Videolaryngoscopy vs. flexible fibrescopy for tracheal intubation in patients with cervical spine immobilisation: a randomised controlled trial

被引:7
|
作者
Choi, S. [1 ]
Yoo, H. K. [1 ]
Shin, K. W. [1 ]
Kim, Y. J. [1 ]
Yoon, H. K. [1 ]
Park, H. P. [1 ]
Oh, H. [1 ]
机构
[1] Seoul Natl Univ Hosp, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
关键词
cervical collar; cervical spine immobilisation; flexible fibrescope; tracheal intubation; videolaryngoscope; ENDOTRACHEAL INTUBATION; FIBEROPTIC INTUBATION; ROCURONIUM BROMIDE; CORD-INJURY; SUCCINYLCHOLINE; AIRTRAQ(R); ORG-9426; AIRWAY;
D O I
10.1111/anae.16035
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In patients with cervical spine immobilisation, tracheal intubation devices other than a direct laryngoscope are frequently used to facilitate tracheal intubation and avoid related complications. In this randomised controlled trial, we compared videolaryngoscopic and fibrescopic tracheal intubation in patients with a cervical collar. Tracheal intubation was performed using either a videolaryngoscope with a non-channelled Macintosh blade (n = 166) or a flexible fibrescope (n = 164) in patients having elective cervical spine surgery whose neck was immobilised with a cervical collar to simulate a difficult airway. The primary outcome was the first attempt success rate of tracheal intubation. Secondary outcomes were the overall success rate of tracheal intubation; time to tracheal intubation; use of additional airway manoeuvres; and incidence and severity of tracheal intubation-related airway complications. First attempt success rate was higher in the videolaryngoscope group than in the fibrescope group (164/166 (98.8%) vs. 149/164 (90.9%), p = 0.003). Tracheal intubation was successful within three attempts in all patients. Median (IQR [range]) time to tracheal intubation was shorter (50.0 (41.0-72.0 [25.0-170.0]) s vs. 81.0 (65.0-107.0 [24.0-178.0]) s, p < 0.001) and additional airway manoeuvres were less frequent (30/166 (18.1%) vs. 91/164 (55.5%), p < 0.001) in the videolaryngoscope group compared with the fibrescope group. The incidence and severity of intubation-related airway complications were not different between the two groups. When performing tracheal intubation in patients with a cervical collar, videolaryngoscopy with a non-channelled Macintosh blade was superior to flexible fibrescopy.
引用
收藏
页码:970 / 978
页数:9
相关论文
共 50 条
  • [1] Flexible nasal bronchoscopy vs. Airtraq® videolaryngoscopy for awake tracheal intubation: a randomised controlled non-inferiority study
    Kamga, H.
    Frugier, A.
    Boutros, M.
    Bourges, J.
    Doublet, T.
    Parienti, J. J.
    ANAESTHESIA, 2023, 78 (08) : 963 - 969
  • [2] GlideScope versus D-blade for tracheal intubation in cervical spine patients: A randomised controlled trial
    Kumar, Dinesh
    Gombar, Satinder
    Ahuja, Vanita
    Malhotra, Arvind
    Gupta, Shruti
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (07) : 544 - 550
  • [3] A comparison of conventional tube and EndoFlex tube for tracheal intubation in patients with a cervical spine immobilisation
    Ewelina Gaszynska
    Michal Stankiewicz-Rudnicki
    Andrzej Wieczorek
    Tomasz Gaszynski
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 21
  • [4] A comparison of conventional tube and EndoFlex tube for tracheal intubation in patients with a cervical spine immobilisation
    Gaszynska, Ewelina
    Stankiewicz-Rudnicki, Michal
    Wieczorek, Andrzej
    Gaszynski, Tomasz
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2013, 21
  • [5] Learning tracheal intubation with a hyperangulated videolaryngoscopy blade: sub-analysis of a randomised controlled trial
    Ott, Sascha
    Mueller-Wirtz, Lukas M.
    Bustamante, Sergio
    Roessler, Julian
    Skubas, Nikolaos J.
    Shah, Karan
    Sessler, Daniel I.
    Turan, Alparslan
    Ruetzler, Kurt
    ANAESTHESIA, 2025, 80 (04) : 395 - 403
  • [6] Evaluation of the GlideScope® for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar
    Bathory, I.
    Frascarolo, P.
    Kern, C.
    Schoettker, P.
    ANAESTHESIA, 2009, 64 (12) : 1337 - 1341
  • [7] Effectiveness of intubation devices in patients with cervical spine immobilisation: a systematic review and network meta-analysis
    Singleton, Barry N.
    Morris, Fiachra K.
    Yet, Barbaros
    Buggy, Donal J.
    Perkins, Zane B.
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 126 (05) : 1055 - 1066
  • [8] Videolaryngoscopy vs. fibreoptic bronchoscopy for awake tracheal intubation: a systematic review and meta-analysis
    Alhomary, M.
    Ramadan, E.
    Curran, E.
    Walsh, S. R.
    ANAESTHESIA, 2018, 73 (09) : 1151 - 1161
  • [9] A prospective randomised study of a rigid video-stylet vs. conventional lightwand intubation in cervical spine-immobilised patients
    Seo, H.
    Kim, E.
    Son, J. D.
    Ji, S.
    Min, S. W.
    Park, H. P.
    ANAESTHESIA, 2016, 71 (11) : 1341 - 1346
  • [10] Comparison of BlockBuster® Laryngeal Mask Airway, King Vision® Video Laryngoscope, and flexible intubation scope for orotracheal intubation in adult patients with simulated immobilised cervical spine: A randomised controlled trial
    Sinha, Neha
    Bhat, Kharat
    Khanuja, Samiksha
    Gupta, Mahima
    Wadhwani, Megha
    Panjiar, Pratibha
    INDIAN JOURNAL OF ANAESTHESIA, 2025, 69 (03) : 296 - 301