Descemet Membrane Endothelial Keratoplasty and Descemet Stripping Only Using a 3D Visualization System

被引:1
作者
Cano-Ortiz, Antonio [1 ]
Sanchez-Ventosa, Alvaro [1 ]
Diaz-Mesa, Vanesa [1 ]
Gonzalez-Cruces, Timoteo [1 ]
Villalba-Gonzalez, Marta [1 ]
Villarrubia-Cuadrado, Alberto [1 ]
机构
[1] Hosp La Arruzafa, Dept Ophthalmol, Cordoba 14012, Spain
关键词
Descemet membrane endothelial keratoplasty; Descemet stripping only; 3D visualization; Fuchs' endothelial corneal dystrophy;
D O I
10.3390/jcm12175746
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Highlights What is known? The 3D visualization system allows the surgeon to operate in a more comfortable position than a conventional microscope. Looking at the surgical field on a large, high-definition 3D screen has advantages for surgical assistance and instructional purposes. What is new? The 3D visualization system can be successfully used for DSO procedures. Learning curve is short, as there is no training time required for successful use of 3D visualization system.Highlights What is known? The 3D visualization system allows the surgeon to operate in a more comfortable position than a conventional microscope. Looking at the surgical field on a large, high-definition 3D screen has advantages for surgical assistance and instructional purposes. What is new? The 3D visualization system can be successfully used for DSO procedures. Learning curve is short, as there is no training time required for successful use of 3D visualization system.Abstract (1) Purpose: The aim was to analyze the outcomes of Descemet's membrane endothelial keratoplasty (DMEK) and Descemet stripping only (DSO) surgeries using a glasses-assisted NGENUITY & REG; 3D visualization system (Alcon Laboratories, Fort Worth, TX, USA). (2) Methods: Five consecutive cases of DMEK surgery and four consecutive cases of DSO were performed using the NGENUITY & REG; system in this prospective study carried out at the Arruzafa Hospital, Cordoba, Spain. Only one eye from each patient received surgery. Best corrected distance visual acuity (CDVA) using EDTRS charts, central corneal thickness using the Casia II optical coherence tomograph (Tomey Co., Nagoya, Japan), and endothelial cell count using the Tomey EM-4000 (Tomey Co., Nagoya, Japan) for DMEK cases or the Nidek CEM-530 (Nidek Co., Ltd., Gamagori, Japan) specular microscopes for DSO cases were recorded preoperatively and at 1 and 3 months postsurgery. (3) Results: DMEK cases included one male and four female subjects, with a mean age of 73.6 & PLUSMN; 9.5 years. Average improvement in CDVA 3 months after surgery was 0.46 & PLUSMN; 0.16 decimal. Average change in cell count between 1 and 3 months postsurgery was 360.75 & PLUSMN; 289.38 cells/mm2. DSO cases included four female subjects, with a mean age of 64.2 & PLUSMN; 9.7 years. The average improvement in CDVA 3 months after surgery was 0.09 & PLUSMN; 0.17 decimal. All cases also had phacoemulsification carried out. He average change in cell count between 1 and 3 months after surgery was 460 & PLUSMN; 515.69 cells/mm2. There were no associated complications during surgery or the follow-up period in any of the cases. (4) Conclusions: In addition to the known benefits of the use of a 3D visualization system during surgery, the present study shows that the system can be successfully used in both DMEK and DSO procedures with a very short learning curve for the surgeon.
引用
收藏
页数:9
相关论文
共 14 条
  • [1] Agranat Joshua S, 2020, Int Ophthalmol Clin, V60, P17, DOI 10.1097/IIO.0000000000000291
  • [2] Long-term Follow-up and Complications of Stripping Descemet Membrane Without Placement of Graft in Eyes With Fuchs Endothelial Dystrophy
    Arbelaez, Juan G.
    Price, Marianne O.
    Price, Francis W., Jr.
    [J]. CORNEA, 2014, 33 (12) : 1295 - 1299
  • [3] Glasses-Assisted 3D Display System-Guided Descemet Membrane Endothelial Keratoplasty Tissue Preparation
    Borroni, Davide
    Rocha-de-Lossada, Carlos
    Bonci, Paola
    Rechichi, Miguel
    Rodriguez-Calvo-de-Mora, Marina
    Rachwani-Anil, Rahul
    Sanchez Gonzalez, Jose' Maria
    Urbinati, Facundo
    Garcia Lorente, Maria
    Vigo, Luca
    Carones, Francesco
    [J]. CORNEA, 2022, 41 (11) : 1444 - 1446
  • [4] Evaluation of Three-Dimensional Heads up Ophthalmic Surgery Demonstration From the Perspective of Surgeons and Postgraduate Trainees
    Cheng, Teck Chee
    Yahya, Maliha Farah Nurhazirah
    Mohd Naffi, Ainal Adlin
    Othman, Othmaliza
    Seng Fai, Tang
    Yong, Meng Hsien
    Wan Abdul Halim, Wan Haslina
    Mustapha, Mushawiahti
    Che Hamzah, Jemaima
    Md Din, Norshamsiah
    Bastion, Mae-Lynn Catherine
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (07) : 2285 - 2291
  • [5] Heads-up 3D vision system for retinal detachment surgery
    Michele Coppola
    Carlo La Spina
    Alessandro Rabiolo
    Giuseppe Querques
    Francesco Bandello
    [J]. International Journal of Retina and Vitreous, 3 (1)
  • [6] HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES An Experimental and Clinical Study
    Eckardt, Claus
    Paulo, Erica B.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (01): : 137 - 147
  • [7] Can the Three-Dimensional Heads-Up Display Improve Ergonomics, Surgical Performance, and Ophthalmology Training Compared to Conventional Microscopy?
    Helayel, Halah Bin
    Al-Mazidi, Sarah
    Alakeely, Adel
    [J]. CLINICAL OPHTHALMOLOGY, 2021, 15 : 679 - 686
  • [8] Melles GRJ, 2006, CORNEA, V25, P987, DOI 10.1097/01.ico.0000248385.16896.34
  • [9] 3D Visualization System in Descemet Membrane Endothelial Keratoplasty (DMEK): A Six-Month Comparison with Conventional Microscope
    Morelli, Alberto
    Ferrandina, Rosangela
    Favuzza, Eleonora
    Cennamo, Michela
    Mencucci, Rita
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [10] Heads-up Descemet Membrane Endothelial Keratoplasty Surgery: Feasibility, Surgical Duration, Complication Rates, and Comparison With a Conventional Microscope
    Panthier, Christophe
    Courtin, Romain
    Moran, Sarah
    Gatinel, Damien
    [J]. CORNEA, 2021, 40 (04) : 415 - 419