The Comparative Analysis of Single Plating Versus Double Plating in the Treatment of Unstable Bicondylar Proximal Tibial Plateau Fractures

被引:0
作者
Raj, Manish [1 ]
Singh, Santosh Kumar [2 ]
Rajput, Ajay K. [3 ]
Gill, Simrat Pal [3 ]
Verma, Satyendra K. [4 ]
Sonarkar, Sushant S. [5 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Orthoped, Deoghar, India
[2] Maa Vindhyavasini Autonomous State Med Coll, Dept Orthoped, Mirzapur, India
[3] Uttar Pradesh Univ Med Sci UPUMS, Dept Orthopaed, Saifai, India
[4] Rajarshi Dashrath Autonomous State Med Coll RDASMC, Dept Orthoped, Ayodhya, India
[5] 7 AF Hosp, Dept Orthoped, Kanpur, India
关键词
rasmussen's criteria; dual locking plate; radiological outcome; oxford knee score; schatzker; unstable; bicondylar tibial plateau fracture; LATERAL LOCKING PLATE; OPEN REDUCTION; POSTEROMEDIAL FRAGMENT; INTERNAL-FIXATION; STABILIZATION; OUTCOMES; COMPLICATIONS;
D O I
10.7759/cureus.46840
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionIn the present study, we aimed to compare the clinical and radiological results of the single lateral locking plate fixation method to the dual plate (DP) fixation method in cases of unstable bicondylar proximal tibial plateau fractures.Materials and methodsFifty-six patients managed surgically with internal fixation for unstable bicondylar tibial plateau fractures (UBTF) (Schatzker type V and type VI or Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association {AO/OTA} type 41-C) over 36 months from January 2017 to December 2020 were included in this prospective study. All the fractures were fixed surgically either using dual locking plates through double incisions (DP group) or with a single lateral locking plate (single plate {SP} group). All intraoperative and postoperative complications were assessed and recorded. Oxford Knee Score (OKS), Rasmussen's functional grading system, and Rasmussen's radiological scoring system were used to evaluate the functional and radiological outcomes.ResultAll of the patients were followed for at least 12 months. Twenty-six patients were fixed with a single lateral locking plate, and 30 patients were fixed with a double-incision dual locking plate. The mean Oxford Knee Score (OKS) was 43.24 +/- 4.46 in the DP group and 42.7 +/- 2.57 in the SP group (P = 0.544). The mean Rasmussen's functional score (RFS) score in the present study was 26.6 +/- 2.21 in the DP group and 24.97 +/- 3.92 in the SP group (P = 0.056). At the final follow-up, the mean Rasmussen's radiological score (RRS) was 9.06 +/- 1.01 in the DP group and 8.1 +/- 0.81 in the SP group (P = 0.0003).ConclusionThere are no statistically significant differences in the functional outcomes between the two groups, but higher benefits were found in the radiological outcomes in the dual plating group as compared to single lateral locking plate group.
引用
收藏
页数:14
相关论文
共 32 条
[1]   Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns [J].
Barei, David P. ;
O'Mara, Timothy J. ;
Taitsman, Lisa A. ;
Dunbar, Robert P. ;
Nork, Sean E. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) :176-182
[2]   Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates [J].
Barei, David P. ;
Nork, Sean E. ;
Mills, William J. ;
Coles, Chad P. ;
Henley, M. Bradford ;
Benirschke, Stephen K. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1713-1721
[3]   Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique [J].
Barei, DP ;
Nork, SE ;
Mills, WJ ;
Henley, MB ;
Benirschke, SK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :649-657
[4]  
Chang HR, 2016, INT ORTHOP, V40, P2129, DOI 10.1007/s00264-016-3157-8
[5]   Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures [J].
Citak, Caner ;
Kayali, Cemil ;
Ozan, Firat ;
Altay, Taskin ;
Karahan, Huseyin Gokhan ;
Yamak, Kamil .
CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) :151-158
[6]   Tibial plateau fractures: compared outcomes between ARIF and ORIF [J].
Dall'Oca, C. ;
Maluta, T. ;
Lavini, F. ;
Bondi, M. ;
Micheloni, G. M. ;
Bartolozzi, P. .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2012, 7 (03) :163-175
[7]   Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[8]   Unstable Bicondylar Tibial Plateau Fractures: A Clinical Investigation [J].
Eggli, Stefan ;
Hartel, Maximilian J. ;
Kohl, Sandro ;
Hallpt, Uli ;
Exadakrylos, Aristomenis K. ;
Roeder, Christoph .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (10) :673-679
[9]   Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating [J].
Egol, KA ;
Su, E ;
Tejwani, NC ;
Sims, SH ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (02) :340-346
[10]   Reliability of locked plating in tibial plateau fractures with a medial component [J].
Ehlinger, M. ;
Rahme, M. ;
Moor, B. -K. ;
Di Marco, A. ;
Brinkert, D. ;
Adam, P. ;
Bonnomet, F. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (02) :173-179