Discrete optimal quadratic AGC based cost functional minimization for interconnected power systems

被引:0
|
作者
Esmail, M. [1 ]
Krishnamurthy, S. [1 ]
机构
[1] Cape Peninsula Univ Technol, Dept Elect Elect & Comp Engn, Symphony Way, ZA-7535 Bellville, Cape Town, South Africa
基金
新加坡国家研究基金会;
关键词
AUTOMATIC-GENERATION CONTROL; LOAD-FREQUENCY CONTROL; DIFFERENTIAL EVOLUTION ALGORITHM; CONTROLLER-DESIGN; PID CONTROLLER; CONTROL STRATEGIES; INERTIA; SSSC;
D O I
10.1038/s41598-023-29317-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The increasing complexity and difficulty of the Automatic generation control (AGC) problem has resulted from the increasing scale of interconnected power networks and changing daily demands. The primary goals of AGC are to control frequency variations at nominal levels and tie-line power variances at planned levels. To effectively deal with AGC control difficulties, this study introduces Discrete Optimal Quadratic Automatic Generation Control (OQAGC). One advantages of this method is the differentiation of quadratic cost function results into linear terms while minimizing control actions and minimizing state deviations. This developed control method leads to a simple and easy discrete control law that can be implemented for both linear and nonlinear systems. For optimizing the controller, this research work utilized an optimum control theorem using Lagrangian multipliers, while the functional minimization technique is used for systematically selecting the state and control weighting matrices in discrete form for N control regions (where N is the number of interconnected power systems). The discrete cost function needs are derived using this technique in terms of area control errors, integral area control errors, and control energy expenditure. Four interconnected power systems were analyzed with/without disturbances and area control errors, each with one thermal, hydro, and gas-generating unit. A two-area multi-source power system with renewable energy in control area 2 is analyzed for the performance of the proposed controller with generation rate constraints (GRCs). The functional minimization technique simplifies and eases the choosing of weighting matrices. Furthermore, the simulation findings suggest that the developed discrete optimum quadratic AGC control-based cost functional minimization approach enhances power system dynamics in terms of stability, steady-state performance, and the closed-loop control system's robustness to input load disturbances. As a result, the newly developed OQAGC approach demonstrates the significance of the discrete LQR controller for N multi-area power systems.
引用
收藏
页数:37
相关论文
共 50 条
  • [21] PSO Tuned Combined Optimal Fuzzy Controller for AGC of Two Area Interconnected Power System
    Sinha, S. K.
    Prasad, R.
    Patel, R. N.
    2009 WORLD CONGRESS ON NATURE & BIOLOGICALLY INSPIRED COMPUTING (NABIC 2009), 2009, : 536 - +
  • [22] Optimal Control of AGC Systems Considering Non-Gaussian Wind Power Uncertainty
    Chen, Xiaoshuang
    Lin, Jin
    Liu, Feng
    Song, Yonghua
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (04) : 2730 - 2743
  • [23] Stability improvement of interconnected AC/DC multiarea AGC power systems using optimized virtual synchronous power strategy based on eigenvalues sensitivity and adaptive mixed GWO
    Tebib, Abdenour
    Boudour, Mohamed
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (04):
  • [24] Optimal fractional order fuzzy based AGC using MODA & NSGA-II to improve dynamic stability of multi-area interconnected power system
    Falehi, Ali Darvish
    Talavari, Mashallah
    Talavari, Abbas
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2019, 37 (06) : 7951 - 7964
  • [25] Application of Moth Flame Optimization Algorithm for AGC of Multi-Area Interconnected Power Systems
    Barisal, Ajit Kumar
    Lal, Deepak Kumar
    INTERNATIONAL JOURNAL OF ENERGY OPTIMIZATION AND ENGINEERING, 2018, 7 (01) : 22 - 49
  • [26] Design and analysis of optimal AGC regulator for multi-area power systems with TCPS and energy storage unit in deregulated environment
    Mishra, Ram Naresh
    Kumar, Narendra
    Chaturvedi, Devendra Kumar
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2024, 45 (04) : 1456 - 1502
  • [27] Introducing FOPLC Based TCSC in Coordination with AGC to Improve Frequency Stability of Interconnected Multi-source Power System
    Hagh, M. Tarafdar
    Morsali, J.
    Zare, K.
    Muttaqi, K. M.
    2015 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2015,
  • [28] Fractional IMC-Based AGC for Interconnected Power System via Its Reduced Model Using Genetic Algorithm
    Kasireddy, Idamakanti
    Singh, Arun Kumar
    SOFT COMPUTING IN DATA ANALYTICS, SCDA 2018, 2019, 758 : 225 - 235
  • [29] ICA assisted FTIλDN controller for AGC performance enrichment of interconnected reheat thermal power systems
    Yogendra Arya
    Journal of Ambient Intelligence and Humanized Computing, 2023, 14 : 1919 - 1935
  • [30] Comparative performance investigation of optimal controller for AGC of electric power generating systems
    Dahiya, Pankaj
    Mukhija, Pankaj
    Saxena, Anmol Ratna
    Arya, Yogendra
    AUTOMATIKA, 2016, 57 (04) : 902 - 921