A Combined Plasmonic and Electrochemical Aptasensor Based on Gold Nanopit Arrays for the Detection of Human Serum Albumin

被引:2
|
作者
Zhu, Ruifeng [1 ,2 ]
Figueroa-Miranda, Gabriela [1 ]
Zhou, Lei [1 ]
Hu, Ziheng [1 ]
Lenyk, Bohdan [1 ,3 ]
Ingebrandt, Sven [2 ]
Offenhaeusser, Andreas [1 ]
Mayer, Dirk [1 ]
机构
[1] Forschungszentrum Julich, Inst Biol Informat Proc, Bioelect IBI 3, D-52428 Julich, Germany
[2] Rhein Westfal TH Aachen, Inst Mat Elect Engn 1, D-52074 Aachen, Germany
[3] Univ Konstanz, Dept Phys, D-78457 Constance, Germany
关键词
gold nanopit arrays; gold nanohole arrays; surface plasmon polaritons; aptasensor; nanoimprint lithography; nanosphere lithography; OPTICAL-TRANSMISSION; SURFACE; APTAMER; PERFORMANCE;
D O I
10.3390/nano13162374
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical and optical platforms are commonly employed in designing biosensors. However, one signal readout can easily lead to inaccuracies due to the effect of nonstandard test procedures, different operators, and experimental environments. We have developed a dual-signal protocol that combined two transducer principles in one aptamer-based biosensor by simultaneously performing electrochemical- and extraordinary optical transmission (EOT)-based plasmonic detection using gold nanopit arrays (AuNpA). Compared with full hole structures, we found that nanopits, that did not fully penetrate the gold film, not only exhibited a better plasmonic bandwidth and refractive index sensitivity both in the finite-difference time-domain simulation and in experiments by shielding the gold/quartz mode but also enlarged the electrochemical active surface area. Therefore, the periodic non-fully penetrating AuNpA were modified with ferrocene-labeled human serum albumin aptamer receptors. The formation of the receptor layer and human serum albumin binding complex induced a conformational change, which resulted in variation in the electron transfer between the electro-active ferrocene units and the AuNpA surface. Simultaneously, the binding event caused a surface plasmon polaritons wavelength shift corresponding to a change in the surface refractive index. Interestingly, although both transducers recorded the same binding process, they led to different limits of detection, dynamic ranges, and sensitivities. The electrochemical transducer showed a dynamic detection range from 1 nM to 600 mu M, while the optical transducer covered high concentrations from 100 mu M to 600 mu M. This study not only provides new insights into the design of plasmonic nanostructures but also potentially opens an exciting avenue for dual-signal disease diagnosis and point-of-care testing applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Electrochemical Aptasensor Based on ZnO Modified Gold Electrode
    Evtugyn, Gennady
    Cherkina, Uljana
    Porfireva, Anna
    Danzberger, Juergen
    Ebner, Andreas
    Hianik, Tibor
    ELECTROANALYSIS, 2013, 25 (08) : 1855 - 1863
  • [22] Dual sensitive and rapid detection of glycated human serum albumin using a versatile lead/graphene nanocomposite probe as a fluorescence-electrochemical aptasensor
    Putnin, Thitirat
    Waiwinya, Wassa
    Pimalai, Dechnarong
    Chawjiraphan, Wireeya
    Sathirapongsasuti, Nuankanya
    Japrung, Deanpen
    ANALYST, 2021, 146 (13) : 4357 - 4364
  • [23] A graphene aptasensor for biomarker detection in human serum
    Wang, Xuejun
    Zhu, Yibo
    Olsen, Timothy R.
    Sun, Na
    Zhang, Wenjun
    Pei, Renjun
    Lin, Qiao
    ELECTROCHIMICA ACTA, 2018, 290 : 356 - 363
  • [24] Impedimetric aptasensor for tobramycin detection in human serum
    Gonzalez-Fernandez, Eva
    de-los-Santos-Alvarez, Noemi
    Jesus Lobo-Castanon, Maria
    Jose Miranda-Ordieres, Arturo
    Tunon-Blanco, Paulino
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2354 - 2360
  • [25] Electrochemical Impedance Spectroscopy on Interdigitated Gold Microelectrodes for Glycosylated Human Serum Albumin Characterization
    Bohli, Nadra
    Chammem, Hanen
    Meilhac, Olivier
    Mora, Laurence
    Abdelghani, Adnane
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2017, 16 (08) : 676 - 681
  • [26] Fluorescence turn-on detection of human serum albumin based on the assembly of gold nanoclusters and bromocresol green
    Wenxiang Xiao
    Yaoxin Li
    Yinan Xiong
    ZhenCheng Chen
    Hua Li
    Analytical and Bioanalytical Chemistry, 2023, 415 : 3363 - 3374
  • [27] Fluorescence turn-on detection of human serum albumin based on the assembly of gold nanoclusters and bromocresol green
    Xiao, Wenxiang
    Li, Yaoxin
    Xiong, Yinan
    Chen, ZhenCheng
    Li, Hua
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (17) : 3363 - 3374
  • [28] Colorimetric detection of lysozyme based on electrostatic interaction with human serum albumin-modified gold nanoparticles
    Chen, Yi-Ming
    Yu, Cheng-Ju
    Cheng, Tian-Lu
    Tseng, Wei-Lung
    LANGMUIR, 2008, 24 (07) : 3654 - 3660
  • [29] Low fouling electrochemical sensing interfaces based on Bovine serum albumin hydrogel for the detection of protein biomarkers in human serum
    Yu, Xiaohang
    Li, Yang
    Lv, Shaoping
    Zeng, Xianghua
    Luo, Xiliang
    Wang, Peipei
    MICROCHEMICAL JOURNAL, 2024, 199
  • [30] Dual-Transducer Malaria Aptasensor Combining Electrochemical Impedance and Surface Plasmon Polariton Detection on Gold Nanohole Arrays
    Lenyk, Bohdan
    Figueroa-Miranda, Gabriela
    Pavlushko, Ivan
    Lo, Young
    Tanner, Julian A.
    Offenhaeusser, Andreas
    Mayer, Dirk
    CHEMELECTROCHEM, 2020, 7 (22): : 4594 - 4600