MCNPX Estimation of Photoneutron Dose to Eye Voxel Anthropomorphic Phantom From 18 MV Linear Accelerator

被引:0
作者
Alghamdi, Ali A. A. [1 ,2 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Appl Med Sci, Dept Radiol Sci, Dammam, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 2435, Dammam 31441, Saudi Arabia
来源
DOSE-RESPONSE | 2023年 / 21卷 / 02期
关键词
photoneutron dose; eye model; voxel anthropomorphic phantom; weight window; MONTE-CARLO; NEUTRON; RADIOTHERAPY; COMPOSITES; THERAPY; FIELD;
D O I
10.1177/15593258231169807
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The dose due to photoneutron contamination outside the field of irradiation can be significant when using high-energy linear accelerators. The eye is a radiation-sensitive organ, and this risk increases when high linear energy transfer neutron radiation is involved. This study aimed to provide a fast method to estimate photoneutron dose to the eye during radiotherapy. A typical high-energy linear accelerator operating at 18 MV was simulated using the Monte Carlo N-Particle Transport Code System extended version (MCNPX 2.5.0). The latest International Atomic Energy Agency photonuclear data library release was integrated into the code, accounting for the most known elements and isotopes used in typical linear accelerator construction. The photoneutron flux from a 5 x 5 cm(2) field size was scored at the treatment table plane and used as a new source for estimating the absorbed dose in a high-resolution eye voxel anthropomorphic phantom. In addition, common shielding media were tested to reduce the photoneutron dose to the eye using common shielding materials. Introducing a 2 cm thickness of common neutron shielding medium reduced the total dose received in the eye voxel anthropomorphic phantom by 54%. In conclusion, individualized treatment based on photoneutron dose assessment is essential to better estimate the secondary dose inside or outside the field of irradiation.
引用
收藏
页数:7
相关论文
共 30 条
  • [11] H Dowlatabadi, 2020, J Biomed Phys Eng, V10, P679, DOI 10.31661/JBPE.V0I0.939
  • [12] Hendricks J S., 2000, An assessment of MCNP weight windows
  • [13] Hoogenboom JE, 2005, PROC MONTE CARLO 200
  • [14] International Atomic Energy Agency (IAEA), 2022, IAEA EV PHOT DAT LIB
  • [15] Photoneutron-induced damage reduction for cardiac implantable electronic devices using neutron-shielding sheets in high-energy X-ray radiotherapy: A phantom study
    Kakino, Ryo
    Nakamura, Mitsuhiro
    Hu, Naonori
    Iramina, Hiraku
    Tanaka, Hiroki
    Sakurai, Yoshinori
    Mizowaki, Takashi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 151 - 159
  • [16] Essential considerations for accurate evaluation of photoneutron contamination in Radiotherapy
    Karimi, Amir Hossein
    Brkic, Hrvoje
    Shahbazi-Gahrouei, Daryoush
    Haghighi, Somayeh Biparva
    Jabbari, Iraj
    [J]. APPLIED RADIATION AND ISOTOPES, 2019, 145 : 24 - 31
  • [17] Khabaz R., 2020, Iranian Journal of Medical Physics, V17, P366
  • [18] Assessment and measurement of the photoneutron field produced in the varian medical linear accelerator
    Kim, Hong Suk
    Lee, Jai Ki
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2007, 44 (01) : 95 - 101
  • [19] Current status of disposal and measurement analysis of radioactive components in linear accelerators in Korea
    Kwon, Na Hye
    Shin, Dong Oh
    Kim, Jinsung
    Yoo, Jaeryong
    Park, Min Seok
    Kim, Kum Bae
    Kim, Dong Wook
    Choi, Sang Hyoun
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (02) : 507 - 513
  • [20] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    Ma, A.
    Awotwi-Pratt, J.
    Alghamdi, A.
    Alfuraih, A.
    Spyrou, N. M.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 119 - 123