Clinical application of artificial intelligence-assisted three-dimensional planning in direct anterior approach hip arthroplasty

被引:5
|
作者
Yang, Weihua [1 ]
Gao, Tianyi [2 ]
Liu, Xingyu [2 ]
Shen, Kaiwei [1 ]
Lin, Feitai [1 ]
Weng, Yan [1 ]
Lin, Bei [1 ]
Liang, Deng [1 ]
Feng, Eryou [3 ]
Zhang, Yiling [2 ]
机构
[1] Fuzhou Second Hosp, Dept Arthrosis Surg, Fuzhou, Peoples R China
[2] Longwood Valley MedTech, 2 Ronghua South Rd, Beijing, Peoples R China
[3] Fujian Med Univ, Union Hosp, Dept Ultrasound, 29 Xinquan Rd, Fuzhou 350001, Peoples R China
关键词
Total hip arthroplasty; 3D preoperative planning; Artificial intelligence; LEG LENGTH DISCREPANCY; ABDUCTOR MUSCLE STRENGTH; COMPLICATION RATE; RISK-FACTOR; FLUOROSCOPY; POSTERIOR; RELIABILITY; FAILURE;
D O I
10.1007/s00264-023-06029-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The objective of this study was to investigate the efficacy of an artificial intelligence-assisted 3D planning system (AIHIP) in total hip arthroplasty by direct anterior approach and assess the reliability of the AIHIP preoperative program in terms of both interobserver and intraobserver agreement.Methods A retrospective analysis was conducted on patients who underwent unilateral primary THA via direct anterior approach from June 2019 to March 2022. Participants were randomly assigned to receive either the AIHIP system (n = 220) or the 2D template (control group) (n = 220) for preoperative planning. The primary outcome aimed to evaluate the correspondence between the prosthesis selected intro-operation and the one planned preoperatively, as well as to calculate the intraclass correlation coefficient (ICC). Secondary outcomes included operation time, intraoperative blood loss, fluoroscopy times, Harris hip score (HHS), lower limb length difference (LLD), femoral offset (FO), and bilateral femoral offset difference.Results No significant differences were observed in gender, age, body mass index (BMI), aetiology, and American Society of Anesthesiologists (ASA) score between the two groups. Both planning methods exhibited good intraobserver agreement for component planning (ICC: 0.941-0.976). Interobserver agreement for component planning was comparable between the two methods (ICC: 0.882-0.929). In the AIHIP group, the accuracy of acetabular cup and femoral stem prosthetics planning significantly improved, with accuracies within the size range of +/- 0 and +/- 1 being 76.8% and 90.5% and 79.5% and 95.5%, respectively. All differences between two groups were statistically significant (p < 0.05). Patients receiving AIHIP preoperative planning experienced shorter operation times, reduced intraoperative blood loss, fewer fluoroscopy times, and lower leg length discrepancy (LLD) (p < 0.05). Moreover, they demonstrated a higher Harris hip score (HHS) at three days post-surgery (p < 0.05). However, no significant differences were found in femoral offset (FO), difference of bilateral femoral offsets, and HHS at 1 month after the operation.Conclusion Utilizing AIHIP for preoperative planning of direct anterior approach THA can significantly enhance the accuracy of prosthetic sizing with good reliability, decrease operation time, reduce intraoperative blood loss, and more effectively restore the length of both lower limbs. This approach has greater clinical application value.
引用
收藏
页码:773 / 783
页数:11
相关论文
共 50 条
  • [21] Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty
    Wako, Yasushi
    Nakamura, Junichi
    Miura, Michiaki
    Kawarai, Yuya
    Sugano, Masahiko
    Nawata, Kento
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 601 - 607
  • [22] Research on the Application of Artificial Intelligence Technology in the Three-dimensional Teaching Field
    Xu, Xinglun
    2022 ASIA CONFERENCE ON ADVANCED ROBOTICS, AUTOMATION, AND CONTROL ENGINEERING (ARACE 2022), 2022, : 161 - 165
  • [23] Comparison of postoperative outcomes between endoscopy assisted minimal invasive direct anterior approach and bikini direct anterior approach in total hip arthroplasty
    Deng, Zhibo
    Dai, Hanhao
    Song, Chao
    Luo, Fenqi
    Wu, Yijing
    Zhang, Rongsheng
    Luo, Jun
    Xu, Jie
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (08) : 3705 - 3713
  • [24] Comparison of direct anterior versus posterolateral approach total hip arthroplasty for developmental dysplasia of the hip: A clinical effectiveness retrospective study
    Lin, Wuyuanhao
    MEDICINE, 2025, 104 (14) : e42024
  • [25] Direct anterior approach for total hip arthroplasty: Hip biomechanics and muscle activation during three walking tasks
    Ippolito, Giorgio
    Serrao, Mariano
    Conte, Carmela
    Castiglia, Stefano Filippo
    Rucco, Ferdinando
    Bonacci, Enrico
    Miscusi, Massimo
    Pierelli, Francesco
    Bini, Fabiano
    Marinozzi, Franco
    Zitiello, Michele
    Ragona, Chiara
    De Marinis, Giancarlo
    CLINICAL BIOMECHANICS, 2021, 89
  • [26] The Direct Anterior Approach versus the Posterolateral Approach on the Outcome of Total Hip Arthroplasty: A Retrospective Clinical Study
    Wang, Zhao
    Bao, Hong-Wei
    Hou, Jing-Zhao
    Ju, Bin
    Wu, Can-Hua
    Zhou, Yao-Jiang
    Gu, Xiao-Ming
    Wang, Hai-Hong
    ORTHOPAEDIC SURGERY, 2022, 14 (10) : 2563 - 2570
  • [27] Comparisons of Preoperative Three-Dimensional Planning and Surgical Reconstruction in Primary Cementless Total Hip Arthroplasty
    Hassani, Hassen
    Cherix, Stephane
    Ek, Eugene T.
    Ruediger, Hannes A.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (06) : 1273 - 1277
  • [28] Three-dimensional pre-operative planning of primary hip arthroplasty: a systematic literature review
    Moralidou, Maria
    Di Laura, Anna
    Henckel, Johann
    Hothi, Harry
    Hart, Alister J.
    EFORT OPEN REVIEWS, 2020, 5 (12) : 845 - 855
  • [29] Intraoperative application of three-dimensional printed guides in total hip arthroplasty: A systematic review
    Crone, Tim P.
    Cornelissen, Bart M. W.
    Van Oldenrijk, Jakob
    Bos, Pieter Koen
    Veltman, Ewout S.
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (07): : 660 - 667
  • [30] Patient Radiation Exposure During Fluoro-Assisted Direct Anterior Approach Total Hip Arthroplasty
    Curtin, Brian M.
    Armstrong, Lucas C.
    Bucker, Brandon T.
    Odum, Susan M.
    Jiranek, William A.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06) : 1218 - 1221