Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)

被引:5
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
机构
[1] Royal Commiss Jubail & Yanbu, Jubail Tech Inst, Dept Mech Skills, Jubail Ind City, Saudi Arabia
关键词
Heat exchanger; Tube inspection; Eddy current testing; Retubing; Maintenance; CORROSION; TUBE; INSPECTION; PERFORMANCE; EROSION; NDE;
D O I
10.1007/s11668-023-01746-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Shell and tube heat exchangers are widely used in the oil and gas, petrochemical and nuclear power sectors. The most important aspect of the turnaround is the routine testing and inspection of the in-service heat exchanger. Heat exchangers in use are the primary cause of tube flaws such as pitting, corrosion, erosion, fretting corrosion, crevice corrosion, stress corrosion cracking, wear, galvanic corrosion, fatigue cracking, microbiologically influenced corrosion, and so forth. For research, a seamless nickel-iron-chromium alloy-tubed SB 163 (UNS 8810) heat exchanger was taken. The total number of tubes that need to be inspected is 286 tubes with a specification of 19.05 mm OD x 2.11 mm thickness x 5000 mm length. From the different advanced NDT techniques, the eddy current testing (ECT) was chosen for inspection since it has become one of the most popular NDT methods for locating discontinuities in heat exchanger tubes. A standard calibration tube was used to calibrate the system's response and set the sensitivity. During the inspection, the ECT probe was inserted from the below side up to the other end and collected while pulling the probe from the tube. Inspection data were recorded for the length of each tube. All indications were assessed, and defects were categorized as different extents of wall thickness loss after inspection. The inspection report shows how many tubes were found defective and need to be plugged or removed (retubing). From the inspection data (the result of statistics), defects like corrosion, pitting, wall loss, wear, etc., that resulted in notable material loss were identified. Inspection data also summarized where the defects were located (like between the first baffle and the second baffle) and are helpful for further research. After analysis using ECT reports, the defective tubes were categorized according to their defect percentage and location, which helps to do retubing effectively by avoiding the 100% retubing concept.
引用
收藏
页码:1898 / 1906
页数:9
相关论文
共 50 条
  • [41] Applicability of Eddy Current Testing to the Evaluation of Electric Wire
    Akagawa, Junichi
    Katsumata, Ryosuke
    Maeda, Kotaro
    Matsumoto, Yoshihiro
    Harada, Yutaka
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XVII), 2014, 39 : 165 - 172
  • [42] Microtexture Region Segmentation Using Matching Component Analysis Applied to Eddy Current Testing Data
    Homa, Laura
    Lorenzo, Nick
    Cherry, Matthew
    Wertz, John
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2023, 42 (02)
  • [43] Microtexture Region Segmentation using Matching Component Analysis Applied to Eddy Current Testing Data
    Homa, Laura
    Wertz, John
    Cherry, Matthew
    SIGNAL PROCESSING, SENSOR/INFORMATION FUSION, AND TARGET RECOGNITION XXXII, 2023, 12547
  • [44] Performance Analysis of Counter Current Flow Plate Type Heat Exchanger Using Immiscible System
    Kannadasan, T.
    Thirumarimurugan, M.
    Gopalakrishnan, S.
    PROCEEDINGS OF 2010 INTERNATIONAL CONFERENCE ON CHEMICAL ENGINEERING AND APPLICATIONS, 2010, : 291 - 296
  • [45] ENERGY ANALYSIS OF HEAT EXCHANGER IN A HEAT EXCHANGER NETWORK
    Rauch, Martina
    Galovic, Antun
    THERMAL SCIENCE, 2018, 22 (05): : 1999 - 2011
  • [46] Analysis and Testing of a Thermoelectric Heat Exchanger Configured for Cooling a Processor Module Heat Load
    Campbell, Levi
    Wright, Lloyd
    2013 TWENTY NINTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2013, : 93 - 98
  • [47] The coordination distribution analysis on the series schemes of heat exchanger system
    Guo, Jiangfeng
    Cui, Xinying
    Huai, Xiulan
    Cheng, Keyong
    Zhang, Haiyan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 129 : 37 - 46
  • [48] Investigation on Heat Exchanger Pipe Failure
    Mondi, Papa Rao
    Kumar, D. Satish
    Kaza, Marutiram
    Bafna, Anil
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2019, 19 (06) : 1720 - 1725
  • [49] Investigation on Heat Exchanger Pipe Failure
    Papa Rao Mondi
    D. Satish Kumar
    Marutiram Kaza
    Anil Bafna
    Journal of Failure Analysis and Prevention, 2019, 19 : 1720 - 1725
  • [50] Commissioning of HTS Adapter and Heat Exchanger for Testing of High-Current HTS Conductors
    Wesche, Rainer
    Bykovsky, Nikolay
    Uglietti, Davide
    Sedlak, Kamil
    Stepanov, Boris
    Bruzzone, Pierluigi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)