Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy)

被引:5
作者
Placidi, Elisa [1 ]
Fionda, Bruno [2 ]
Rosa, Enrico [3 ]
Lancellotta, Valentina [2 ]
Napolitano, Antonio [4 ]
De Angeli, Martina [2 ]
Pastore, Francesco [2 ]
Gambacorta, Maria Antonietta [2 ,5 ]
Indovina, Luca [1 ]
Tagliaferri, Luca [2 ]
De Spirito, Marco [1 ,3 ]
机构
[1] IRCCS, Fdn Policlin Univ Agostino Gemelli, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Fis Sci Vita, Rome, Italy
[2] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Radioterapia Oncol, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Fis, Largo Francesco Vito 1, I-00168 Rome, Italy
[4] IRCCS Bambino Gesu Childrens Hosp, Dept Med Phys, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Ist Radiol, Rome, Italy
关键词
brachytherapy; TG-43; interventional radiotherapy; TG-186; non-melanoma skin cancer; NASAL VESTIBULE; RECOMMENDATIONS; TG-43;
D O I
10.5114/jcb.2023.134173
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Brachytherapy (BT, interventional radiotherapy) is a well-established radiotherapy technique capable of delivering high doses to tumors while sparing organs at risk (OARs). Currently, the clinically accepted dose calculation algorithm used is TG-43. In the TG-186 report, new model-based dose calculation algorithms (MBDCA), such as Elekta's advanced collapsed cone engine (ACE), have been introduced, although their clinical application is yet to be fully realized. This study aimed to investigate two aspects of TG-186: firstly, a comparison of dose distributions calculated with TG-43 and TG-186 for skin tumors; and secondly, an exploration of the impact of using a water bolus on the coverage of clinical target volume (CTV) and OARs. Material and methods: Ten treatment plans for high-dose-rate IRT were developed. All plans were initially calculated using the TG-43 algorithm, and were subsequently re-calculated with TG-186. In addition, one of the treatment plans was assessed with both TG-43 and TG-186, using 10 different water bolus thicknesses ranging from 0 to 5 cm. To assess dose variations, the following dose-volume histogram (DVH) parameters were compared: D2cc and D0.01cc Results and conclusions: The average dosimetric results for CTV and OARs, as calculated by both algorithms, revealed statistically significant lower values for TG-186 when compared with TG-43. The presence of a bolus was observed to enhance CTV coverage for the TG-186 algorithm, with a bolus thickness of 2 cm being the point at which ACE calculations matched those of TG-43. This study identified significant differences in dosimetric parameters for skin tumors when comparing the TG-43 and TG-186 algorithms. Moreover, it was demonstrated that the inclusion of a water bolus increased CTV coverage in TG-186 calculations.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [21] Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms
    Rivard, Mark J.
    Beaulieu, Luc
    Mourtada, Firas
    MEDICAL PHYSICS, 2010, 37 (06) : 2645 - 2658
  • [22] Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations
    Fletcher, Elizabeth M.
    Ballester, Facundo
    Beaulieu, Luc
    Morrison, Hali
    Poher, Audran
    Rivard, Mark J.
    Sloboda, Ron S.
    Vijande, Javier
    Thomson, Rowan M.
    MEDICAL PHYSICS, 2024, 51 (01) : 694 - 706
  • [23] Effect of a lead block on alveolar bone protection in image-guided high-dose-rate interstitial brachytherapy for tongue cancer: using model-based dose calculation algorithms to correct for inhomogeneity
    Akiyama, Hironori
    Yoshida, Ken
    Takenaka, Tadashi
    Kotsuma, Tadayuki
    Masui, Koji
    Monzen, Hajime
    Sumida, Iori
    Tsujimoto, Yutaka
    Miyao, Mamoru
    Okumura, Hiroki
    Shimbo, Taiju
    Takegawa, Hideki
    Murakami, Naoya
    Inaba, Koji
    Kashihara, Tairo
    Takacsi-Nagy, Zoltan
    Tselis, Nikolaos
    Yamazaki, Hideya
    Tanaka, Eiichi
    Nihei, Keiji
    Ariji, Yoshiko
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2022, 14 (01) : 87 - 95
  • [24] Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
    Hofbauer, Julia
    Kirisits, Christian
    Resch, Alexandra
    Xu, Yingjie
    Sturdza, Alina
    Potter, Richard
    Nesvacil, Nicole
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (02) : 143 - 149
  • [25] Advanced dose calculation algorithm in superficial brachytherapy - the impact of tissue inhomogeneity on treatment plan dosimetry
    Szlag, Marta
    Kellas-Sleczko, Sylwia
    Wojcieszek, Piotr
    Stankiewicz, Magdalena
    Cholewka, Agnieszka
    Pruefer, Agnieszka
    Krzysztofiak, Tomasz
    Lelek, Piotr
    Stapor-Fudzinska, Malgorzata
    Slosarek, Krzysztof
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (04) : 1 - 6
  • [26] Dosimetric comparison of MRI-based HDR brachytherapy and stereotactic radiotherapy in patients with advanced cervical cancer: A virtual brachytherapy study
    Otahal, Bretislav
    Dolezel, Martin
    Cvek, Jakub
    Simetka, Ondrej
    Klat, Jaroslav
    Knybel, Lukas
    Molenda, Lukas
    Skacelikova, Eva
    Hlavka, Ales
    Feltl, David
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (06) : 399 - 404
  • [27] A MC-based anthropomorphic test case for commissioning model-based dose calculation in interstitial breast 192-Ir HDR brachytherapy
    Peppa, Vasiliki
    Thomson, Rowan M.
    Enger, Shirin A.
    Fonseca, Gabriel P.
    Lee, Choonik
    Lucero, Joseph N. E.
    Mourtada, Firas
    Siebert, Frank-Andre
    Vijande, Javier
    Papagiannis, Panagiotis
    MEDICAL PHYSICS, 2023, 50 (07) : 4675 - 4687
  • [28] A brief look at model-based dose calculation principles, practicalities, and promise
    Slobodo, Ron S.
    Morrison, Hali
    Cowston-Grant, Brie
    Menon, Geetha V.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (01) : 79 - 88
  • [29] Individualized mould-based high-dose-rate brachytherapy for perinasal skin tumors: technique evaluation from a dosimetric point of view
    Scherf, Christian
    Licher, Joerg
    Mletzko, Christina
    Trommel, Martin
    Tselis, Nikolaos
    Chatzikonstantinou, Georgios
    Diefenhardt, Markus
    Roedel, Claus
    Koehn, Janett
    Ramm, Ulla
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (02) : 179 - 187
  • [30] A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192Ir brachytherapy
    Ma, Yunzhi
    Vijande, Javier
    Ballester, Facundo
    Tedgren, Asa Carlsson
    Granero, Domingo
    Haworth, Annette
    Mourtada, Firas
    Fonseca, Gabriel Paiva
    Zourari, Kyveli
    Papagiannis, Panagiotis
    Rivard, Mark J.
    Siebert, Frank-Andre
    Sloboda, Ron S.
    Smith, Ryan
    Chamberland, Marc J. P.
    Thomson, Rowan M.
    Verhaegen, Frank
    Beaulieu, Luc
    MEDICAL PHYSICS, 2017, 44 (11) : 5961 - 5976