Honeybee stinger-based biopsy needle and influence of the barbs on needle forces during insertion/extraction into the iliac crest: A multilayer finite element approach

被引:6
作者
Nadda, Rahul [1 ]
Repaka, Ramjee [1 ,2 ]
Sahani, Ashish Kumar [1 ]
机构
[1] Indian Inst Technol, Dept Biomed Engn, Ropar 140001, Punjab, India
[2] Indian Inst Technol, Dept Mech Engn, Ropar 140001, Punjab, India
关键词
Insertion force; Extraction force; Tissue deformation; Bioinspired; Needle deflection; Multilayer model; Finite element method; TISSUE INTERACTION FORCES; MICROSTRUCTURED BARBS; INSERTION METHODS; DEFLECTION; PENETRATION; SIMULATION; BEHAVIOR;
D O I
10.1016/j.compbiomed.2023.107125
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Bone marrow biopsy (BMB) needles are frequently used in medical procedures, including extracting biological tissue to identify specific lesions or abnormalities discovered during a medical examination or a radiological scan. The forces applied by the needle during the cutting operation significantly impact the sample quality. Excessive needle insertion force and possible deflection might cause tissue damage, compromising the integrity of the biopsy specimen. The present study aims at proposing a revolutionary bioinspired needle design that will be utilized during the BMB procedure. A non-linear finite element method (FEM) has been used to analyze the insertion/extraction mechanisms of the honeybee-inspired biopsy needle with barbs into/from the human skin -bone domain (i.e., iliac crest model). It can be seen from the results of the FEM analysis that stresses are concentrated around the bioinspired biopsy needle tip and barbs during the needle insertion process. Also, these needles reduce the insertion force and reduce the tip deflection. The insertion force in the current study has been reduced by 8.6% for bone tissue and 22.66% for skin tissue layers. Similarly, the extraction force has been reduced by an average of 57.54%. Additionally, it has been observed that the needle-tip deflection got reduced from 10.44 mm for a plain bevel needle to 6.3 mm for a barbed biopsy bevel needle. According to the research findings, the proposed bioinspired barbed biopsy needle design could be utilized to create and produce novel biopsy needles for successful and minimally invasive piercing operations.
引用
收藏
页数:18
相关论文
共 44 条
  • [31] Mechanics of a mosquito bite with applications to microneedle design
    Ramasubramanian, M. K.
    Barham, O. M.
    Swaminathan, V.
    [J]. BIOINSPIRATION & BIOMIMETICS, 2008, 3 (04)
  • [32] Insertion mechanics of bioinspired needles into soft tissues
    Sahlabadi, Mohammad
    Khodaei, Seyedvahid
    Jezler, Kyle
    Hutapea, Parsaoran
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2018, 27 (05) : 284 - 291
  • [33] Novel design of honeybee-inspired needles for percutaneous procedure
    Sahlabadi, Mohammad
    Hutapea, Parsaoran
    [J]. BIOINSPIRATION & BIOMIMETICS, 2018, 13 (03)
  • [34] Design and evaluation of a wasp-inspired steerable needle
    Scali, M.
    Kreeft, D.
    Breedveld, P.
    Dodou, D.
    [J]. BIOINSPIRATION, BIOMIMETICS, AND BIOREPLICATION 2017, 2017, 10162
  • [35] Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin
    Shergold, OA
    Fleck, NA
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (05): : 838 - 848
  • [36] A Mosquito Inspired Strategy to Implant Microprobes into the Brain
    Shoffstall, Andrew J.
    Srinivasan, Suraj
    Willis, Mitchell
    Stiller, Allison M.
    Ecker, Melanie
    Voit, Walter E.
    Pancrazio, Joseph J.
    Capadona, Jeffrey R.
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [37] Stellman J.T., 2009, THESIS GEORGIA I TEC
  • [38] Needle-tissue interaction forces - A survey of experimental data
    van Gerwen, Dennis J.
    Dankelman, Jenny
    van den Dobbelsteen, John J.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2012, 34 (06) : 665 - 680
  • [39] Homogenized stiffness matrices for mineralized collagen fibrils and lamellar bone using unit cell finite element models
    Vercher, Ana
    Giner, Eugenio
    Arango, Camila
    Tarancon, Jose E.
    Javier Fuenmayor, F.
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2014, 13 (02) : 437 - 449
  • [40] STRATUM CORNEUM BIOMECHANICAL PROPERTIES .1. INFLUENCE OF RELATIVE HUMIDITY ON NORMAL AND EXTRACTED HUMAN STRATUM CORNEUM
    WILDNAUER, RH
    BOTHWELL, JW
    DOUGLASS, AB
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1971, 56 (01) : 72 - +