Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)

被引:5
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
机构
[1] Royal Commiss Jubail & Yanbu, Jubail Tech Inst, Dept Mech Skills, Jubail Ind City, Saudi Arabia
关键词
Heat exchanger; Tube inspection; Eddy current testing; Retubing; Maintenance; CORROSION; TUBE; INSPECTION; PERFORMANCE; EROSION; NDE;
D O I
10.1007/s11668-023-01746-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Shell and tube heat exchangers are widely used in the oil and gas, petrochemical and nuclear power sectors. The most important aspect of the turnaround is the routine testing and inspection of the in-service heat exchanger. Heat exchangers in use are the primary cause of tube flaws such as pitting, corrosion, erosion, fretting corrosion, crevice corrosion, stress corrosion cracking, wear, galvanic corrosion, fatigue cracking, microbiologically influenced corrosion, and so forth. For research, a seamless nickel-iron-chromium alloy-tubed SB 163 (UNS 8810) heat exchanger was taken. The total number of tubes that need to be inspected is 286 tubes with a specification of 19.05 mm OD x 2.11 mm thickness x 5000 mm length. From the different advanced NDT techniques, the eddy current testing (ECT) was chosen for inspection since it has become one of the most popular NDT methods for locating discontinuities in heat exchanger tubes. A standard calibration tube was used to calibrate the system's response and set the sensitivity. During the inspection, the ECT probe was inserted from the below side up to the other end and collected while pulling the probe from the tube. Inspection data were recorded for the length of each tube. All indications were assessed, and defects were categorized as different extents of wall thickness loss after inspection. The inspection report shows how many tubes were found defective and need to be plugged or removed (retubing). From the inspection data (the result of statistics), defects like corrosion, pitting, wall loss, wear, etc., that resulted in notable material loss were identified. Inspection data also summarized where the defects were located (like between the first baffle and the second baffle) and are helpful for further research. After analysis using ECT reports, the defective tubes were categorized according to their defect percentage and location, which helps to do retubing effectively by avoiding the 100% retubing concept.
引用
收藏
页码:1898 / 1906
页数:9
相关论文
共 50 条
  • [31] Application of Lorentz force eddy current testing and eddy current testing on moving nonmagnetic conductors
    Carlstedt, Matthias
    Porzig, Konstantin
    Uhlig, Robert P.
    Zec, Mladen
    Ziolkowski, Marek
    Brauer, Hartmut
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 519 - 526
  • [32] Three Dimensional Shape Recovery of Fatigue Crack using Eddy Current Testing Signals
    Oshima, Kenichi
    Kojima, Fumio
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XII), 2009, 32 : 329 - 334
  • [33] Failure analysis of heat exchanger tubes of four gas coolers
    Allahkaram, S. R.
    Zakersafaee, P.
    Haghgoo, S. A. M.
    ENGINEERING FAILURE ANALYSIS, 2011, 18 (03) : 1108 - 1114
  • [34] Study on numerical analysis method for magnetized eddy current testing
    Hashimoto, M
    Asai, K
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2004, 90 (11): : 897 - 901
  • [35] Optimization of coil design for eddy current testing of multi-layer structures
    Su, Zhiyi
    Ye, Chaofeng
    Tamburrino, Antonello
    Udpa, Lalita
    Udpa, Satish
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2016, 52 (1-2) : 315 - 322
  • [36] Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe
    Lee, Hyang-beom
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2006, 26 (01) : 25 - 29
  • [37] Failure analysis of an air-cooled heat exchanger in natural gas dehydration unit
    Javidi, Mehdi
    Sadeghi, Mohammad Amin
    Jafari, Raheleh
    Hoodi, Amir Ardalan
    ENGINEERING FAILURE ANALYSIS, 2020, 115
  • [38] The corrosion failure analysis of plate pipe for plate heat exchanger
    Song Wen-ming
    Yang Gui-rong
    Hao Yuan
    Zhang Yu-fu
    ADVANCED ENGINEERING MATERIALS III, PTS 1-3, 2013, 750-752 : 2252 - +
  • [39] Thickness Measurement of Composite Material using Eddy Current Testing
    Chen, Peihua
    Huang, Pingjie
    Ye, Bo
    Li, Guohou
    Zhou, Zekui
    MULTI-FUNCTIONAL MATERIALS AND STRUCTURES II, PTS 1 AND 2, 2009, 79-82 : 1995 - 1998
  • [40] Microtexture Region Segmentation Using Matching Component Analysis Applied to Eddy Current Testing Data
    Laura Homa
    Nick Lorenzo
    Matthew Cherry
    John Wertz
    Journal of Nondestructive Evaluation, 2023, 42