Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy)

被引:5
作者
Placidi, Elisa [1 ]
Fionda, Bruno [2 ]
Rosa, Enrico [3 ]
Lancellotta, Valentina [2 ]
Napolitano, Antonio [4 ]
De Angeli, Martina [2 ]
Pastore, Francesco [2 ]
Gambacorta, Maria Antonietta [2 ,5 ]
Indovina, Luca [1 ]
Tagliaferri, Luca [2 ]
De Spirito, Marco [1 ,3 ]
机构
[1] IRCCS, Fdn Policlin Univ Agostino Gemelli, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Fis Sci Vita, Rome, Italy
[2] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Radioterapia Oncol, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Fis, Largo Francesco Vito 1, I-00168 Rome, Italy
[4] IRCCS Bambino Gesu Childrens Hosp, Dept Med Phys, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Ist Radiol, Rome, Italy
关键词
brachytherapy; TG-43; interventional radiotherapy; TG-186; non-melanoma skin cancer; NASAL VESTIBULE; RECOMMENDATIONS; TG-43;
D O I
10.5114/jcb.2023.134173
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Brachytherapy (BT, interventional radiotherapy) is a well-established radiotherapy technique capable of delivering high doses to tumors while sparing organs at risk (OARs). Currently, the clinically accepted dose calculation algorithm used is TG-43. In the TG-186 report, new model-based dose calculation algorithms (MBDCA), such as Elekta's advanced collapsed cone engine (ACE), have been introduced, although their clinical application is yet to be fully realized. This study aimed to investigate two aspects of TG-186: firstly, a comparison of dose distributions calculated with TG-43 and TG-186 for skin tumors; and secondly, an exploration of the impact of using a water bolus on the coverage of clinical target volume (CTV) and OARs. Material and methods: Ten treatment plans for high-dose-rate IRT were developed. All plans were initially calculated using the TG-43 algorithm, and were subsequently re-calculated with TG-186. In addition, one of the treatment plans was assessed with both TG-43 and TG-186, using 10 different water bolus thicknesses ranging from 0 to 5 cm. To assess dose variations, the following dose-volume histogram (DVH) parameters were compared: D2cc and D0.01cc Results and conclusions: The average dosimetric results for CTV and OARs, as calculated by both algorithms, revealed statistically significant lower values for TG-186 when compared with TG-43. The presence of a bolus was observed to enhance CTV coverage for the TG-186 algorithm, with a bolus thickness of 2 cm being the point at which ACE calculations matched those of TG-43. This study identified significant differences in dosimetric parameters for skin tumors when comparing the TG-43 and TG-186 algorithms. Moreover, it was demonstrated that the inclusion of a water bolus increased CTV coverage in TG-186 calculations.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
[31]   Biological Planning of Radiation Dose Based on In Vivo Dosimetry for Postoperative Vaginal-Cuff HDR Interventional Radiotherapy (Brachytherapy) [J].
Soror, Tamer ;
Chafii, Ramin ;
Lancellotta, Valentina ;
Tagliaferri, Luca ;
Kovacs, Gyorgy .
BIOMEDICINES, 2021, 9 (11)
[32]   A Monte Carlo dose calculation system for ophthalmic brachytherapy based on a realistic eye model [J].
Miras del Rio, Hector ;
Ortiz Lora, Antonio ;
Bertolet Reina, Alejandro ;
Terron Leon, Jose Antonio .
MEDICAL PHYSICS, 2021, 48 (08) :4542-4559
[33]   Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer [J].
Kang, Hyejoo ;
Padilla, Laura ;
Hasan, Yasmin ;
Ai-Hallaq, Hania .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (04) :354-358
[34]   Advanced non-melanoma skin cancer in elderly patients: When surgery says NO, interventional radiotherapy (brachytherapy) says YES [J].
Chichel, Adam ;
Chyrek, Artur J. ;
Kluska, Adam ;
Burchardt, Wojciech M. .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (04) :235-244
[35]   Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer [J].
Jayarathna, Sandun ;
Hoang, Matthew ;
Badkul, Rajeev ;
Hoover, Andrew .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (05) :334-343
[36]   Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer [J].
Zhang, Hualin ;
Gopalakrishnan, Mahesh ;
Lee, Plato ;
Kang, Zhuang ;
Sathiaseelan, Vythialingam .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05) :262-272
[37]   Non-melanoma Skin Cancer Treated by Contact High-dose-rate Radiotherapy (Brachytherapy) : A Mono-institutional Series and Literature Review [J].
Tagliaferri, Luca ;
Ciardo, Francesco Giuseppe ;
Fionda, Bruno ;
Casa, Calogero ;
Di Stefani, Alessandro ;
Lancellotta, Valentina ;
Placidi, Elisa ;
Macchia, Gabriella ;
Capocchiano, Nikola Dino ;
Morganti, Alessio Giuseppe ;
Kovacs, Gyorgy ;
Bussu, Francesco ;
Peris, Ketty ;
Valentini, Vincenzo .
IN VIVO, 2021, 35 (04) :2313-2319
[38]   Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom [J].
Lesperance, Marielle ;
Inglis-Whalen, M. ;
Thomson, R. M. .
MEDICAL PHYSICS, 2014, 41 (02)
[39]   Can we reduce dose to ureters as avoidance organs for MRI based brachytherapy for cervical cancer? A dosimetric feasibility study [J].
Koerner, Sean A. ;
Baig, Tanvir ;
Kim, Hayeon ;
Rodriguez-Lopez, Joshua ;
Keller, Andrew ;
Beriwal, Sushil .
BRACHYTHERAPY, 2022, 21 (02) :202-207
[40]   Clinical outcomes of low-dose-rate brachytherapy based radiotherapy for intermediate risk prostate cancer [J].
Okamoto, Keisei ;
Okuyama, Kahori ;
Kohno, Naoaki ;
Tsugawa, Takuya .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (01) :6-11