Frequency and Voltage Stabilization of Multiarea Hybrid Power System by Considering the Impact of Communication Time Delay

被引:4
|
作者
Gulzar, Muhammad Majid [1 ,2 ]
Irfan, Rasmia [3 ]
Shahid, Kamal [3 ]
Raza, Muhammad Taskeen [4 ]
Javed, Imran [5 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Control & Instrumentat Engn, Dhahran, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, IRC Renewable Energy & Power Syst IRC REPS, Dhahran, Saudi Arabia
[3] Univ Punjab, Inst Elect Elect & Comp Engn, Lahore, Pakistan
[4] Lahore Coll Women Univ, Elect Engn Dept, Lahore, Pakistan
[5] Univ Engn & Technol, Dept Elect Engn & Technol, Lahore, Pakistan
关键词
load frequency control; automatic voltage regulation; communication time delay; redox flow batteries; interline power flow controller; sine cosine algorithm; CONTROLLER; ALGORITHM; DESIGN;
D O I
10.1080/15325008.2023.2251489
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The integration of renewable energy sources (RES) with conventional sources plays a vital role in global energy systems. With the integration of RES, frequency and voltage variations are the major issues, which degrade system performance. In this study, an optimal controller is designed to mitigate these frequency and voltage variations by considering the effect of communication time delays in the multisource two-area power system. Area-1 comprises conventional generation units (i.e., thermal, hydro, and gas) whereas area-2 comprises wind, solar, and diesel power plants. Frequency oscillations are mitigated by a load frequency control loop and variations in terminal voltage are regulated by an automatic voltage regulation loop. To enhance the system response, redox flow batteries, and interline power flow controllers are integrated in the system. Moreover, physical constraints, i.e., generation rate constraint is accounted in reheat thermal and hydropower plants. The proposed sine cosine algorithm tuned Proportional Integral Derivative controller ensures that variations of frequencies, terminal voltages, and exchange of tie-line power will remain within tolerance limits. The system response on random loading is evaluated and a comparison is done with state-of-the-art controllers. As a result, the proposed controller provides better performance by minimizing the fluctuations of frequency and voltages.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Frequency stabilization of isolated and grid connected hybrid power system models
    Ganguly, Somnath
    Shiva, Chandan Kumar
    Mukherjee, V.
    JOURNAL OF ENERGY STORAGE, 2018, 19 : 145 - 159
  • [22] Frequency stabilization of hybrid power system using robust secondary controller
    Farooq, Zahid
    Rahman, Asadur
    Lone, Shameem Ahmad
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (06) : 3306 - 3326
  • [23] Impact of Electric Vehicle Aggregator with Communication Time Delay on Stability Regions and Stability Delay Margins in Load Frequency Control System
    Ausnain Naveed
    ?ahin S?nmez
    Saffet Ayasun
    JournalofModernPowerSystemsandCleanEnergy, 2021, 9 (03) : 595 - 601
  • [24] Impact of Electric Vehicle Aggregator with Communication Time Delay on Stability Regions and Stability Delay Margins in Load Frequency Control System
    Naveed, Ausnain
    Sonmez, Sahin
    Ayasun, Saffet
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (03) : 595 - 601
  • [25] Load Frequency Control of Hybrid Power System Incorporating Vehicle-to-Grid Technology Considering AC Transmission Links
    Gaur, Pushpa
    Soren, Nirmala
    Bhowmik, Debashish
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (01) : 381 - 391
  • [26] Event-Triggering Load Frequency Control for Multiarea Power Systems With Communication Delays
    Wen, Shiping
    Yu, Xinghuo
    Zeng, Zhigang
    Wang, Jinjian
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (02) : 1308 - 1317
  • [27] LMI based robust load frequency control for time delayed power system via delay margin estimation
    Xiong, Linyun
    Li, Hao
    Wang, Jie
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 100 : 91 - 103
  • [28] Computation of All Stabilizing PI Controller Parameters of Hybrid Load Frequency Control System with Communication Time Delay
    Erol, Halil
    Sezer, Halil
    Ayasun, Saffet
    2017 5TH INTERNATIONAL ISTANBUL SMART GRID AND CITIES CONGRESS AND FAIR (ICSG), 2017, : 130 - 134
  • [29] An Analytical Design Method of PI/PID Load Frequency Controllers for Single-Area Power System with Communication Network Time Delay
    Boskovic, Marko C.
    Sekara, Tomislav B.
    Rapaic, Milan R.
    2021 20TH INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2020,
  • [30] Impact of electric vehicles and realistic dish-Stirling solar thermal system on combined voltage and frequency regulation of multiarea hydrothermal system
    Dekaraja, Biswanath
    Saikia, Lalit Chandra
    ENERGY STORAGE, 2022, 4 (06)