Waste heat recovery solution based on a heat pipe heat exchanger for the aluminium die casting industry

被引:38
作者
Jouhara, Hussam [1 ,5 ]
Nieto, Nerea [2 ]
Egilegor, Bakartxo [2 ]
Zuazua, Josu [3 ]
Gonz, Eva
Yebra, Ignacio [4 ]
Igesias, Alfredo [4 ]
Delpech, Bertrand [1 ]
Almahmoud, Sulaiman [1 ]
Brough, Daniel [1 ]
Malinauskaite, Jurgita [1 ]
Vlasopoulos, Antonis [1 ]
Hill, Mark [1 ]
Axcell, Brian [1 ]
机构
[1] Brunel Univ London, Heat Pipe & Thermal Management Res Grp, Uxbridge UB83PH, England
[2] Technol Res Ctr, Ikerlan, Arrasate Mondragon 20500, Spain
[3] Fagor Ederlan SCoop, Arrasate Mondragon 20500, Spain
[4] Insertec, Basauri 48970, Spain
[5] Vytautas Magnus Univ, Akad, Studentu Str 11, LT-53362 Kaunas, Lithuania
基金
欧盟地平线“2020”;
关键词
Heat Pipes; Waste heat recovery; Energy efficiency; Aluminium die casting industry; WATER;
D O I
10.1016/j.energy.2022.126459
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analysis of the end use of energy in the EU reveals that industry is one of the three dominant categories, which accounts for 26.1% of the final end use of energy. In the case of the aluminium industry, approximately 70% of energy consumption is due to heat and thermal processes, highlighting a vast potential for waste heat recovery technologies. Within the aluminium die casting industry, liquid aluminium is cast, formed, cooled, and further processed within a thermal heat process, which includes three sub-processes: solubilising, quenching, and ageing. In the case presented, a thermal heat process is the second most energy intensive process within the factory, and the ageing heat treatment furnace accounts for 15% of the thermal heat process. The thermal heat treatment generates a significant amount of waste heat. The recovery of that waste heat, with minimal risk of cross contamination between streams and reduced chance of equipment failure, has been achieved via the use of a heat pipe heat exchanger (HPHE). The HPHE has been designed, manufactured, and installed in the solution furnace exhaust stack. The HPHE was designed to recover up to 88.6 kW in steady state operating conditions at 400 degrees C. The return on investment has been evaluated at 35 months with an expected CO2 emissions reduction of 86 tCO2/year when best engineering practices are applied. Furthermore, a theoretical modelling tool to predict the thermal performance of the HPHE was developed and validated within a +/- 20% deviation from the experimental results. This paper further presents the development of the theoretical model to allow a characterisation of HPHE technology and will act as a guideline for the design of HPHEs within the aluminium industry.
引用
收藏
页数:17
相关论文
共 57 条
[1]   Numerical investigation of effect of fill ratio and inclination angle on a thermosiphon heat pipe thermal performance [J].
Alammar, Ahmed A. ;
Al-Dadah, Raya K. ;
Mahmoud, Saad M. .
APPLIED THERMAL ENGINEERING, 2016, 108 :1055-1065
[2]   CFD modeling of flow and heat transfer in a thermosyphon [J].
Alizadehdakhel, Asghar ;
Rahimi, Masoud ;
Alsairafi, Ammar Abdulaziz .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (03) :312-318
[3]  
[Anonymous], EUR LEX 52011DC0112
[4]  
[Anonymous], CO2 EM GLOB EN REV A
[5]  
[Anonymous], AL AN
[6]  
[Anonymous], EL PRIC WORLD
[7]  
[Anonymous], ETEKINA
[8]  
[Anonymous], WAST HEAT REC METH T, P2
[9]  
[Anonymous], 2010, Study of Energy efficiency -Technical Chamber of Greece
[10]  
Bergman TL., 2011, FUNDAMENTALS HEAT MA