Safety of an esophageal deviator for atrial fibrillation catheter ablation

被引:0
作者
Pereira, Renner [1 ]
Pisani, Cristiano [1 ]
Aiello, Vera [1 ]
Cestari, Idagene [1 ]
Oyama, Helena [1 ]
Santos, Osmar [2 ]
Otubo, Jorge [2 ]
Moura, Daniel [1 ]
Scanavacca, Mauricio [1 ,3 ]
机构
[1] Univ Sao Paulo, Med Sch, Heart Inst, Arrhythmia Unit, Sao Paulo, Brazil
[2] Aeronaut Inst Technol, Dept Mat & Proc, Sao Jose Dos Campos, Brazil
[3] Univ Sao Paulo, Med Sch, Heart Inst, Ave Dr Eneas Carvalho de Aguiar 44, Sao Paulo, Brazil
来源
HEART RHYTHM O2 | 2023年 / 4卷 / 09期
关键词
Atrial fibrillation; Catheter ablation; Complication; Esophageal injury; Esophageal deviator; Safety; DISPLACEMENT; PROTECTION;
D O I
10.1016/j.hroo.2023.07.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Esophageal thermal injury is a complication of atrial fibrillation (AF) ablation, and it can be avoided by esophageal deviation during left atrial posterior wall radiofrequency catheter ablation.OBJECTIVE This study aimed to evaluate the safety of a nitinol-based mechanical esophageal displacement device (MEDD) and its performance.METHODS This preclinical safety study was conducted on 20 pigs, with 10 undergoing radiofrequency AF ablation using the MEDD and 10 serving as a control group under anticoagulation but without radiofrequency application. Esophageal traumatic injuries were classified from 0 to 4 and were grouped as absent (grade 0), minor (grade 1 or 2), moderate (grade 3), or major risk lesions (grade 4) by anatomopathological study. Grades 1 and 2 were considered accept-able. Fluoroscopy was used to measure displacement.RESULTS Five (25%) pigs developed traumatic lesions, 4 with grade 1 and 1 with grade 2 (2-mm superficial ulcer). There was no difference in lesion occurrence between the radiofrequency and control groups (30% and 20%, respectively; P = .43). Under rightward displacement, the right edge moved 23.9 (interquartile range [IQR] 21.3- 26.3) mm and the left edge moved 16.3 (IQR 13.8-18.4) mm (P , .001) from baseline. Under leftward displacement, the right edge moved 13.5 (IQR 10.9-15.3) mm and the left edge moved 16.5 (IQR 12.3-18.5) mm (P = .07). A perforation to the pharyngeal diverticulum occurred in 1 pig, related to an accidental extubation.CONCLUSION In pigs, the MEDD demonstrated safety in relation to esophageal tissue, and successful deviation. Esophageal traumatic injuries were acceptable, but improper manipulation led to pharyngeal lesion.
引用
收藏
页码:565 / 573
页数:9
相关论文
共 22 条
[1]   Esophageal deviation with vacuum suction and mechanical deflection during ablation of atrial fibrillation: First in man evaluation [J].
Aguinaga, Luis ;
Palazzo, Alejandro ;
Bravo, Alejandro ;
Lizarraga, Gabriela ;
Sandoval, Daisy ;
Figueroa, Eduardo ;
Juri, Teresa ;
Daoud, Emile G. ;
Weiss, Raul .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (01) :67-70
[2]  
Ain QU, 2020, Cureus, V12
[3]   Catheter Ablation Versus Medical Therapy for Atrial Fibrillation A Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Asad, Zain Ul Abideen ;
Yousif, Ali ;
Khan, Muhammad Shahzeb ;
Al-Khatib, Sana M. ;
Stavrakis, Stavros .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (09)
[4]   Esophageal Deviation During Atrial Fibrillation Ablation Clinical Experience With a Dedicated Esophageal Balloon Retractor [J].
Bhardwaj, Rahul ;
Naniwadekar, Aditi ;
Whang, William ;
Mittnacht, Alexander J. ;
Palaniswamy, Chandrasekar ;
Koruth, Jacob S. ;
Joshi, Kamal ;
Sofi, Aamir ;
Miller, Marc ;
Choudry, Subbarao ;
Dukkipati, Srinivas R. ;
Reddy, Vivek Y. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (08) :1020-1030
[5]  
Calkins H, 2018, EUROPACE, V20, pE1, DOI [10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
[6]   Mechanical displacement of the esophagus in patients undergoing left atrial ablation of atrial fibrillation [J].
Chugh, Aman ;
Rubenstein, Joe ;
Good, Eric ;
Ebinger, Matthew ;
Jongnarangsin, Krit ;
Fortino, Jackie ;
Bogun, Frank ;
Peosi, Frank, Jr. ;
Oral, Hakan ;
Nostrant, Timothy ;
Morady, Fred .
HEART RHYTHM, 2009, 6 (03) :319-322
[7]   Prevalence and prevention of oesophageal injury during atrial fibrillation ablation: a systematic review and meta-analysis [J].
Ha, Francis J. ;
Han, Hui-Chen ;
Sanders, Prashanthan ;
Teh, Andrew W. ;
O'Donnell, David ;
Farouque, Omar ;
Lim, Han S. .
EUROPACE, 2019, 21 (01) :80-90
[8]   Atrioesophageal Fistula Clinical Presentation, Procedural Characteristics, Diagnostic Investigations, and Treatment Outcomes [J].
Han, Hui-Chen ;
Ha, Francis J. ;
Sanders, Prashanthan ;
Spencer, Ryan ;
Teh, Andrew W. ;
O'Donnell, David ;
Farouque, Omar ;
Lim, Han S. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (11)
[9]   Mechanical esophageal deflection during ablation of atrial fibrillation [J].
Herweg, Bengt ;
Johnson, Nancy ;
Postler, Gilbert ;
Curtis, Anne B. ;
Barold, S. Serge ;
Ilercil, Arzu .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (09) :957-961
[10]   Mechanical Esophageal Displacement During Catheter Ablation for Atrial Fibrillation [J].
Koruth, Jacob S. ;
Reddy, Vivek Y. ;
Miller, Marc A. ;
Patel, Kalpesh K. ;
Coffey, James O. ;
Fischer, Avi ;
Gomes, J. Anthony ;
Dukkipati, Srinivas ;
D'Avila, Andre ;
Mittnacht, Alexander .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (02) :147-154