A Combined Plasmonic and Electrochemical Aptasensor Based on Gold Nanopit Arrays for the Detection of Human Serum Albumin

被引:2
|
作者
Zhu, Ruifeng [1 ,2 ]
Figueroa-Miranda, Gabriela [1 ]
Zhou, Lei [1 ]
Hu, Ziheng [1 ]
Lenyk, Bohdan [1 ,3 ]
Ingebrandt, Sven [2 ]
Offenhaeusser, Andreas [1 ]
Mayer, Dirk [1 ]
机构
[1] Forschungszentrum Julich, Inst Biol Informat Proc, Bioelect IBI 3, D-52428 Julich, Germany
[2] Rhein Westfal TH Aachen, Inst Mat Elect Engn 1, D-52074 Aachen, Germany
[3] Univ Konstanz, Dept Phys, D-78457 Constance, Germany
关键词
gold nanopit arrays; gold nanohole arrays; surface plasmon polaritons; aptasensor; nanoimprint lithography; nanosphere lithography; OPTICAL-TRANSMISSION; SURFACE; APTAMER; PERFORMANCE;
D O I
10.3390/nano13162374
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical and optical platforms are commonly employed in designing biosensors. However, one signal readout can easily lead to inaccuracies due to the effect of nonstandard test procedures, different operators, and experimental environments. We have developed a dual-signal protocol that combined two transducer principles in one aptamer-based biosensor by simultaneously performing electrochemical- and extraordinary optical transmission (EOT)-based plasmonic detection using gold nanopit arrays (AuNpA). Compared with full hole structures, we found that nanopits, that did not fully penetrate the gold film, not only exhibited a better plasmonic bandwidth and refractive index sensitivity both in the finite-difference time-domain simulation and in experiments by shielding the gold/quartz mode but also enlarged the electrochemical active surface area. Therefore, the periodic non-fully penetrating AuNpA were modified with ferrocene-labeled human serum albumin aptamer receptors. The formation of the receptor layer and human serum albumin binding complex induced a conformational change, which resulted in variation in the electron transfer between the electro-active ferrocene units and the AuNpA surface. Simultaneously, the binding event caused a surface plasmon polaritons wavelength shift corresponding to a change in the surface refractive index. Interestingly, although both transducers recorded the same binding process, they led to different limits of detection, dynamic ranges, and sensitivities. The electrochemical transducer showed a dynamic detection range from 1 nM to 600 mu M, while the optical transducer covered high concentrations from 100 mu M to 600 mu M. This study not only provides new insights into the design of plasmonic nanostructures but also potentially opens an exciting avenue for dual-signal disease diagnosis and point-of-care testing applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Flexible multielectrode arrays based electrochemical aptasensor for glycated human serum albumin detection
    Zhou, Lei
    Figueroa-Miranda, Gabriela
    Chen, Song
    Neis, Marc
    Hu, Ziheng
    Zhu, Ruifeng
    Li, Yaqi
    Proempers, Michael
    Offenhaeusser, Andreas
    Mayer, Dirk
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 386
  • [2] Adsorption of human serum albumin onto gold: a combined electrochemical and ellipsometric study
    Ying, PQ
    Viana, AS
    Abrantes, LM
    Jin, G
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2004, 279 (01) : 95 - 99
  • [3] Sensitive electrochemical thrombin aptasensor based on gold disk microelectrode arrays
    Bai, Huei-Yu
    Javier Del Campo, F.
    Tsai, Yu-Chen
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 17 - 22
  • [4] Polydopamine Nanoparticles Functionalized Electrochemical DNA Aptasensor for Serum Glycated Albumin Detection
    Maraming, Pornsuda
    Aye, Nang Noon Shean
    Boonsiri, Patcharee
    Daduang, Sakda
    Buhome, Onanong
    Daduang, Jureerut
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (22)
  • [5] A nanoporous gold-based electrochemical aptasensor for sensitive detection of cocaine
    Tavakkoli, Nahid
    Soltani, Nasrin
    Mohammadi, Fatemeh
    RSC ADVANCES, 2019, 9 (25) : 14296 - 14301
  • [6] A sensitive nanoporous gold-based electrochemical aptasensor for thrombin detection
    Qiu, Huajun
    Sun, Yanli
    Huang, Xirong
    Qu, Yinbo
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (01) : 304 - 308
  • [7] An antifouling electrochemical aptasensor based on hyaluronic acid functionalized polydopamine for thrombin detection in human serum
    Sun, Jiafeng
    Wang, Guixiang
    Cheng, Hao
    Han, Yinfeng
    Li, Qun
    Jiang, Cheng
    BIOELECTROCHEMISTRY, 2022, 145
  • [8] An antifouling electrochemical aptasensor based on hyaluronic acid functionalized polydopamine for thrombin detection in human serum
    Sun, Jiafeng
    Wang, Guixiang
    Cheng, Hao
    Han, Yinfeng
    Li, Qun
    Jiang, Cheng
    Bioelectrochemistry, 2022, 145
  • [9] A highly sensitive gold nanoparticle-based electrochemical aptasensor for theophylline detection
    Chen, Xifeng
    Guo, Zhenzhen
    Tang, Yuguo
    Shen, Ying
    Miao, Peng
    ANALYTICA CHIMICA ACTA, 2018, 999 : 54 - 59
  • [10] An electrochemical aptasensor based on gold@polypyrrole composites for detection of lead ions
    Jina Ding
    Yang liu
    Dongwei Zhang
    Minglei Yu
    Xuejia Zhan
    Dan Zhang
    Pei Zhou
    Microchimica Acta, 2018, 185