Benefit Over Risk Assessment of CT-guided Lung Core Needle Biopsy With the Coaxial Technique

被引:1
作者
Barbiero, Giulio [1 ,4 ]
Battistel, Michele [1 ]
Pauro, Alessandro [2 ]
De Conti, Giorgio [1 ]
Calabrese, Fiorella [3 ]
Rea, Federico [3 ]
Balestro, Elisabetta [3 ]
机构
[1] Univ Hosp Padua, Dept Integrated Diagnost Serv DIDAS, Padua, Italy
[2] Santa Maria della Misericordia Hosp, Dept Diagnost Imaging, Udine, Italy
[3] Univ Padua, Dept Cardiac Thorac & Vasc Sci & Publ Hlth, Padua, Italy
[4] Univ Hosp Padua, Dept Integrated Diagnost Serv DIDAS, Via Giustiniani 2, I-35128 Padua, PD, Italy
来源
IN VIVO | 2023年 / 37卷 / 04期
关键词
Interventional radiology; core-needle biopsy; computed tomography guidance; diagnostic accuracy; complications; PULMONARY HEMORRHAGE; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; PNEUMOTHORAX; GUIDELINES; LESIONS; MANAGEMENT; SOCIETY; SAFETY; YIELD;
D O I
10.21873/invivo.13257
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Lung percutaneous needle biopsy (PNB) under CT guidance can be performed with a single-needle or with a coaxial (CX) technique. This study evaluated the CX technique in a large cohort of patients who underwent to CT-guided lung PNB in our Institute over a period of 7 years. Patients and Methods: We retrospectively collected and analyzed data relative to 700 CT-guided lung PNBs performed from August 2012 to August 2019 in 700 years) with normal coagulation and pulmonary function. PNB was considered diagnostic if at least one of the collected tissue specimens allowed for histological diagnosis. Pulmonary hemorrhage (PH) and pneumothorax (PNX) were evaluated as present or absent. Statistical analysis was made by Chi-square test of Pearson, Fisher's exact test and Wilcoxon test. Results: The CX technique showed a high diagnostic accuracy (93.0%) and allowed the collection of a great number of appropriate tissue specimens with a single pleural puncture (& GE;3 specimens in 77.4% of cases). PH was the complication more frequent (55.4%), without significant clinical impact. Global PNXs incidence was high (42.9%), but the introducer allowed to aspirate the PNX with a lower percentage of chest tube placement vs. PNXs not aspirated (6.3% and 13.3%, respectively). Conclusion: This large retrospective study confirmed the high diagnostic accuracy of lung PNB with the CX technique and allowed identification of significant factors to achieve a greater diagnostic power and decrease complication rates.
引用
收藏
页码:1703 / 1713
页数:11
相关论文
共 37 条
[1]   CT-guided lung biopsy: Factors influencing diagnostic yield and complication rate [J].
Anderson, JM ;
Murchison, J ;
Patel, D .
CLINICAL RADIOLOGY, 2003, 58 (10) :791-797
[2]   Imaging-guided chest biopsies: techniques and clinical results [J].
Anzidei, Michele ;
Porfiri, Andrea ;
Andrani, Fabrizio ;
Di Martino, Michele ;
Saba, Luca ;
Catalano, Carlo ;
Bezzi, Mario .
INSIGHTS INTO IMAGING, 2017, 8 (04) :419-428
[3]   Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance [J].
Boskovic, Tatjana ;
Stanic, Jelena ;
Pena-Karan, Slobodanka ;
Zarogoulidis, Paul ;
Drevelegas, Kostas ;
Katsikogiannis, Nikolaos ;
Machairiotis, Nikolaos ;
Mpakas, Andreas ;
Tsakiridis, Kosmas ;
Kesisis, Georgios ;
Tsiouda, Theodora ;
Kougioumtzi, Ioanna ;
Arikas, Stamatis ;
Zarogoulidis, Konstantinos .
JOURNAL OF THORACIC DISEASE, 2014, 6 :S99-S107
[4]   Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature [J].
Capalbo, Emanuela ;
Peli, Michela ;
Lovisatti, Maria ;
Cosentino, Maria ;
Mariani, Paola ;
Berti, Eisabetta ;
Cariati, Maurizio .
RADIOLOGIA MEDICA, 2014, 119 (08) :572-594
[5]   Image-guided biopsy in primary lung cancer: Why, when and how [J].
de Margerie-Mellon, C. ;
de Bazelaire, C. ;
de Kerviler, E. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (10) :965-972
[6]   Transthoracic needle biopsy of the lung: Results of early discharge in 506 outpatients [J].
Dennie, CJ ;
Matzinger, FR ;
Marriner, JR ;
Maziak, DE .
RADIOLOGY, 2001, 219 (01) :247-251
[7]   Percutaneous core needle biopsy vs. fine needle aspiration in diagnosing benign lung lesions [J].
Greif, J ;
Marmor, S ;
Schwarz, Y ;
Staroselsky, AN .
ACTA CYTOLOGICA, 1999, 43 (05) :756-760
[8]   Prevalence of incidental pulmonary nodules on computed tomography of the thorax in trauma patients [J].
Hammerschlag, G. ;
Cao, J. ;
Gumm, K. ;
Irving, L. ;
Steinfort, D. .
INTERNAL MEDICINE JOURNAL, 2015, 45 (06) :630-633
[9]   COMPLICATIONS AFTER CT-GUIDED NEEDLE-BIOPSY THROUGH AERATED VERSUS NONAERATED LUNG [J].
HARAMATI, LB ;
AUSTIN, JHM .
RADIOLOGY, 1991, 181 (03) :778-778
[10]   Complication rates of CT-guided transthoracic lung biopsy: meta-analysis [J].
Heerink, W. J. ;
de Bock, G. H. ;
de Jonge, G. J. ;
Groen, H. J. M. ;
Vliegenthart, R. ;
Oudkerk, M. .
EUROPEAN RADIOLOGY, 2017, 27 (01) :138-148