Comparison of Computed Tomography-Based Artificial Intelligence Modeling and Magnetic Resonance Imaging in Diagnosis of Cholesteatoma

被引:4
|
作者
Eroglu, Orkun [1 ]
Eroglu, Yesim [2 ]
Yildirim, Muhammed [3 ]
Karlidag, Turgut [1 ]
Cinar, Ahmet [4 ]
Akyigit, Abdulvahap [1 ]
Kaygusuz, Irfan [1 ]
Yildirim, Hanefi [2 ]
Keles, Erol [1 ]
Yalcin, Sinasi [1 ]
机构
[1] Firat Univ, Sch Med, Dept Otorhinolaryngol, Elazig, Turkiye
[2] Firat Univ, Sch Med, Dept Radiol, Elazig, Turkiye
[3] Malatya Turgut Ozal Univ, Fac Engn & Nat Sci, Dept Comp Engn, Malatya, Turkiye
[4] Firat Univ, Sch Engn, Dept Comp Engn, Elazig, Turkiye
关键词
Chronic otitis media; cholesteatoma; artificial intelligence; deep learning; CT; MRI; MIDDLE-EAR; CANAL WALL; MRI;
D O I
10.5152/iao.2023.221004
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
BACKGROUND: In this study, we aimed to compare the success rates of computed tomography image-based artificial intelligence models and magnetic resonance imaging in the diagnosis of preoperative cholesteatoma. METHODS: The files of 75 patients who underwent tympanomastoid surgery with the diagnosis of chronic otitis media between January 2010 and January 2021 in our clinic were reviewed retrospectively. The patients were classified into the chronic otitis group without cholesteatoma (n = 34) and the chronic otitis group with cholesteatoma (n = 41) according to the presence of cholesteatoma at surgery. A dataset was created from the preoperative computed tomography images of the patients. In this dataset, the success rates of artificial intelligence in the diagnosis of cholesteatoma were determined by using the most frequently used artificial intelligence models in the literature. In addition, preoperative MRI were evaluated and the success rates were compared. RESULTS: Among the artificial intelligence architectures used in the paper, the lowest result was obtained in MobileNetV2 with an accuracy of 83.30%, while the highest result was obtained in DenseNet201 with an accuracy of 90.99%. In our paper, the specificity of preoperative magnetic resonance imaging in the diagnosis of cholesteatoma was 88.23% and the sensitivity was 87.80%. CONCLUSION: In this study, we showed that artificial intelligence can be used with similar reliability to magnetic resonance imaging in the diagnosis of cholesteatoma. This is the first study that, to our knowledge, compares magnetic resonance imaging with artificial intelligence models for the purpose of identifying preoperative cholesteatomas.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 50 条
  • [41] Comparison of Hip Reduction Using Magnetic Resonance Imaging or Computed Tomography in Hip Dysplasia
    Chin, Matthew Steven
    Betz, Brad W.
    Halanski, Matthew Aaron
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2011, 31 (05) : 525 - 529
  • [42] Prospective comparison of magnetic resonance imaging and computed tomography in diagnosing occult scaphoid fractures
    Sahu, Ajay
    Kuek, Dorothy K. C.
    MacCormick, Andrew
    Gozzard, Charles
    Ninan, Tishi
    Fullilove, Sue
    Suresh, Priya
    ACTA RADIOLOGICA, 2023, 64 (01) : 201 - 207
  • [43] Hyperpolarized Magnetic Resonance and Artificial Intelligence: Frontiers of Imaging in Pancreatic Cancer
    Enriquez, Jose S.
    Chu, Yan
    Pudakalakatti, Shivanand
    Hsieh, Kang Lin
    Salmon, Duncan
    Dutta, Prasanta
    Millward, Niki Zacharias
    Lurie, Eugene
    Millward, Steven
    McAllister, Florencia
    Maitra, Anirban
    Sen, Subrata
    Killary, Ann
    Zhang, Jian
    Jiang, Xiaoqian
    Bhattacharya, Pratip K.
    Shams, Shayan
    JMIR MEDICAL INFORMATICS, 2021, 9 (06)
  • [44] Comparison of computed tomography and magnetic resonance imaging in cervical cancer brachytherapy: A systematic review
    Wang, Fang
    Tang, Qiuying
    Lv, Guoxiao
    Zhao, Feng
    Jiang, Xue
    Zhu, Xinli
    Li, Xinke
    Yan, Senxiang
    BRACHYTHERAPY, 2017, 16 (02) : 353 - 365
  • [45] The role of artificial intelligence in cardiovascular magnetic resonance imaging
    Aromiwura, Afolasayo A.
    Cavalcante, Joao L.
    Kwong, Raymond Y.
    Ghazipour, Aryan
    Amini, Amir
    Bax, Jeroen
    Raman, Subha
    Pontone, Gianluca
    Kalra, Dinesh K.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2024, 86 : 13 - 25
  • [46] Artificial intelligence in the diagnosis of shoulder injuries through magnetic resonance imaging: a scoping review
    Ramirez-Perez, Laura
    Cuesta-Vargas, Antonio Ignacio
    EVOLUTIONARY INTELLIGENCE, 2025, 18 (02)
  • [47] The role of diffusion-weighted magnetic resonance imaging in the diagnosis of cholesteatoma
    Tosun, Alptekin
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2008, 28 (03): : 265 - 268
  • [48] Applications of artificial intelligence in computed tomography imaging for phenotyping pulmonary hypertension
    Sharkey, Michael J.
    Checkley, Elliot W.
    Swift, Andrew J.
    CURRENT OPINION IN PULMONARY MEDICINE, 2024, 30 (05) : 464 - 472
  • [49] 3.0T magnetic resonance imaging-based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography-based models
    Newhouse, Alexander C.
    Alter, Thomas D.
    Handoklow, Lyla A.
    Espinoza Orias, Alejandro A.
    Inoue, Nozomu
    Nho, Shane J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (09) : 2017 - 2025
  • [50] Comparison of computed tomography- and magnetic resonance imaging-based target delineation for cervical cancer brachytherapy
    Wang, Fang
    Bu, Luyi
    Wu, Qun
    Jiang, Xue
    Wu, Lingyun
    Li, Yu
    Xi, Bin
    Lu, Zhongjie
    Yan, Senxiang
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (04) : 367 - 374