A Combined Plasmonic and Electrochemical Aptasensor Based on Gold Nanopit Arrays for the Detection of Human Serum Albumin

被引:2
|
作者
Zhu, Ruifeng [1 ,2 ]
Figueroa-Miranda, Gabriela [1 ]
Zhou, Lei [1 ]
Hu, Ziheng [1 ]
Lenyk, Bohdan [1 ,3 ]
Ingebrandt, Sven [2 ]
Offenhaeusser, Andreas [1 ]
Mayer, Dirk [1 ]
机构
[1] Forschungszentrum Julich, Inst Biol Informat Proc, Bioelect IBI 3, D-52428 Julich, Germany
[2] Rhein Westfal TH Aachen, Inst Mat Elect Engn 1, D-52074 Aachen, Germany
[3] Univ Konstanz, Dept Phys, D-78457 Constance, Germany
关键词
gold nanopit arrays; gold nanohole arrays; surface plasmon polaritons; aptasensor; nanoimprint lithography; nanosphere lithography; OPTICAL-TRANSMISSION; SURFACE; APTAMER; PERFORMANCE;
D O I
10.3390/nano13162374
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical and optical platforms are commonly employed in designing biosensors. However, one signal readout can easily lead to inaccuracies due to the effect of nonstandard test procedures, different operators, and experimental environments. We have developed a dual-signal protocol that combined two transducer principles in one aptamer-based biosensor by simultaneously performing electrochemical- and extraordinary optical transmission (EOT)-based plasmonic detection using gold nanopit arrays (AuNpA). Compared with full hole structures, we found that nanopits, that did not fully penetrate the gold film, not only exhibited a better plasmonic bandwidth and refractive index sensitivity both in the finite-difference time-domain simulation and in experiments by shielding the gold/quartz mode but also enlarged the electrochemical active surface area. Therefore, the periodic non-fully penetrating AuNpA were modified with ferrocene-labeled human serum albumin aptamer receptors. The formation of the receptor layer and human serum albumin binding complex induced a conformational change, which resulted in variation in the electron transfer between the electro-active ferrocene units and the AuNpA surface. Simultaneously, the binding event caused a surface plasmon polaritons wavelength shift corresponding to a change in the surface refractive index. Interestingly, although both transducers recorded the same binding process, they led to different limits of detection, dynamic ranges, and sensitivities. The electrochemical transducer showed a dynamic detection range from 1 nM to 600 mu M, while the optical transducer covered high concentrations from 100 mu M to 600 mu M. This study not only provides new insights into the design of plasmonic nanostructures but also potentially opens an exciting avenue for dual-signal disease diagnosis and point-of-care testing applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Plasmonic Biosensor Based on Vertical Arrays of Gold Nanoantennas
    Klinghammer, Stephanie
    Uhlig, Tino
    Patrovsky, Fabian
    Boehm, Matthias
    Schuett, Julian
    Puetz, Nils
    Baraban, Larysa
    Eng, Lukas M.
    Cuniberti, Gianaurelio
    ACS SENSORS, 2018, 3 (07): : 1392 - 1400
  • [42] Au/TiO2 nanorod arrays-based electrochemical aptasensor for ultrasensitive detection of adenosine
    Wang, Xuan
    Qin, Yuanlong
    Zhang, Xinyu
    Leng, Yumin
    Chen, Zhengbo
    MICROCHEMICAL JOURNAL, 2023, 190
  • [43] Plasmonic-enhanced electrochemical detection of volatile biomarkers with gold functionalized TiO2 nanotube arrays
    Dhiman Bhattacharyya
    Pankaj Kumar
    York R.Smith
    Swomitra K.Mohanty
    Mano Misra
    Journal of Materials Science & Technology, 2018, 34 (06) : 905 - 913
  • [44] Plasmonic-enhanced electrochemical detection of volatile biomarkers with gold functionalized TiO2 nanotube arrays
    Bhattacharyya, Dhiman
    Kumar, Pankaj
    Smith, York R.
    Mohanty, Swomitra K.
    Misra, Mano
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2018, 34 (06) : 905 - 913
  • [45] An Electrochemical Immunosensor Based on Gold Nanoparticles Decorated Cobalt Boride Nanosheet Arrays for Detection of Human Chorionic Gonadotropin
    Lu Wen-Bo
    Bao Can-Can
    Wei Ming
    Niu Qiang-Qiang
    Bai Li-Wei
    Cao Xiao-Wei
    Jia Jian-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (12) : 2075 - 2085
  • [46] Gold Nanoparticle-Based Facile Detection of Human Serum Albumin and Its Application as an INHIBIT Logic Gate
    Huang, Zhenzhen
    Wang, Haonan
    Yang, Wensheng
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (17) : 8990 - 8998
  • [47] An electrochemical aptasensor based on AuNRs/AuNWs for sensitive detection of apolipoprotein A-1 (ApoA1) from human serum
    Husna, Raudhatul
    Kurup, Chitra Padmakumari
    Ansari, Mohd Afaque
    Mohd-Naim, Noor Faizah
    Ahmed, Minhaz Uddin
    RSC ADVANCES, 2023, 13 (06) : 3890 - 3898
  • [48] Denatured bovine serum albumin hydrogel–based electrochemical biosensors for detection of IgG
    Huiqing Yang
    Qianqian Hou
    Caifeng Ding
    Microchimica Acta, 2022, 189
  • [49] Fabrication of a Novel and Ultrasensitive Label-Free Electrochemical Aptasensor Based on Gold Nanostructure for Detection of Homocysteine
    Zaimbashi, Reza
    Tajik, Somayeh
    Beitollahi, Hadi
    Torkzadeh-Mahani, Masoud
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [50] Electrochemical Aptasensor Based on Platinum @ Gold Nanowires as Signal Amplifier for Aflatoxin B1 Detection
    Liu J.
    Liu Z.
    Li X.
    Ma Z.
    Science and Technology of Food Industry, 2023, 44 (24) : 294 - 300