Hybrid time-frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

被引:4
|
作者
Retter, Jonathan E. [1 ,2 ]
Koll, Matthew [1 ,3 ]
Dedic, Chloe E. [4 ]
Danehy, Paul M. [5 ]
Richardson, Daniel R. [1 ]
Kearney, Sean P. [1 ]
机构
[1] Engn Sci Ctr, Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Natl Inst Aerospace, Hampton, VA 23666 USA
[3] Univ Illinois, Dept Aerosp Engn, Urbana, IL 61801 USA
[4] Univ Virginia, Dept Mech & Aerosp Engn, Charlottesville, VA 22911 USA
[5] NASA Langley Res Ctr, Hampton, VA 22681 USA
关键词
FILTERED RAYLEIGH-SCATTERING; LASER-INDUCED FLUORESCENCE; FS/PS ROTATIONAL CARS; UNDEREXPANDED JETS; SPECTROSCOPY; LINEWIDTHS; VELOCITY; N-2; NITROGEN; DENSITY;
D O I
10.1364/AO.472831
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a hybrid time-frequency spectroscopic method for simultaneous temperature/pressure mea-surements in nonreacting compressible flows with known gas composition. Hybrid femtosecond-picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an similar to 5-mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay (t1 = 0 ps) and pressure from spectra obtained at probe delays of t2 = 150-1000 ps, where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded airjet permits evaluation of this hybrid time-frequency domain approach for temperature and pressure measurements across a wide range of low-temperature-low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approach-ing 1%-2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four (t2/tR > 4). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapo-lated high-temperature Q-branch linewidths are presented. Considering all measurements with t2/tR >= 4.0, measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representingacombination of instrument noise and fluid fluctuations of 5.0%.(c) 2022 Optica Publishing Group
引用
收藏
页码:50 / 62
页数:13
相关论文
共 14 条
  • [1] Pressure measurements using hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering
    Kearney, Sean P.
    Danehy, Paul M.
    OPTICS LETTERS, 2015, 40 (17) : 4082 - 4085
  • [2] H 2 chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering thermometry at high temperature and pressure
    Chang, Ziqiao
    Gejji, Rohan m.
    Gu, Mingming
    Lucht, Robert p.
    OPTICS EXPRESS, 2024, 32 (08) : 13701 - 13719
  • [3] Temperature measurements in metalized propellant combustion using hybrid fs/ps coherent anti-Stokes Raman scattering
    Kearney, Sean P.
    Guildenbecher, Daniel R.
    APPLIED OPTICS, 2016, 55 (18) : 4958 - 4966
  • [4] Rotational coherence imaging and control for CN molecules through time-frequency resolved coherent anti-Stokes Raman scattering
    Lindgren, Johan
    Hulkko, Eero
    Pettersson, Mika
    Kiljunen, Toni
    JOURNAL OF CHEMICAL PHYSICS, 2011, 135 (22):
  • [5] Dual-pump vibrational/rotational femtosecond/picosecond coherent anti-Stokes Raman scattering temperature and species measurements
    Dedic, Chloe E.
    Miller, Joseph D.
    Meyer, Terrence R.
    OPTICS LETTERS, 2014, 39 (23) : 6608 - 6611
  • [6] Probe-pulse optimization for nonresonant suppression in hybrid fs/ps coherent anti-Stokes Raman scattering at high temperature
    Miller, Joseph D.
    Slipchenko, Mikhail N.
    Meyer, Terrence R.
    OPTICS EXPRESS, 2011, 19 (14): : 13326 - 13333
  • [7] Sensitive hybrid femtosecond/picosecond vibrational coherent anti-Stokes Raman scattering thermometry using optimized probe time delays
    Zhao, Huijie
    Tian, Ziyang
    Wu, Tao
    Li, Yan
    Wei, Haoyun
    APPLIED PHYSICS LETTERS, 2020, 116 (11)
  • [8] Dual-pump coherent anti-Stokes Raman scattering system for temperature and species measurements in an optically accessible high-pressure gas turbine combustor facility
    Thariyan, Mathew P.
    Bhuiyan, Aizaz H.
    Meyer, Scott E.
    Naik, Sameer V.
    Gore, Jay P.
    Lucht, Robert P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (01)
  • [9] Dual-Pump Vibrational Coherent Anti-Stokes Raman Scattering System Developed for Simultaneous Temperature and Relative Nitrogen-Water Vapor Concentration Measurements
    Too, Amon
    Sidiropoulos, Evaggelos
    Holz, Yannik
    Karuri, Nancy Wangechi
    Seeger, Thomas
    OPTICS, 2023, 4 (04): : 613 - 624
  • [10] Communication: Hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering thermometry using a narrowband time-asymmetric probe pulse
    Stauffer, Hans U.
    Miller, Joseph D.
    Roy, Sukesh
    Gord, James R.
    Meyer, Terrence R.
    JOURNAL OF CHEMICAL PHYSICS, 2012, 136 (11):