Development of CMOS dosimetry in proton minibeams for enhanced QA and primary standard absorbed dose calorimetry

被引:2
作者
Flynn, Samuel [1 ,2 ]
Allport, Philip [2 ]
De Marzi, Ludovic [3 ]
Green, Stuart [4 ]
Homer, Michael [1 ]
Lee, Nigel [1 ]
Ortiz, Ramon [3 ,5 ]
Patriarca, Annalisa [3 ]
Prezado, Yolanda [3 ,5 ]
Thomas, Russell [1 ,6 ]
Price, Tony [1 ,2 ]
机构
[1] Natl Phys Lab, Med Radiat Sci Grp, Hampton Rd, Teddington TW11 0LW, England
[2] Univ Birmingham, Sch Phys & Astron, Edgbaston Campus, Birmingham B15 2TT, England
[3] Univ PSL, Inst Curie, CNRS UMR3347, Inserm U1021,Signalisat Radiobiol & Canc, F-91898 Orsay, France
[4] Univ Hosp Birmingham NHS Trust, Med Phys, Mindelsohn Way, Birmingham B15 2TH, England
[5] Univ Paris Saclay, CNRS UMR3347, Inserm U1021, Signalisat Radiobiol & Canc, F-91400 Orsay, France
[6] Univ Surrey, Fac Engn & Phys Sci, Stag Hill, Guildford GU2 7XH, England
基金
欧洲研究理事会;
关键词
Dosimetry concepts and apparatus; Instrumentation for hadron therapy; MICROBEAM; RADIOTHERAPY;
D O I
10.1088/1748-0221/18/03/P03014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Performing accurate and reliable dosimetry in spatially fractionated beams remains a significant challenge due to the steep dose gradients and microscopic scale of features. This results in many conventional detectors and instrumentation being unsuitable for online dosimetry, necessitating frequent offline validation using radiochromic film.In this study, the use of a Complementary Metal-Oxide-Semiconductor (CMOS) detector for evaluation of relative real-time dosimetry of proton minibeam radiation therapy (pMBRT) was investigated. The linearity of the CMOS detector was investigated by varying the proton beam current, with a comparison to a PTW 34001 Roos ionisation chamber used to carry out an independent check. It was found that the relative peaks and valleys of the pMBRT beam could be measured, with results comparable to EBT3XD film. The high sensitivity of the CMOS detector meant it was able to measure dose profiles from peak to valley regions, something not possible with the EBT3XD. The CMOS detector was compared to the treatment delivery log files, with correlation in beam positionseen as the beam is scanned along each slit, but not across; and agreement in beam intensity, with the CMOS detector able to observe beam interruptions.Lastly, the CMOS detector was used in conjunction with the NPL primary-standard proton calorimeter (NPL PSPC) for a preliminary study on combining the NPL PSPC with high resolution temporal information about the incident pMBRT beam. The ultimate aim of this approach is to facilitate detailed thermal modelling to reduce the overall uncertainty in the absolute dose measured from the calorimeter. In these experiments, saturation in the CMOS pixels prevented further thermal modelling of the radiation induced heat flow, however the instantaneous dose rate was observed to be comparable with the predicted NPL PSPC response obtained by masking the CMOS detector.
引用
收藏
页数:24
相关论文
共 44 条
  • [1] Displacement Damage in CMOS Image Sensors After Thermal Neutron Irradiation
    Alcalde Bessia, Fabricio
    Perez, Martin
    Sofo Haro, Miguel
    Sidelnik, Ivan
    Jeronimo Blostein, J.
    Suarez, Sergio
    Perez, Pablo
    Gomez Berisso, Mariano
    Lipovetzky, Jose
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (11) : 2793 - 2801
  • [2] How can we ensure visibility and diversity in research contributions? How the Contributor Role Taxonomy (CRediT) is helping the shift from authorship to contributorship
    Allen, Liz
    O'Connell, Alison
    Kiermer, Veronique
    [J]. LEARNED PUBLISHING, 2019, 32 (01) : 71 - 74
  • [3] Evaluating the peak-to-valley dose ratio of synchrotron microbeams using PRESAGE fluorescence
    Annabell, N.
    Yagi, N.
    Umetani, K.
    Wong, C.
    Geso, M.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 332 - 339
  • [4] [Anonymous], COMSOL
  • [5] [Anonymous], 2023, INT J RADIAT ONCOL, V115, P426
  • [6] [Anonymous], PYMEDPHYS
  • [7] [Anonymous], 1972, U.S. Patent, Patent No. [US3665762A, 3665762]
  • [8] High spatial resolution scintillator dosimetry of synchrotron microbeams
    Archer, James
    Li, Enbang
    Davis, Jeremy
    Cameron, Matthew
    Rosenfeld, Anatoly
    Lerch, Michael
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [9] Ashland, GAFCHROMICTM DOS MED
  • [10] Imaging and dosimetry of synchrotron microbeam with aluminum oxide fluorescent detectors
    Bartz, J. A.
    Sykora, G. J.
    Braeuer-Krisch, E.
    Akselrod, M. S.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1936 - 1939