Effects of palm cooling on thermoregulatory-related and subjective indicators during exercise in a hot environment

被引:1
|
作者
Iwata, Risa [1 ,2 ]
Kawamura, Takuji [2 ]
Okabe, Fumitake [3 ]
Fujita, Zenya [3 ]
机构
[1] Japan Inst Sports Sci, Dept Sports Sci, 3-15-1 Nishigaoka, Tokyo 1150056, Japan
[2] Waseda Inst Sport Sci, 2-579-15 Mikajima, Tokorozawa, Saitama 3591192, Japan
[3] Waseda Univ, Fac Sport Sci, 2-579-15 Mikajima, Tokorozawa, Saitama 3591192, Japan
关键词
Palm cooling; Core body temperature; Exercise in a hot environment; Sweating functions; CORE TEMPERATURE; HEAT; RESPONSES; PERFORMANCE; HAND; INGESTION; ENDURANCE; CAPACITY;
D O I
10.1016/j.jtherbio.2024.103803
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Palm cooling is a simple and easily implemented intervention strategy during exercise. We aimed to examine the effects of bilateral palm cooling before and during exercise on thermoregulatory-related and subjective indicators in a hot environment. Ten active men (age: 21 +/- 1 years; height 172.2 +/- 5.7 cm; weight 67.4 +/- 7.2 kg) underwent three experimental trials at the same time of the day, consisting of palm cooling with 12(degrees)C (ICE12(degrees)C), palm cooling with 0(degrees)C (ICE0(degrees)C) where vasoconstriction is supposed to occur, and control (CON) trials. After 30 min rest at ambient temperature, participants performed 20 min exercise at 33C, 60% relative humidity. Rectal temperature, skin temperature, rate of perceived exertion, heart rate, local sweat rate, oxygen uptake, carbon dioxide production, and respiratory exchange ratio did not differ between the trials. Thermal sensation and comfort were lower in the ICE12(degrees)C and ICE0(degrees)C trials than in the CON trial, but the ICE0(degrees)C trial showed a longer duration of cold sensation than the ICE12(degrees)C trial. Palm cooling at 12(degrees)C and 0C improved thermal sensation and thermal comfort during exercise in a hot environment, although there was no effect on core body temperature, sweating, and cardiorespiratory function. Bilateral palm cooling at 12(degrees)C and 0C improve subjective indicators during exercise in a hot environment and these effects are slightly greater at 0C than at 12(degrees)C cooling, while having no effect on thermoregulatory-related indicators. These results suggest that bilateral palm cooling at lower temperatures may safely reduce the perception of warmth during exercise in a hot environment.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Effects of sportswear on thermoregulatory responses during exercise in a hot environment
    Hiromi, SY
    Nakai, S
    Yoshida, T
    Takahashi, E
    ENVIRONMENTAL ERGONOMICS: THE ERGONOMICS OF HUMAN COMFORT, HEALTH AND PERFORMANCE IN THE THERMAL ENVIRONMENT, 2005, 3 : 65 - 70
  • [2] Palm cooling does not reduce heat strain during exercise in a hot, dry environment
    Amorim, Fabiano T.
    Yamada, Paulette M.
    Robergs, Robert A.
    Schneider, Suzanne M.
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2010, 35 (04) : 480 - 489
  • [3] Thermoregulatory responses of lower limb amputees during exercise in a hot environment
    Hasegawa, Hiroshi
    Makino, Hitoshi
    Fukuhara, Koki
    Mikami, Yukio
    Kimura, Hiroaki
    Adachi, Nobuo
    JOURNAL OF THERMAL BIOLOGY, 2020, 91
  • [4] Differences between sexes in thermoregulatory responses and exercise time during endurance exercise in a hot environment following pre-cooling with ice slurry ingestion
    Iwata, Risa
    Kawamura, Takuji
    Hosokawa, Yuri
    Chang, Lili
    Suzuki, Katsuhiko
    Muraoka, Isao
    JOURNAL OF THERMAL BIOLOGY, 2020, 94
  • [5] Effects of Cooling During Exercise on Thermoregulatory Responses of Men With Paraplegia
    Bongers, Coen C. W. G.
    Eijsvogels, Thijs M. H.
    van Nes, Ilse J. W.
    Hopman, Maria T. E.
    Thijssen, Dick H. J.
    PHYSICAL THERAPY, 2016, 96 (05): : 650 - 658
  • [6] Thermoregulatory, Cardiovascular, and Perceptual Responses to Intermittent Cooling During Exercise in a Hot, Humid Outdoor Environment
    Cleary, Michelle A.
    Toy, Michelle G.
    Lopez, Rebecca M.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (03) : 792 - 806
  • [7] Intermittent face cooling reduces perceived exertion during exercise in a hot environment
    Miyazawa, Taiki
    Mizutani, Mirai
    Sheahan, John Patrick
    Ichikawa, Daisuke
    JOURNAL OF PHYSIOLOGICAL ANTHROPOLOGY, 2021, 40 (01)
  • [8] Effects of fencing uniform on thermoregulatory responses during exercise in hot environment: Practical field study and laboratory experiment
    Shin-Ya, H
    Yoshida, T
    Takahashi, E
    Tsuneoka, H
    Nakai, S
    JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2003, 52 (01) : 75 - 88
  • [9] Rates of fluid ingestion alter pacing but not thermoregulatory responses during prolonged exercise in hot and humid conditions with appropriate convective cooling
    J. P. Dugas
    U. Oosthuizen
    R. Tucker
    T. D. Noakes
    European Journal of Applied Physiology, 2009, 105
  • [10] Rates of fluid ingestion alter pacing but not thermoregulatory responses during prolonged exercise in hot and humid conditions with appropriate convective cooling
    Dugas, J. P.
    Oosthuizen, U.
    Tucker, R.
    Noakes, T. D.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 105 (01) : 69 - 80