Effect of switching from continuous to bilevel positive airway pressure on sleep quality in patients with obstructive sleep apnea: the prospective POP IN VAuto study

被引:2
|
作者
Palot, Alain [1 ]
Nguyen, Xuan-Lan [2 ]
Launois, Sandrine [2 ]
Prigent, Arnaud [3 ]
Graml, Andrea [4 ]
Aversenq, Elodie [5 ]
Koltes, Christian [6 ]
Recart, Didier [7 ]
Lavergne, Florent [5 ]
机构
[1] Hop St Joseph, Marseille, France
[2] Ctr Sommeil CEREVES, Paris, France
[3] Polyclin St Laurent, Rennes, France
[4] ResMed Sci Ctr, Munich, Germany
[5] ResMed Sci Ctr, St Priest, France
[6] Ctr Sommeil, Metz, France
[7] Clin Aguilera, Biarritz, France
关键词
Positive airway pressure (PAP); obstructive sleep apnea (OSA); sleep quality; patient reported outcomes; daytime sleepiness; patient preference; OF-LIFE; AMERICAN ACADEMY; ASSOCIATION; METAANALYSIS; SYMPTOMS; CPAP; ACUPUNCTURE; EFFICACY; MOOD;
D O I
10.21037/jtd-22-825
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Issues with tolerability and side effects can decrease continuous positive airway pressure (CPAP) device usage and the benefits of therapy. Different positive airway pressure (PAP) therapy modes providing expiratory pressure relief or using a different pressure during inspiration vs. expiration (bilevel PAP) may alleviate some of these issues. This multicenter, prospective study evaluated the effects of switching from CPAP to bilevel PAP (VAuto mode) on respiratory parameters, device usage, side effects and patient-reported outcomes in patients with obstructive sleep apnea (OSA). Methods: Eligible OSA patients had started CPAP >= 3 months previously, had good compliance (mean 6.1 +/- 2.0 h/night) and well-controlled OSA [residual apnea-hypopnea index (AHI) 4.9 +/- 3.1/h] but had pressure tolerance issues or persistent side effects/discomfort. All were switched from CPAP to bilevel PAP (AirCurve 10 VAuto; ResMed). Effectiveness (residual AHI), sleep quality, daytime sleepiness, fatigue, therapy-related side effects, and patient satisfaction/preference were assessed after 3 months and 1 year. Results: Forty patients were analyzed (68% male, age 64 +/- 11 years, body mass index 30.7 +/- 5.8 kg/m2). At 3 months and 1 year after switching to bilevel PAP, median [interquartile range] residual AHI was 4/h [2-5.3] and 3.7/h [1.8-5], respectively, and device usage was 7.0 [4.9-7.5] and 6.4 [4.4-7.3] h/night, respectively. Device switch was associated with significant reductions from baseline in expiratory PAP {from 12 [11-13] to 8 [7-9] cmH2O at 3 months (P<0.001) and 9 [8-12] cmH2O at 1 year (P=0.005)}, 95th percentile pressure {from 14 [12-14] to 10 [9-11] and 10 [8-11] cmH2O; P<0.001 and P=0.001, respectively} and leak {from 1 [0-6] to 0 [0-1] and 0 [0-2] L/min; P=0.049 and P=0.033, respectively}. The Pittsburgh Sleep Quality Index score decreased significantly from baseline to 3 and 6 months [7.2 +/- 4.0 to 5.0 +/- 3.2 (P=0.005) and 4.5 +/- 2.7 (P<0.001), respectively]. CPAP-related mouth dryness, choking sensation and aerophagia were significantly improved one year after switching to bilevel PAP. Bilevel PAP was preferred over CPAP by 90% of patients.Conclusions: Switching to bilevel PAP had several benefits in patients struggling with CPAP, facilitating therapy acceptance and ongoing device usage.
引用
收藏
页码:918 / 927
页数:10
相关论文
共 50 条
  • [1] Effect of continuous positive airway pressure vs placebo continuous positive airway pressure on sleep quality in obstructive sleep apnea
    Loredo, JS
    Ancoli-Israel, S
    Dimsdale, JE
    CHEST, 1999, 116 (06) : 1545 - 1549
  • [2] Effect of positive airway pressure compliance on laryngopharyngeal reflux in obstructive sleep apnea patients
    Tawaranurak, Krongthong
    Werathammo, Methini
    BMC RESEARCH NOTES, 2023, 16 (01)
  • [3] Benefit of continuous positive airway pressure on work quality in patients with severe obstructive sleep apnea
    Botokeky, Elsa
    Freymond, N.
    Gormand, F.
    Le Cam, P.
    Chatte, G.
    Kuntz, J.
    Liegeon, M. N.
    Gaillot-Drevon, M.
    Massardier-Pilonchery, A.
    Fiquemont, A.
    Fort, E.
    Marcu, M.
    Petitjean, T.
    Charbotel, B.
    SLEEP AND BREATHING, 2019, 23 (03) : 753 - 759
  • [4] Acute effects of continuous positive airway pressure in patients with obstructive sleep apnea
    Han, Su-Hyun
    Lee, Sang-Ahm
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2020, 54 (01) : 26 - 31
  • [5] The effect of continuous positive airway pressure therapy on atrial fibrillation in patients with obstructive sleep apnea
    Hu, Jiancheng
    Zuo, Siyuan
    Qian, Jiahui
    Cheng, Fangfang
    Wang, Dengji
    Deng, Yanyan
    Lu, Dasheng
    FRONTIERS IN MEDICINE, 2025, 12
  • [6] The effect of continuous positive airway pressure on dyslipidemia in patients with obstructive sleep apnea
    Shehab-Eldin, Walid Abdelmohsen
    Elhabashy, Mahmoud
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2019, 13 (01) : 120 - 124
  • [7] Management of Obstructive Sleep Apnea by Continuous Positive Airway Pressure
    Weaver, Terri E.
    Sawyer, Amy
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2009, 21 (04) : 403 - +
  • [8] Evaluating the sleep quality of obstructive sleep apnea patients after continuous positive airway pressure treatment
    Hsu, Chien-Chang
    Wu, Jie-Han
    Chiu, Hou-Chang
    Lin, Chia-Mo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (07) : 870 - 878
  • [9] The effect of continuous positive airway pressure therapy on the prevalence of masked hypertension in obstructive sleep apnea patients
    Sova, Milan
    Sovova, Eliska
    Hobzova, Milada
    Zapletalova, Jana
    Kamasova, Monika
    Kolek, Vitezslav
    BIOMEDICAL PAPERS-OLOMOUC, 2015, 159 (02): : 277 - 282
  • [10] Continuous positive airway pressure in obstructive sleep apnea
    Meurice, Jean Claude
    Antone, Elise
    Gilbert, Mylene
    Watrin, Audrey
    Bironneau, Vanessa
    PRESSE MEDICALE, 2017, 46 (04): : 423 - 431