CO2 concentration as an indicator of indoor ventilation performance to control airborne transmission of SARS-CoV-2

被引:10
|
作者
Park, Sowoo [1 ]
Song, Doosam [2 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 16419, South Korea
[2] Sungkyunkwan Univ, Sch Civil Architectural Eng & Landscape Architect, Suwon 16419, South Korea
关键词
SARS-CoV-2; Airborne transmission; Probability of infection; Rebreathed fraction; CO; 2; concentration; RISK;
D O I
10.1016/j.jiph.2023.05.011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The Wells-Riley equation has been extensively used to quantify the infection risk of airborne transmission indoors. This equation is difficult to apply to actual conditions because it requires measurement of the outdoor air supply rate, which vary with time and are difficult to quantify. The method of determining the fraction of inhaled air that has been exhaled previously by someone in a building using a CO2 concentration measurement can solve the limitations of the existing method. Using this method, the indoor CO2 concentration threshold can be determined to keep the risk of infection below certain conditions.Methods: Based on the calculation of the rebreathed fraction, an appropriate mean indoor CO2 concentration and required air exchange rate to control SARS-CoV-2 airborne transmission was calculated. The number of indoor occupants, ventilation rate, and the deposition and inactivation rates of the virus-laden aerosols were considered. The application of the proposed indoor CO2 concentration-based infection rate control was investigated through case studies in school classrooms and restaurants.Results: In a typical school classroom environment with 20-25 occupants and an exposure time of 6-8 h, the average indoor CO2 concentration should be kept below 700 ppm to control the risk of airborne infection indoors. The ASHRAE recommended ventilation rate is sufficient when wearing a mask in classrooms. For a typical restaurant with 50-100 occupants and an exposure time of 2-3 h, the average indoor CO2 concentration should be kept below about 900 ppm. Residence time in the restaurant had a significant effect on the acceptable CO2 concentration.Conclusion: Given the conditions of the occupancy environment, it is possible to determine an indoor CO2 concentration threshold, and keeping the CO2 concentration lower than a certain threshold could help reduce the risk of COVID-19 infection.(c) 2023 Published by Elsevier Ltd on behalf of King Saud Bin Abdulaziz University for Health Sciences. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1037 / 1044
页数:8
相关论文
共 50 条
  • [1] On airborne transmission and control of SARS-Cov-2
    Yao, Maosheng
    Zhang, Lu
    Ma, Jianxin
    Zhou, Lian
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 731
  • [2] Graphical-mathematical model to estimate CO2 concentration level as an indicator of SARS-CoV-2 transmission
    Razura-Carmona, F. F.
    Navidad-Murrieta, M. S.
    Barajas-Carrillo, V. W.
    Covantes- Rosales, C. E.
    Diaz-Resendiz, K. J. G.
    Toledo-Ibarra, G. A.
    Ventura-Ramon, G. H.
    Ojeda-Duran, A. J.
    Casas-Rodriguez, J. O.
    Giron-Perez, M. I.
    REVISTA BIO CIENCIAS, 2023, 10
  • [3] Transmission of SARS-CoV-2 Indoor and Outdoor Environments
    Xu, Xueli
    Zhang, Jing
    Zhu, Liting
    Huang, Qiansheng
    ATMOSPHERE, 2021, 12 (12)
  • [4] Ventilation concepts in schools for the prevention of transmission of highly infectious viruses (SARS-CoV-2) by aerosols in indoor air
    Birmili, Wolfram
    Selinka, Hans-Christoph
    Moriske, Heinz-Joern
    Daniels, Anja
    Straff, Wolfgang
    BUNDESGESUNDHEITSBLATT-GESUNDHEITSFORSCHUNG-GESUNDHEITSSCHUTZ, 2021, 64 (12) : 1570 - 1580
  • [5] Clearing the air about airborne transmission of SARS-CoV-2
    Atiyani, R.
    Mustafa, S.
    Alsari, S.
    Darwish, A.
    Janahi, E. M.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2021, 25 (21) : 6745 - 6766
  • [6] Modeling the Airborne Transmission of SARS-CoV-2 in Public Transport
    Matheis, Christina
    Norrefeldt, Victor
    Will, Harald
    Herrmann, Tobias
    Noethlichs, Ben
    Eckhardt, Michael
    Stiebritz, Andre
    Jansson, Mattias
    Schoen, Martin
    ATMOSPHERE, 2022, 13 (03)
  • [7] Airborne transmission of the Delta variant of SARS-CoV-2 in an auditorium
    Huang, Jianxiang
    Hao, Tongping
    Liu, Xiao
    Jones, Phil
    Ou, Cuiyun
    Liang, Weihui
    Liu, Fuqiang
    BUILDING AND ENVIRONMENT, 2022, 219
  • [8] Airborne concentrations of SARS-CoV-2 in indoor community environments in Italy
    Marianna Conte
    Matteo Feltracco
    Daniela Chirizzi
    Sara Trabucco
    Adelaide Dinoi
    Elena Gregoris
    Elena Barbaro
    Gianfranco La Bella
    Giuseppina Ciccarese
    Franco Belosi
    Giovanna La Salandra
    Andrea Gambaro
    Daniele Contini
    Environmental Science and Pollution Research, 2022, 29 : 13905 - 13916
  • [9] Airborne concentrations of SARS-CoV-2 in indoor community environments in Italy
    Conte, Marianna
    Feltracco, Matteo
    Chirizzi, Daniela
    Trabucco, Sara
    Dinoi, Adelaide
    Gregoris, Elena
    Barbaro, Elena
    La Bella, Gianfranco
    Ciccarese, Giuseppina
    Belosi, Franco
    La Salandra, Giovanna
    Gambaro, Andrea
    Contini, Daniele
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (10) : 13905 - 13916
  • [10] Indoor aerosol science aspects of SARS-CoV-2 transmission
    Nazaroff, William W.
    INDOOR AIR, 2022, 32 (01)