In Vivo Corneal Stiffness Mapping by the Stress-Strain Index Maps and Brillouin Microscopy

被引:11
作者
Lopes, Bernardo T. [1 ,2 ]
Elsheikh, Ahmed [1 ,3 ,4 ,5 ]
机构
[1] Univ Liverpool, Sch Engn, Brownlow Hill, Liverpool L69 3GH, Merseyside, England
[2] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[3] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing, Peoples R China
[4] Moorfields Eye Hosp NHS Fdn Trust, Natl Inst Hlth Res NIHR Biomed Res Ctr Ophthalmol, London, England
[5] UCL Inst Ophthalmol, London, England
关键词
Cornea; biomechanics; mapping; ectasia; keratoconus; CROSS-LINKING; COLLAGEN ORGANIZATION; SCATTERING; KERATOCONUS; LENS;
D O I
10.1080/02713683.2022.2081979
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The study of corneal stiffness in vivo has numerous clinical applications such as the measurement of intraocular pressure, the preoperative screening for iatrogenic ectasia after laser vision correction surgery and the diagnosis and treatment of corneal ectatic diseases such as keratoconus. The localised aspect of the microstructure deterioration in keratoconus leading to local biomechanical softening, corneal bulging, irregular astigmatism and ultimately loss of vision boosted the need to map the corneal stiffness to identify the regional biomechanical failure. Currently, two methods to map the corneal stiffness in vivo are integrated into devices that are either already commercially available or about to be commercialised: the stress-strain index (SSI) maps and the Brillouin Microscopy (BM). The former method produces 2D map of stiffness across the corneal surface, developed through numerical simulations using the corneal shape, its microstructure content, and the deformation behaviour under air-puff excitation. It estimates the whole stress-strain behaviour, making it possible to obtain the material tangent modulus under different intraocular pressure levels. On the other hand, BM produces a 3D map of the corneal longitudinal modulus across the corneal surface and thickness. It uses a low-power near-infrared laser beam and through a spectral analysis of the returned signal, it assesses the mechanical compressibility of the tissue as measured by the longitudinal modulus. In this paper, these two techniques are reviewed, and their advantages and limitations discussed.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 52 条
  • [1] Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
    Ambrosio, Renato, Jr.
    Ramos, Isaac
    Luz, Allan
    Faria, Fernando Correa
    Steinmueller, Andreas
    Krug, Matthias
    Belin, Michael W.
    Roberts, Cynthia Jane
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2013, 72 (02) : 99 - 102
  • [2] Bergmanson Jan P G, 2005, Eye Contact Lens, V31, P281, DOI 10.1097/01.ICL.0000165280.94927.0D
  • [3] Scanning Acoustic Microscopy for Mapping the Microelastic Properties of Human Corneal Tissue
    Beshtawi, Ithar M.
    Akhtar, Riaz
    Hillarby, M. Chantal
    O'Donnell, Clare
    Zhao, Xuegen
    Brahma, Arun
    Carley, Fiona
    Derby, Brian
    Radhakrishnan, Hema
    [J]. CURRENT EYE RESEARCH, 2013, 38 (04) : 437 - 444
  • [4] Mapping collagen organization in the human cornea: Left and right eyes are structurally distinct
    Boote, C
    Hayes, S
    Abahussin, M
    Meek, KM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) : 901 - 908
  • [5] Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications
    Boote, C
    Dennis, S
    Newton, RH
    Puri, H
    Meek, KM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) : 2941 - 2948
  • [6] Brillouin L, 1922, Ann Phys, V9, P88, DOI [10.1051/anphys/192209170088, DOI 10.1051/ANPHYS/192209170088]
  • [7] Depth-Dependent Corneal Biomechanical Properties in Normal and Keratoconic Subjects by Optical Coherence Elastography
    De Stefano, Vinicius S.
    Ford, Matthew R.
    Seven, Ibrahim
    Dupps, William J., Jr.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (07):
  • [8] Live human assessment of depth-dependent corneal displacements with swept-source optical coherence elastography
    De Stefano, Vinicius S.
    Ford, Matthew R.
    Seven, Ibrahim
    Dupps, William J., Jr.
    [J]. PLOS ONE, 2018, 13 (12):
  • [9] De Stefano Vinicius S, 2017, Int Ophthalmol Clin, V57, P75, DOI 10.1097/IIO.0000000000000172
  • [10] Characterization of cone size and centre in keratoconic corneas
    Eliasy, Ashkan
    Abass, Ahmed
    Lopes, Bernardo T.
    Vinciguerra, Riccardo
    Zhang, Haixia
    Vinciguerra, Paolo
    Ambrosio Jr, Renato
    Roberts, Cynthia J.
    Elsheikh, Ahmed
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2020, 17 (169)