摘要
Peripheral nerve stimulation is being investigated as a therapeutic tool in several clinical scenarios. However, the adopted devices have restricted ability to obtain desired outcomes with tolerable off-target effects. Recent promising solutions are not yet employed in clinical practice due to complex required surgeries, lack of long-term stability, and implant invasiveness. Here, we aimed to design a neural interface to address these issues, specifically dimensioned for pudendal and sacral nerves to potentially target sexual, bladder, or bowel dysfunctions. We designed the adaptable intrafascicular radial electrode (AIR) through realistic computational models. They account for detailed human anatomy, inhomogeneous anisotropic conductance, following the trajectories of axons along curving and branching fascicles, and detailed biophysics of axons. The model was validated against available experimental data. Thanks to computationally efficient geometry-based selectivity estimations we informed the electrode design, optimizing its dimensions to obtain the highest selectivity while maintaining low invasiveness. We then compared the AIR with state-of-the-art electrodes, namely InterStim leads, multipolar cuffs and transversal intrafascicular multichannel electrodes (TIME). AIR, comprising a flexible substrate, surface active sites, and radially inserted intrafascicular needles, is designed to be implanted in a few standard steps, potentially enabling fast implants. It holds potential for repeatable stimulation outcomes thanks to its radial structural symmetry. When compared in-silico, AIR consistently outperformed cuff electrodes and InterStim leads in terms of recruitment threshold and stimulation selectivity. AIR performed similarly or better than a TIME, with quantified less invasiveness. Finally, we showed how AIR can adapt to different nerve sizes and varying shapes while maintaining high selectivity. The AIR electrode shows the potential to fill a clinical need for an effective peripheral nerve interface. Its high predicted performance in all the identified requirements was enabled by a model-based approach, readily applicable for the optimization of electrode parameters in any peripheral nerve stimulation scenario. Author summaryThe potential of peripheral nerve stimulation in treating health conditions is limited by current technology, most importantly by the selectivity of the electrodes employed, i.e., their ability to obtain the desired clinical outcomes with limited collateral effects. Using highly realistic tridimensional models of the nerves and of the electrodes there implanted, we are able to estimate the outcome of stimulating with a specified electrode and protocol by simulating the behavior of each axon of the nerve. We used this computational framework to optimize key geometric parameters of a novel electrode design, specifically dimensioned for pudendal and sacral nerve stimulation for the potential treatment of bladder, bowel, and sexual dysfunctions. Within this in-silico framework, our electrode has shown promising results against state-of-the-art electrodes in all identified benchmarks, showing potential to meet the clinical need for a selective, quickly implantable electrode. The electrode optimization method we proposed can be applied in many other peripheral nerve stimulation scenarios for testing and optimizing electrode design parameters, aiding in the development of next-generation devices.
引用
收藏
页数:21
相关论文
共 70 条
[1]   Model-based geometrical optimisation and in vivo validation of a spatially selective multielectrode cuff array for vagus nerve neuromodulation [J].
Aristovich, Kirill ;
Donega, Matteo ;
Fjordbakk, Cathrine ;
Tarotin, Ilya ;
Chapman, Christopher A. R. ;
Viscasillas, Jaime ;
Stathopoulou, Thaleia-Rengina ;
Crawford, Abbe ;
Chew, Daniel ;
Perkins, Justin ;
Holder, David .
JOURNAL OF NEUROSCIENCE METHODS, 2021, 352
[2]   Intrafascicular peripheral nerve stimulation produces fine functional hand movements in primates [J].
Badi, Marion ;
Wurth, Sophie ;
Scarpato, Ilaria ;
Roussinova, Evgenia ;
Losanno, Elena ;
Bogaard, Andrew ;
Delacombaz, Maude ;
Borgognon, Simon ;
Cvancara, Paul ;
Fallegger, Florian ;
Su, David K. ;
Schmidlin, Eric ;
Courtine, Gregoire ;
Bloch, Jocelyne ;
Lacour, Stephanie P. ;
Stieglitz, Thomas ;
Rouiller, Eric M. ;
Capogrosso, Marco ;
Micera, Silvestro .
SCIENCE TRANSLATIONAL MEDICINE, 2021, 13 (617)
[3]   Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles [J].
Badia, Jordi ;
Boretius, Tim ;
Andreu, David ;
Azevedo-Coste, Christine ;
Stieglitz, Thomas ;
Navarro, Xavier .
JOURNAL OF NEURAL ENGINEERING, 2011, 8 (03)
[4]   Summary of the Recommendations on Sexual Dysfunctions in Women [J].
Basson, Rosemary ;
Wierman, Margaret E. ;
van Lankveld, Jacques ;
Brotto, Lori .
JOURNAL OF SEXUAL MEDICINE, 2010, 7 (01) :314-326
[5]   Overview of the Clinical Applications of Vagus Nerve Stimulation [J].
Beekwilder, J. P. ;
Beems, T. .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2010, 27 (02) :130-138
[6]   Programming settings and recharge interval in a prospective study of a rechargeable sacral neuromodulation system for the treatment of overactive bladder [J].
Blok, Bertil ;
Van Kerrebroeck, Philip ;
de Wachter, Stefan ;
Ruffion, Alain ;
Van der Aa, Frank ;
Jairam, Ranjana ;
Perrouin-Verbe, Marie ;
Elneil, Sohier .
NEUROUROLOGY AND URODYNAMICS, 2018, 37 :S17-S22
[7]   A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve [J].
Boretius, Tim ;
Badia, Jordi ;
Pascual-Font, Aran ;
Schuettler, Martin ;
Navarro, Xavier ;
Yoshida, Ken ;
Stieglitz, Thomas .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :62-69
[8]  
Capogrosso Marco, 2020, Bioelectron Med, V6, P10, DOI [10.1186/s42234-020-00047-3, 10.1186/s42234-020-00047-3]
[9]  
Carnevale N.T. Hines., 2006, NEURON BOOK, DOI DOI 10.1017/CBO9780511541612
[10]   Quantitative estimation of nerve fiber engagement by vagus nerve stimulation using physiological markers [J].
Chang, Yao-Chuan ;
Cracchiolo, Marina ;
Ahmed, Umair ;
Mughrabi, Ibrahim ;
Gabalski, Arielle ;
Daytz, Anna ;
Rieth, Loren ;
Becker, Lance ;
Datta-Chaudhuri, Timir ;
Al-Abed, Yousef ;
Zanos, Theodoros P. ;
Zanos, Stavros .
BRAIN STIMULATION, 2020, 13 (06) :1617-1630