The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study

被引:7
|
作者
Tonin, Bruna S. H. [1 ]
Fu, Jing [2 ]
He, Yiting [3 ]
Ye, Ning [4 ]
Chew, Hooi Pin [4 ]
Fok, Alex [4 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, Ribeirao Preto, SP, Brazil
[2] Qingdao Univ, Sch Stomatol, Dept Prosthodont, Affiliated Hosp, Qingdao, Peoples R China
[3] Sun Yat Sen Univ, Hosp Stomatol, Dept Prosthodont, Guangdong Prov Key Lab Stomatol, Guangzhou, Guangdong, Peoples R China
[4] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN 55455 USA
关键词
Finite element analysis; Bending moments; Implant -supported dental prosthesis; Prosthodontics; Computer -aided design; Computer -assisted manufacture; LOAD FATIGUE PERFORMANCE; ALL-CERAMIC CROWNS; ZIRCONIA ABUTMENTS; STRESS-DISTRIBUTION; BENDING MOMENTS; TITANIUM; RESTORATIONS; CONNECTIONS; FAILURE;
D O I
10.1016/j.jmbbm.2023.105847
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study aimed to evaluate the stress distribution and microgap formation in implant assemblies with conical abutments made of different materials under an oblique load.Materials and methods: The mechanical behavior of an implant assembly with a titanium abutment was analyzed and compared with that of an assembly with a Y-TZP abutment using finite element analysis (FEA). A torque of 20 Ncm was first applied to the abutment screw, followed by oblique loads of 10 N-280 N applied to the prosthesis placed on the implant. The maximum stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated.Results: No significant difference in stress distribution between the two cases was observed, with the stresses being mainly concentrated at the top half of the screw (the predicted maximum von Mises stress was approxi-mately 1200 MPa at 280 N). The area in contact at the implant-to-abutment interface decreased with increasing load for both abutments, with the critical load for bridging the internal implant space being roughly 140 N. The maximum gap size being was approximately 470 mu m with either abutment.Conclusion: There was no significant difference in the stress distribution or microgap formed between implant assemblies with titanium and Y-TZP abutments having an internal conical connection.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effect of Different Customized Abutment Types on Stress Distribution in Implant-Supported Single Crown: A 3D Finite Element Analysis
    Pumnil, Suphakrit
    Rungsiyakull, Pimduen
    Rungsiyakull, Chaiy
    Elsaka, Shaymaa
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : E2 - E11
  • [2] The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis
    Ausiello, Pietro
    Mendes Tribst, Joao Paulo
    Ventre, Maurizio
    Salvati, Enrico
    di Lauro, Alessandro E.
    Martorelli, Massimo
    Lanzotti, Antonio
    Watts, David C.
    DENTAL MATERIALS, 2021, 37 (11) : 1688 - 1697
  • [3] Effects of abutment screw preload in two implant connection systems: A 3D finite element study
    Jung, Won-kyung
    Lee, Won-sup
    Kwon, Ho-Beom
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05) : 474.e1 - 474.e8
  • [4] Effect of Marginal Bone Integrity and Aftermarket Abutment Screws on Dental Implant Systems-A Preliminary Study with Finite Element Method
    Wu, Yu-Ling
    Tsai, Ming-Hsu
    Chen, Hung-Shyong
    Lin, Ching-Ping
    Wu, Aaron Yu-Jen
    MATERIALS, 2022, 15 (17)
  • [5] Effect of material and dimensions on the mechanical behavior of a dental implant
    Hedia, Hassan S.
    Najjar, Ismail M. R.
    Fouda, Noha
    Al-Thobiani, Fisal W.
    Timraz, Hattan A.
    MATERIALS TESTING, 2020, 62 (08) : 775 - 782
  • [6] Effect of implant-abutment connections with peri-implant bone defect models under removal torque force: A 3D finite element analysis
    Corekci, Ahu Uraz
    Isler, Sila Cagri
    Sengul, Janset
    Guler, Berceste
    Ozdemir, Yucel
    Ozbay, Deniz
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 (04): : 358 - 364
  • [7] Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading
    Mishra, Manish
    Ozawa, Shogo
    Masuda, Tatsuhiko
    Yoshioka, Fumi
    Tanaka, Yoshinobu
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (03) : 140 - 144
  • [8] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [9] Effect of abutment type and creep behavior on the mechanical properties of implant restorations in the anterior region: A finite element analysis
    Anniwaer, Annikaer
    Yin, Zhengrong
    Zhu, Jiakang
    Huang, Cui
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 : 93 - 102
  • [10] Influence of Framework Material and Abutment Configuration on Fatigue Performance in Dental Implant Systems: A Finite Element Analysis
    Erdogdu, Meryem
    Demirel, Mehmet Goekberkkaan
    Mohammadi, Reza
    Guentekin, Neslihan
    Chaleshtori, Masoud Ghanbarzadeh
    MEDICINA-LITHUANIA, 2024, 60 (09):