Frequency and Voltage Stabilization of Multiarea Hybrid Power System by Considering the Impact of Communication Time Delay

被引:4
|
作者
Gulzar, Muhammad Majid [1 ,2 ]
Irfan, Rasmia [3 ]
Shahid, Kamal [3 ]
Raza, Muhammad Taskeen [4 ]
Javed, Imran [5 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Control & Instrumentat Engn, Dhahran, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, IRC Renewable Energy & Power Syst IRC REPS, Dhahran, Saudi Arabia
[3] Univ Punjab, Inst Elect Elect & Comp Engn, Lahore, Pakistan
[4] Lahore Coll Women Univ, Elect Engn Dept, Lahore, Pakistan
[5] Univ Engn & Technol, Dept Elect Engn & Technol, Lahore, Pakistan
关键词
load frequency control; automatic voltage regulation; communication time delay; redox flow batteries; interline power flow controller; sine cosine algorithm; CONTROLLER; ALGORITHM; DESIGN;
D O I
10.1080/15325008.2023.2251489
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The integration of renewable energy sources (RES) with conventional sources plays a vital role in global energy systems. With the integration of RES, frequency and voltage variations are the major issues, which degrade system performance. In this study, an optimal controller is designed to mitigate these frequency and voltage variations by considering the effect of communication time delays in the multisource two-area power system. Area-1 comprises conventional generation units (i.e., thermal, hydro, and gas) whereas area-2 comprises wind, solar, and diesel power plants. Frequency oscillations are mitigated by a load frequency control loop and variations in terminal voltage are regulated by an automatic voltage regulation loop. To enhance the system response, redox flow batteries, and interline power flow controllers are integrated in the system. Moreover, physical constraints, i.e., generation rate constraint is accounted in reheat thermal and hydropower plants. The proposed sine cosine algorithm tuned Proportional Integral Derivative controller ensures that variations of frequencies, terminal voltages, and exchange of tie-line power will remain within tolerance limits. The system response on random loading is evaluated and a comparison is done with state-of-the-art controllers. As a result, the proposed controller provides better performance by minimizing the fluctuations of frequency and voltages.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Communication Resources Allocation for Time Delay Reduction of Frequency Regulation Service in High Renewable Penetrated Power System
    He, Hongjie
    Zhang, Ning
    Kang, Chongqing
    Ci, Song
    Teng, Fei
    Strbac, Goran
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2024, 10 (02): : 468 - 480
  • [32] Wide Area Predictive Control of Power System Considering Communication Delay and Data Drops
    Mahish, Priyatosh
    Pradhan, Ashok Kumar
    Sinha, Avinash Kumar
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (06) : 3243 - 3253
  • [33] A System Compensation Based Model Predictive AGC Method for Multiarea Interconnected Power Systems with High Penetration of PV System and Random Time Delay between Different Areas
    Zhao, Xilin
    He, Jingjing
    Fu, Bo
    He, Li
    Xu, Guanghui
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [34] A Distributed Frequency Regulation Method for Multi-Area Power System Considering Optimization of Communication Structure
    Wang, Yicong
    Liu, Chang
    Han, Ji
    Tan, Haoyu
    Ke, Fangchao
    Zhang, Dongyin
    Wei, Cong
    ENERGIES, 2022, 15 (18)
  • [35] Concurrent frequency-voltage stabilization for hybrid microgrid with virtual inertia support
    Latif, Abdul
    Hussain, S. M. Suhail
    Iqbal, Atif
    Das, Dulal Chandra
    Ustun, Taha Selim
    Al-Durra, Ahmed
    IET RENEWABLE POWER GENERATION, 2023, 17 (09) : 2257 - 2275
  • [36] Robust Load Frequency Control for Power System Considering Transmission Delay and Sampling Period
    Shangguan, Xing-Chen
    Zhang, Chuan-Ke
    He, Yong
    Jin, Li
    Jiang, Lin
    Spencer, Joseph
    Wu, Min
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (08) : 5292 - 5303
  • [37] Coordinated control strategy for simultaneous frequency and voltage stabilisation of the multi-area interconnected system considering communication time delays
    Kalyan, Ch Naga Sai
    Rao, Gudapati Sambasiva
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 43 (01) : 5512 - 5524
  • [38] Robust load frequency control of multi-area interconnected power system with time delay
    Zhao, Xuemao
    Sun, Yonghui
    Yuan, Chao
    Wei, Zhinong
    Sun, Guoqiang
    2015 34TH CHINESE CONTROL CONFERENCE (CCC), 2015, : 8969 - 8974
  • [39] Significance of SMES Devices for Power System Frequency Regulation Scheme considering Distributed Energy Resources in a Deregulated Environment
    Mishra, Dillip Kumar
    Zlotecka, Daria
    Li, Li
    ENERGIES, 2022, 15 (05)
  • [40] Delay-discretization-based sliding mode H∞ load frequency control scheme considering actuator saturation of wind-integrated power system
    Pradhan, Subrat Kumar
    Das, Dushmanta Kumar
    JOURNAL OF SUPERCOMPUTING, 2022, 78 (12) : 13942 - 13987