Comprehensive analysis of melting enhancement by circular Y-shaped fins in a vertical shell-and-tube heat storage system

被引:22
作者
Ben Khedher, Nidhal [1 ,2 ]
Togun, Hussein [3 ]
Abed, Azher M. M. [4 ]
Mohammed, Hayder I. I. [5 ]
Mahdi, Jasim M. M.
Ibrahem, Raed Khalid [6 ]
Yaici, Wahiba [7 ]
Talebizadehsardari, Pouyan [8 ,10 ]
Keshmiri, Amir [9 ]
机构
[1] Univ Hail, Coll Engn, Dept Mech Engn, Hail City, Saudi Arabia
[2] Univ Monastir, Natl Sch Engn Monastir, Lab Thermal & Energet Syst Studies LESTE, Monastir, Tunisia
[3] Univ Thi Qar, Coll Engn, Dept Biomed Engn, Thi Qar, Iraq
[4] Al Mustaqbal Univ Coll, Air Conditioning & Refrigerat Tech Engn Dept, Babylon, Iraq
[5] Univ Garmian, Coll Educ, Dept Phys, Kalar, Iraq
[6] Al Farahidi Univ, Dept Med Instrumentat Engn, Baghdad, Iraq
[7] Nat Resources Canada, CanmetENERGY Res Ctr, 1 Haanel Dr, Ottawa, ON, Canada
[8] Univ Nottingham, Fac Engn, Nottingham, England
[9] Univ Manchester, Sch Engn, Manchester, England
[10] Univ Nottingham, Univ Pk, Nottingham NG7 2RD, England
基金
英国工程与自然科学研究理事会;
关键词
Circular Y-shaped fins; PCM; thermal energy storage; double-pipe heat exchanger; charging; THERMAL-ENERGY STORAGE; PHASE-CHANGE-MATERIALS; RENEWABLE ENERGY; TRIPLEX-TUBE; PCM; PERFORMANCE; SIMULATION; SALTS;
D O I
10.1080/19942060.2023.2227682
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To overcome the weak thermal conduction of the phase change materials (PCM), This investigation aims to study the effect of circular Y-shaped fins added to a two-pipe latent heat-saving unit compared with conventional circular fins. The system is placed in a straight-up orientation, and the PCM is located in the annulus, whereas hot water is moved inside the internal tube to charge the phase change material (PCM) with a phase change point of 35 & DEG;C. Different independent geometric factors of the fins involving the length of the stem and angle of the tributaries to the horizontal line and the number of Y-shaped fins are analysed. The impact of the working fluid's Reynolds number and temperature (as the input parameters) are evaluated as a sensitivity analysis to control the output (melting time and rate). The results show that increasing the height and number of the fins and reducing the angles of the tributaries results in higher performance of the system. For the optimal case, increasing the Reynolds number of the working fluid from 500 to 2000 results in 31% reductions in the melting time. Moreover, raising the working fluid's temperature from 45 & DEG; to 55 & DEG; reduces the melting time by & SIM;44%.
引用
收藏
页数:25
相关论文
共 57 条
[1]   RETRACTED: Improving the melting performance in a triple-pipe latent heat storage system using hemispherical and quarter-spherical fins with a staggered arrangement (Retracted Article) [J].
Abed, Azher M. ;
Mohammed, Hayder I. ;
Patra, Indrajit ;
Mahdi, Jasim M. ;
Arshad, Adeel ;
Sivaraman, Ramaswamy ;
Ibrahem, Raed Khalid ;
Al-Qrimli, Fadhil Abbas ;
Dhahbi, Sami ;
Talebizadehsardari, Pouyan .
FRONTIERS IN CHEMISTRY, 2022, 10
[2]   Renewable Energy Systems to Enhance Buildings Thermal Performance and Decrease Construction Costs [J].
Albatayneh, Aiman ;
Alterman, Dariusz ;
Page, Adrian ;
Moghtaderi, Behdad .
CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 :312-317
[3]   Numerical evaluation of a triple concentric-tube latent heat thermal energy storage [J].
Basal, Birol ;
Unal, Ahmet .
SOLAR ENERGY, 2013, 92 :196-205
[4]   A review of numerical studies on solar collectors integrated with latent heat storage systems employing fins or nanoparticles [J].
Bazri, Shahab ;
Badruddin, Irfan Anjum ;
Naghavi, Mohammad Sajad ;
Bahiraei, Mehdi .
RENEWABLE ENERGY, 2018, 118 :761-778
[5]   Effect of Y-shaped fins on the performance of shell-and-tube thermal energy storage unit [J].
Belazreg, Abdeldjalil ;
Abderrahmane, Aissa ;
Qasem, Naef A. A. ;
Sene, Ndolane ;
Mohammed, Sahnoun ;
Younis, Obai ;
Guedri, Kamel ;
Nasajpour-Esfahani, Navid ;
Toghraie, Davood .
CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
[6]   Renewable energy for a clean and sustainable future [J].
Bilgen, S ;
Kaygusuz, K ;
Sari, A .
ENERGY SOURCES, 2004, 26 (12) :1119-1129
[7]  
Boetcher S.K.S., 2022, Solid-Liquid Thermal Energy Storage, P243, DOI [10.1201/9781003213260-11, DOI 10.1201/9781003213260-11]
[8]  
BRENT AD, 1988, NUMER HEAT TRANSFER, V13, P297, DOI 10.1080/10407788808913615
[9]   Renewable energy today and tomorrow [J].
Bull, SR .
PROCEEDINGS OF THE IEEE, 2001, 89 (08) :1216-1226
[10]   Numerical and experimental investigation on latent thermal energy storage system with spiral coil tube and paraffin/expanded graphite composite PCM [J].
Chen, Caixing ;
Zhang, Hua ;
Gao, Xuenong ;
Xu, Tao ;
Fang, Yutang ;
Zhang, Zhengguo .
ENERGY CONVERSION AND MANAGEMENT, 2016, 126 :889-897