and IOS were performed for all participants. The data regarding the abutment platform were superimposed to calculate the 3D deviation of SPG and IOS compared with that of laboratory scanning as an evaluation of accuracy. The effect of implant position and number on accuracy was analyzed. The more accurate technique between SPG and IOS was used to fabricate the titanium frameworks, as was laboratory scanning. The passive fit of the frameworks was assessed by clinical examination, the Sheffield test, and panoramic radiography.Results. Seventeen participants (21 arches, 120 implants) were included. The accuracy of SPG ranged from 2.70 mu m to 92.80 mu m, with a median (Q1, Q3) of 17.00 (11.68, 22.50) mu m, which was significantly more accurate than that of IOS, ranging from 21.30 mu m to 815.60 mu m, with a median (Q1, Q3) of 48.95 (34.78, 75.88) mu m. No significant correlation was found between position or number of implants and 3D deviation in the SPG group. A weak positive correlation was found between implant number and 3D deviation in the IOS group. SPG and laboratory scanning were used to fabricate titanium frameworks. The passive fit between the frameworks and abutment platforms was confirmed.Conclusions. SPG, which was not affected by position or number of implants, was more accurate than IOS and comparable with laboratory scanning. The frameworks fabricated based on SPG and laboratory scanning were comparable in their passive fit. The SPG technique may be an alternative to laboratory scanning for complete arch implant scans. (J Prosthet Dent 2023;130:564-72)
引用
收藏
页码:564 / 572
页数:9
相关论文
共 43 条
[21]   Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: A comparative clinical study [J].
Zhang, Yi-Jie ;
Qian, Shu-Jiao ;
Lai, Hong-Chang ;
Shi, Jun-Yu .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02) :212-218
[22]   Accuracy of complete arch nonsplinting and noncalibrated splinting implant scanning techniques recorded by using five intraoral scanners [J].
Revilla-Leon, Marta ;
Cascos, Rocio ;
Lawand, Ghida ;
Barmak, Abdul B. ;
Kois, John C. ;
Gomez-Polo, Miguel .
JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (06) :1581e1-1581e10
[23]   Evaluation of the accuracy of digital workflow for implant-supported full-arch fixed dental prostheses using a novel micro-CT measurement technique [J].
Fouda, Amira ;
Wyatt, Chris ;
McCullagh, Anthony ;
Vora, Siddharth R. ;
Ford, Nancy L. ;
Gebril, Mohamed .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
[24]   A completely digital workflow aided by cone beam computed tomography scanning to maintain jaw relationships for implant-supported fixed complete dentures: A clinical study [J].
Yan, Yuwei ;
Yue, Xinxin ;
Lin, Xiao ;
Geng, Wei .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (01) :116-124
[25]   Comparative analyses of accuracy between digital and conventional impressions for complete-arch implant-supported fixed dental prostheses-A systematic review and meta-analysis [J].
Alfaraj, Amal ;
Alqudaihi, Fatema ;
Khurshid, Zohaib ;
Qadiri, Osama ;
Lin, Wei-Shao .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
[26]   Comparison of the accuracy between conventional and various digital implant impressions for an implant-supported mandibular complete arch-fixed prosthesis: An in vitro study [J].
Kosago, Pitchaporn ;
Ungurawasaporn, Chatcharwin ;
Kukiattrakoon, Boonlert .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07) :616-624
[27]   Influence of scanning protocol on the accuracy of complete-arch digital implant scans: An in vitro study [J].
Hamilton, Adam ;
Negreiros, William Matthew ;
Jain, Shruti ;
Finkelman, Matthew ;
Gallucci, German O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) :641-651
[28]   Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: An in vitro study [J].
Diker, Burcu ;
Tak, Onjen .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02) :187-194
[29]   Impact of scanning interruptions on accuracy of implant-supported full-arch scans: An in-vitro pilot study [J].
Limones, Alvaro ;
Cakmak, Gulce ;
Fonseca, Manrique ;
Roccuzzo, Andrea ;
Cobo-Vazquez, Carlos ;
Gomez-Polo, Miguel ;
Molinero-Mourelle, Pedro .
JOURNAL OF DENTISTRY, 2025, 153
[30]   Accuracy of the Different Materials Used to Fabricate a Verification Jig of Implant-Supported Fixed Complete Dental Prostheses: An In Vitro Study [J].
Aljohani, Mawaddah S. ;
Bukhari, Heba A. ;
Alshehri, Mayar ;
Alamoudi, Ahmed .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)