Fibula Nail versus Locking Plate Fixation-A Biomechanical Study

被引:6
|
作者
Kohler, Felix Christian [1 ]
Schenk, Philipp [2 ]
Nies, Theresa [1 ]
Hallbauer, Jakob [1 ]
Hofmann, Gunther Olaf [1 ,3 ]
Biedermann, Uta [4 ]
Kielstein, Heike [5 ]
Wildemann, Britt [1 ]
Ramm, Roland [6 ]
Ullrich, Bernhard Wilhelm [1 ,3 ]
机构
[1] Friedrich Schiller Univ Jena, Jena Univ Hosp, Dept Trauma Hand & Reconstruct Surg, D-07747 Jena, Germany
[2] BG Klinikum Bergmannstrost Halle gGmbH, Dept Sci Res & Educ, D-06112 Halle, Germany
[3] BG Klinikum Bergmannstrost Halle gGmbH, Dept Trauma & Reconstruct Surg, D-06112 Halle, Germany
[4] Friedrich Schiller Univ Jena, Jena Univ Hosp, Inst Anat 1, D-07743 Jena, Germany
[5] Martin Luther Univ Halle Wittenberg, Halle Univ Hosp, Inst Anat & Cell Biol, D-06108 Halle, Germany
[6] Fraunhofer Inst Appl Opt & Precis Engn IOF, Albert Einstein Str 7, D-07745 Jena, Germany
关键词
trauma surgery; open reduction and internal fixation; syndesmosis; upper ankle joint; syndesmotic screw; biomechanical; osteosynthesis; geriatric fracture; geriatric trauma; fibular nail; ANKLE FRACTURES; INTRAMEDULLARY FIXATION; INTERNAL-FIXATION; OPEN REDUCTION; MANAGEMENT; OUTCOMES;
D O I
10.3390/jcm12020698
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the treatment of ankle fractures, complications such as wound healing problems following open reduction and internal fixation are a major problem. An innovative alternative to this procedure offers a more minimally invasive nail stabilization. The purpose of this biomechanical study was to clarify whether this method was biomechanically comparable to the established method. First, the stability (range of motion, diastasis) and rotational stiffness of the native upper ankle were evaluated in eight pairs of native geriatric specimens. Subsequently, an unstable ankle fracture was created and fixed with a locking plate or a nail in a pairwise manner. The ankles showed significantly less stability and rotational stiffness properties after nail and plate fixations than the corresponding native ankles (p < 0.001 for all parameters). When comparing the two methods, both showed no differences in their range of motion (p = 0.694) and diastasis (p = 0.166). The nail also presented significantly greater rotational stiffness compared to the plate (p = 0.001). However, both fixations remained behind the native stability and rotational stiffness. Due to the comparable biomechanical properties of the nail and plate fixations, an early weight-bearing following nail fixation should be assessed on a case-by-case basis considering the severity of fractures.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Volar Locking Plate Versus Dorsal Locking Nail-Plate Fixation for Dorsally Displaced Unstable Extra-Articular Distal Radial Fractures
    Eikrem, Morten
    Brannsten, Hege
    Bjorkoy, Dagfinn
    Lian, Tom
    Madsen, Jan Erik
    Figved, Wender
    JBJS OPEN ACCESS, 2021, 6 (04)
  • [32] Is intrathoracic rib plate fixation advantageous over extrathoracic plating? A biomechanical cadaveric study
    Mischler, Dominic
    Schopper, Clemens
    Gasparri, Mario
    Schulz-Drost, Stefan
    Brace, Michael
    Gueorguiev, Boyko
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2022, 92 (03) : 574 - 580
  • [33] Locking Nail versus Plate Fixation in Calcaneal Fractures: Brief report on a Retrospective Analysis of Treatment Characteristics and Radiographic Correction Potential
    Stachel, N.
    Braun, B. J.
    Orth, M.
    Herath, S. C.
    Rollmann, M. F. R.
    Menger, M. M.
    Histing, T.
    Pohlemann, T.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2022, 89 (05) : 349 - 352
  • [34] Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
    Shao, Jin
    Kong, De-Ce
    Yang, Tie-Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 16230 - +
  • [35] Dynamic Compression Plate versus Locking Compression Plate Fixation in Adult Forearm Fractures: A Prospective Interventional Study
    Shevate, Ishan
    Patil, Gaurav Lalasaheb
    Salunkhe, Rahul
    Deshmukh, Ashwin
    Khandge, Ashwinkumar Vasant
    Yadav, Siddharth
    Sukrethan, Sayooj
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (08) : RC21 - RC25
  • [36] A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation
    Golish S.R.
    Oliviero J.A.
    Francke E.I.
    Miller M.D.
    Journal of Orthopaedic Surgery and Research, 3 (1)
  • [37] Locking Plate Fixation for Proximal Humerus Fractures
    Burke, Neil G.
    Kennedy, Jim
    Green, Connor
    Dodds, Michael K.
    Mullett, Hannan
    ORTHOPEDICS, 2012, 35 (02) : E250 - E254
  • [38] Biomechanical Analysis of a Novel Syndesmotic Plate Compared With Traditional Screw and Suture Button Fixation
    Weng, Qihao
    Lin, Chuanlu
    Liu, Yang
    Dai, Gaole
    Lutchooman, Vinesh
    Hong, Jianjun
    JOURNAL OF FOOT & ANKLE SURGERY, 2020, 59 (03) : 522 - 528
  • [39] Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: A biomechanical study
    Minihane, Keith P.
    Lee, Chris
    Ahn, Chulhyun
    Zhang, Li-Qun
    Merk, Bradley R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (08) : 562 - 566
  • [40] Medial Locking Plate Versus Screw Fixation for Fixation of the Ludloff Osteotomy
    Saxena, Amol
    St Louis, Marie
    JOURNAL OF FOOT & ANKLE SURGERY, 2013, 52 (02) : 153 - 157