CO2 concentration as an indicator of indoor ventilation performance to control airborne transmission of SARS-CoV-2

被引:10
|
作者
Park, Sowoo [1 ]
Song, Doosam [2 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 16419, South Korea
[2] Sungkyunkwan Univ, Sch Civil Architectural Eng & Landscape Architect, Suwon 16419, South Korea
关键词
SARS-CoV-2; Airborne transmission; Probability of infection; Rebreathed fraction; CO; 2; concentration; RISK;
D O I
10.1016/j.jiph.2023.05.011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The Wells-Riley equation has been extensively used to quantify the infection risk of airborne transmission indoors. This equation is difficult to apply to actual conditions because it requires measurement of the outdoor air supply rate, which vary with time and are difficult to quantify. The method of determining the fraction of inhaled air that has been exhaled previously by someone in a building using a CO2 concentration measurement can solve the limitations of the existing method. Using this method, the indoor CO2 concentration threshold can be determined to keep the risk of infection below certain conditions.Methods: Based on the calculation of the rebreathed fraction, an appropriate mean indoor CO2 concentration and required air exchange rate to control SARS-CoV-2 airborne transmission was calculated. The number of indoor occupants, ventilation rate, and the deposition and inactivation rates of the virus-laden aerosols were considered. The application of the proposed indoor CO2 concentration-based infection rate control was investigated through case studies in school classrooms and restaurants.Results: In a typical school classroom environment with 20-25 occupants and an exposure time of 6-8 h, the average indoor CO2 concentration should be kept below 700 ppm to control the risk of airborne infection indoors. The ASHRAE recommended ventilation rate is sufficient when wearing a mask in classrooms. For a typical restaurant with 50-100 occupants and an exposure time of 2-3 h, the average indoor CO2 concentration should be kept below about 900 ppm. Residence time in the restaurant had a significant effect on the acceptable CO2 concentration.Conclusion: Given the conditions of the occupancy environment, it is possible to determine an indoor CO2 concentration threshold, and keeping the CO2 concentration lower than a certain threshold could help reduce the risk of COVID-19 infection.(c) 2023 Published by Elsevier Ltd on behalf of King Saud Bin Abdulaziz University for Health Sciences. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1037 / 1044
页数:8
相关论文
共 50 条
  • [21] Insufficient ventilation led to a probable long-range airborne transmission of SARS-CoV-2 on two buses
    Ou, Cuiyun
    Hu, Shixiong
    Luo, Kaiwei
    Yang, Hongyu
    Hang, Jian
    Cheng, Pan
    Hai, Zheng
    Xiao, Shanliang
    Qian, Hua
    Xiao, Shenglan
    Jing, Xinping
    Xie, Zhengshen
    Ling, Hong
    Liu, Li
    Gao, Lidong
    Deng, Qihong
    Cowling, Benjamin J.
    Li, Yuguo
    BUILDING AND ENVIRONMENT, 2022, 207
  • [22] The vaccination threshold for SARS-CoV-2 depends on the indoor setting and room ventilation
    Mikszewski, A.
    Stabile, L.
    Buonanno, G.
    Morawska, L.
    BMC INFECTIOUS DISEASES, 2021, 21 (01)
  • [23] The vaccination threshold for SARS-CoV-2 depends on the indoor setting and room ventilation
    A. Mikszewski
    L. Stabile
    G. Buonanno
    L. Morawska
    BMC Infectious Diseases, 21
  • [24] Active Air Monitoring for Understanding the Ventilation and Infection Risks of SARS-CoV-2 Transmission in Public Indoor Spaces
    Kumar, Prashant
    Kalaiarasan, Gopinath
    Bhagat, Rajesh K.
    Mumby, Sharon
    Adcock, Ian M.
    Porter, Alexandra E.
    Ransome, Emma
    Abubakar-Waziri, Hisham
    Bhavsar, Pankaj
    Shishodia, Swasti
    Dilliway, Claire
    Fang, Fangxin
    Pain, Christopher C.
    Chung, Kian Fan
    ATMOSPHERE, 2022, 13 (12)
  • [25] Assessment of SARS-CoV-2 airborne infection transmission risk in public buses
    Bertone, M.
    Mikszewski, A.
    Stabile, L.
    Riccio, G.
    Cortellessa, G.
    d'Ambrosio, F. R.
    Papa, V.
    Morawska, L.
    Buonanno, G.
    GEOSCIENCE FRONTIERS, 2022, 13 (06)
  • [26] The SARS-COV-2 outbreak around the Amazon rainforest: The relevance of the airborne transmission
    Crema, Edilson
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 759
  • [27] A Letter about the Airborne Transmission of SARS-CoV-2 Based on the Current Evidence
    Hadei, Mostafa
    Hopke, Philip K.
    Jonidi, Ahmad
    Shahsavani, Abbas
    AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (05) : 911 - 914
  • [28] SARS-CoV-2 airborne infection probability estimated by using indoor carbon dioxide
    Iwamura, Narumichi
    Tsutsumi, Kanako
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (32) : 79227 - 79240
  • [29] SARS-CoV-2 airborne infection probability estimated by using indoor carbon dioxide
    Narumichi Iwamura
    Kanako Tsutsumi
    Environmental Science and Pollution Research, 2023, 30 : 79227 - 79240
  • [30] Systematic Review of the Key Factors Influencing the Indoor Airborne Spread of SARS-CoV-2
    de Crane D'Heysselaer, Simon
    Parisi, Gianni
    Lisson, Maxime
    Bruyere, Olivier
    Donneau, Anne-Francoise
    Fontaine, Sebastien
    Gillet, Laurent
    Bureau, Fabrice
    Darcis, Gilles
    Thiry, Etienne
    Ducatez, Mariette
    Snoeck, Chantal J.
    Zientara, Stephan
    Haddad, Nadia
    Humblet, Marie-France
    Ludwig-Begall, Louisa F.
    Daube, Georges
    Thiry, Damien
    Misset, Benoit
    Lambermont, Bernard
    Tandjaoui-Lambiotte, Yacine
    Zahar, Jean-Raph
    Sartor, Kevin
    Noel, Catherine
    Saegerman, Claude
    Haubruge, Eric
    PATHOGENS, 2023, 12 (03):