Mass Effect After Flow Diversion for Unruptured Large and Giant Cavernous or Paraclinoid Internal Carotid Artery Aneurysm

被引:4
作者
Moon, Eunji [1 ]
Park, Wonhyoung [1 ]
Song, Yunsun [2 ]
Lee, Deok Hee [2 ]
Ahn, Jae Sung [1 ]
Park, Jung Cheol [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Neurosurg, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul, South Korea
关键词
Cerebral aneurysm; Flow diverter; Intra-aneurysmal thrombosis; Mass effect; Ophthalmoplegia; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; PIPELINE EMBOLIZATION; COILING; DEVICE;
D O I
10.1016/j.wneu.2023.08.129
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The mass effect associated with large or giant intracranial aneurysms is difficult for traditional endovascular treatment. This study investigated whether flow diverters can relieve the aneurysmal mass effect caused by aneurysmal compression symptoms.METHODS: Fifty-five patients with unruptured large and giant intracranial aneurysms treated by a flow diverter at our institution from January 2014 to February 2022 were retrospectively evaluated.RESULTS: In this study, 53 patients were included. Initially, 27 patients (51.9%), including 10 with compressive optic neuropathy, 12 with third nerve palsy, 2 with facial hyperesthesia, and 11 with sixth nerve palsy, were symptomatic. The symptom duration was shorter in the improved group (n = 2.2 +/- 4.0 vs. n = 3.1 +/- 3.9, P = 0.49). Thrombus formation following the flow diversion procedure was typically observed on magnetic resonance imaging (MRI) performed immediately and was not significantly associated with symptomatic improvement (OR = 0.395; 95% CI (0.058-2.698), P = 0.343). However, symptomatic improvement was seen in most patients when the aneurysm size decreased on MRI. A reduction in the aneurysm size on the MRI at the 3-month follow-up was correlated with symptomatic improvement in the multivariate analysis (OR = 0.08, 95% CI (0.013-0.485), P < 0.05).CONCLUSIONS: A flow diverter might help alleviate compression symptoms caused by large or giant intracranial aneurysms. Shrinkage of the aneurysm within 3 months postoperatively and a shorter duration of symp-toms contribute to the favorable outcomes of mass effect. Ultimately, prompt treatment is crucial for improving symptomatic intracranial artery aneurysms.
引用
收藏
页码:E108 / E116
页数:9
相关论文
共 50 条
[21]   Treatment for Giant Fusiform Aneurysm Located in the Cavernous Segment of the Internal Carotid Artery Using the Pipeline Embolization Device [J].
Oh, Se-yang ;
Kim, Myeong Jin ;
Kim, Bum-soo ;
Shin, Yong Sam .
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2014, 55 (01) :32-35
[22]   Flow diversion for compressive unruptured internal carotid artery aneurysms with neuro-ophthalmological symptoms: a systematic review and meta-analysis [J].
Kaiser, Daniel P. O. ;
Cuberi, Ani ;
Linn, Jennifer ;
Gawlitza, Matthias .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (09) :892-897
[23]   Ineffective endovascular treatment of a giant internal carotid artery aneurysm [J].
Brzegowy, Pawel ;
Chukwu, Ositadima ;
Ciuk, Katarzyna ;
Urbanik, Andrzej ;
Popiela, Tadeusz ;
Kwinta, Borys ;
Lasocha, Bartlomiej .
POLISH JOURNAL OF RADIOLOGY, 2020, 85 :E323-E327
[24]   A surgical case of paraclinoid carotid aneurysm associated with ipsilateral cervical internal carotid artery dissection [J].
Takeuchi, Satoru ;
Wada, Kojiro ;
Sakakibara, Fumihiro ;
Mori, Kentaro .
NEUROLOGY INDIA, 2012, 60 (05) :517-519
[25]   Timing and size of flow impingement in a giant intracranial aneurysm at the internal carotid artery [J].
Jou, Liang-Der ;
Mawad, Michel E. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (08) :891-899
[26]   Variation of Mass Effect After Using a Flow Diverter With Adjunctive Coil Embolization for Symptomatic Unruptured Large and Giant Intracranial Aneurysms [J].
Wang, Zhongxiao ;
Tian, Zhongbin ;
Li, Wenqiang ;
Wang, Jiejun ;
Zhu, Wei ;
Zhang, Mingqi ;
Zhang, Ying ;
Liu, Jian ;
Wang, Kun ;
Zhang, Yisen ;
Yang, Xinjian .
FRONTIERS IN NEUROLOGY, 2019, 10
[27]   Patency of the Anterior Choroidal Artery after Flow-Diversion Treatment of Internal Carotid Artery Aneurysms [J].
Brinjikji, W. ;
Kallmes, D. F. ;
Cloft, H. J. ;
Lanzino, G. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) :537-541
[28]   Flow diverter manages very small aneurysm of the internal carotid artery [J].
Lee, Chien-Hui ;
Luo, Chao-Bao ;
Lai, Yen-Chun ;
Chang, Feng-Chi ;
Lin, Chung-Jung .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (07) :754-758
[29]   Flow diversion of large internal carotid artery aneurysms with the surpass device: impressions and technical nuance from the initial North American experience [J].
Colby, Geoffrey P. ;
Lin, Li-Mei ;
Caplan, Justin M. ;
Jiang, Bowen ;
Michniewicz, Barbara ;
Huang, Judy ;
Tamargo, Rafael J. ;
Coon, Alexander L. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) :279-286
[30]   Contrast-induced Encephalopathy after Coil Embolization of an Unruptured Internal Carotid Artery Aneurysm [J].
Nagamine, Yuito ;
Hayashi, Takeshi ;
Kakehi, Yoshiaki ;
Yamane, Fumitaka ;
Ishihara, Shoichiro ;
Uchino, Akira ;
Tanahashi, Norio .
INTERNAL MEDICINE, 2014, 53 (18) :2133-2138