Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study

被引:4
|
作者
Fu, Shuang [1 ,2 ]
Sun, Wei [2 ]
Zhu, Jingxian [1 ,2 ]
Huang, Bin [2 ]
Ji, Wei [1 ,2 ]
Shi, Bin [1 ,2 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, State Key Lab Oral & Maxillofacial Reconstruct & R, Key Lab Oral Biomed,Minist Educ,Hubei Key Lab Stom, Wuhan, Peoples R China
[2] Wuhan Univ, Sch & Hosp Stomatol, Dept Implantol, Wuhan, Peoples R China
关键词
Fully edentulous; Computer-assisted implant surgery; Accuracy; REPORTED OUTCOME MEASURES; SURGICAL GUIDES; PLACEMENT; NAVIGATION; TEMPLATE; ERRORS;
D O I
10.1007/s00784-023-05161-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to compare implant positioning accuracy and patient-centered results between static and dynamic computer-assisted implant surgery (s-CAIS and d-CAIS) in edentulous jaws. Material and methods The current study retrospectively evaluated a total of 110 implants placed in 22 fully edentulous patients via s-CAIS or d-CAIS (n = 11). The accuracy of implant positioning was assessed by measuring the implant's angular deviation and deviation at the platform and apex from the preoperative design postoperatively. Patient-centered results, including preoperative and intraoperative patient-reported experiences and postoperative patient-reported outcomes, were extracted from the medical records. The nested t test and chi-square test were used to compare accuracy and patient-centered results between s-CAIS and d-CAIS postoperatively. Results The implants in the s-CAIS group showed significantly smaller angular deviation (2.32 +/- 1.23 degrees) than those in the d-CAIS group (3.87 +/- 2.75 degrees). In contrast, the platform and apical deviation were significantly larger in s-CAIS (1.56 +/- 1.19 mm and 1.70 +/- 1.09 mm, respectively) than d-CAIS (1.02 +/- 0.45 mm and 1.00 +/- 0.51 mm, respectively). Furthermore, the implants in the s-CAIS group deviated significantly (p < 0.001) more toward the coronal direction than those in the d-CAIS group. Notably, all patients in the s-CAIS group reported an obvious foreign body sensation during surgery, representing a significant difference from the d-CAIS group. Conclusions Compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation and less foreign body sensation. Trial registration. The retrospective study was registered on the Chinese Clinical Trial Registry on August 8th, 2022, with registration number No. ChiCTR2200062484. Clinical relevance Despite the increasing use of computer- assisted implant surgery in fully edentulous patients, clinical evidence comparing implant positioning accuracy and patient-centered results between static and dynamic CAIS systems is scarce. Our study demonstrated that compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation.
引用
收藏
页码:5427 / 5438
页数:12
相关论文
共 50 条
  • [31] The Influence of Surgical Experience and Bone Density on the Accuracy of Static Computer-Assisted Implant Surgery in Edentulous Jaws Using a Mucosa-Supported Surgical Template with a Half-Guided Implant Placement Protocol-A Randomized Clinical Study
    Kivovics, Marton
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    MATERIALS, 2020, 13 (24) : 1 - 12
  • [32] Implant failures and age at the time of surgery: A retrospective study on implant treatments in 4585 edentulous jaws
    Jemt, Torsten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 514 - 520
  • [33] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Feng, Yuzhang
    Su, Zhenya
    Mo, Anchun
    Yang, Xingmei
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [34] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Yuzhang Feng
    Zhenya Su
    Anchun Mo
    Xingmei Yang
    International Journal of Implant Dentistry, 8
  • [35] Positional accuracy during the sequence of static computer-assisted implant surgery in three alveolar ridge morphologies: An in vitro study
    Raabe, Clemens
    Abou-Ayash, Samir
    Yilmaz, Burak
    Surbek, Fiona Jennifer
    Chappuis, Vivianne
    Couso-Queiruga, Emilio
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (01): : 78 - 85
  • [36] Implant failures and age at the time of surgery: A retrospective study on implant treatment in 2915 partially edentulous jaws
    Jemt, Torsten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 686 - 692
  • [37] Accuracy of Edentulous Computer-Aided Implant Surgery as Compared to Virtual Planning: A Retrospective Multicenter Study
    Vinci, R.
    Manacorda, M.
    Abundo, R.
    Lucchina, A. G.
    Scarano, A.
    Crocetta, C.
    Lo Muzio, L.
    Gherlone, E. F.
    Mastrangelo, F.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [38] Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study
    Shusterman, Ariel
    Nashef, Rizan
    Tecco, Simona
    Mangano, Carlo
    Lerner, Henriette
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 146
  • [39] Comparison of the accuracy of implant placement using different drilling systems for static computer-assisted implant surgery: A simulation-based experimental study
    Sittikornpaiboon, Paknisa
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (04) : 635 - 643
  • [40] Comparison of Dental Surface Image Registration and Fiducial Marker Registration: An In Vivo Accuracy Study of Static Computer-Assisted Implant Surgery
    Han, Yen-Ting
    Lin, Wei-Chun
    Fan, Fang-Yu
    Chen, Chih-Long
    Lin, Chia-Cheng
    Cheng, Hsin-Chung
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)