Image-based robotic unicompartmental knee arthroplasty allowed to match the rotation of the tibial implant with the native kinematic knee alignment

被引:12
|
作者
Favroul, Clement [1 ]
Batailler, Cecile [1 ,2 ]
Canetti, Robin [1 ]
Shatrov, Jobe [1 ,3 ]
Zambianchi, Francesco [4 ]
Catani, Fabio [4 ]
Servien, Elvire [1 ,5 ]
Lustig, Sebastien [1 ,2 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[2] Claude Bernard Lyon 1 Univ, Univ Lyon, IFSTTAR, LBMC UMR T9406, F-69622 Lyon, France
[3] Univ Notre Dame Australia, Hornsby & Ku Ring Hosp, Sydney Orthopaed Res Inst, Sydney, NSW, Australia
[4] Univ Modena & Reggio Emilia, Azienda Osped Univ Modena, Dept Orthopaed Surg, Via Pozzo 71, I-41124 Modena, Italy
[5] Claude Bernard Lyon 1 Univ, Interuniv Lab Biol Mobil, LIBM EA 7424, Lyon, France
关键词
Unicompartmental knee arthroplasty; Image-based robotic assisted system; Screw home mechanism; Implant rotation; Kinematic alignment; FOLLOW-UP; COMPONENT; MOVEMENT; ANATOMY; BEARING;
D O I
10.1007/s00264-022-05637-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Image-based robotic tools improve the accuracy of unicompartmental knee arthroplasty (UKA) positioning, but few studies have examined its effect on axial alignment. The aim of this study was to compare the characteristics of tibial and femoral implant positioning, mainly the tibial rotation, during medial or lateral UKA, performed with an image-based robotic assisted system. Methods A total of 71 UKA performed between September 2021 and June 2022 (53 medial and 18 lateral) were analyzed. All data regarding implant positioning (rotation, coronal and sagittal alignment) for tibial and femoral components were obtained using MAKO (R) software (Stryker (R), Mahwah, USA) intra-operatively. Results The lateral UKA had a mean internal tibial rotation of 15.4 +/- 3 degrees, a mean external femoral rotation of 0.96 +/- 2.4 degrees, and a mean tibial slope of 4.7 +/- 1.3 degrees. The medial UKA had a mean internal tibial rotation of 0.18 +/- 2.7 degrees, a mean internal femoral rotation of 0.35 +/- 2.2 degrees, and a mean tibial slope of 5.4 +/- 1.3 degrees. The tibial rotations, femoral valgus, tibial varus and tibial size significantly differed between medial and lateral UKA (p < 0.05). There was no significant difference in femoral rotation, flexion, femoral size, slope, and polyethylene thickness between medial and lateral UKA. Conclusion Medial and lateral UKA had significantly different implantation characteristics related to the biomechanics of the knee compartments. Image-based robotic UKA allowed precise femorotibial positioning per-operatively to match native kinematic alignment.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [41] No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty
    Yeo, Je-Hyoung
    Seon, Jong-Keun
    Lee, Dong-Hyun
    Song, Eun-Kyoo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1142 - 1147
  • [42] No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty
    Je-Hyoung Yeo
    Jong-Keun Seon
    Dong-Hyun Lee
    Eun-Kyoo Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1142 - 1147
  • [43] Restoring tibial obliquity for kinematic alignment in total knee arthroplasty: conventional versus patient-specific instrumentation
    Smolle, Maria Anna
    Koutp, Amir
    Clar, Clemens
    Leitner, Lukas
    Leithner, Andreas
    Sadoghi, Patrick
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5867 - 5872
  • [44] A novel extramedullary technique to guide femoral bone preparation in mobile unicompartmental knee arthroplasty based on tibial cut and overall alignment
    Qidong Zhang
    Weiguo Wang
    Zhaohui Liu
    Debo Yue
    Liming Cheng
    Bailiang Wang
    Wanshou Guo
    Journal of Orthopaedic Surgery and Research, 15
  • [45] Finite Element Analysis of Mobile-bearing Unicompartmental Knee Arthroplasty: The Influence of Tibial Component Coronal Alignment
    Zhu Guang-Duo
    Guo Wan-Shou
    Zhang Qi-Dong
    Liu Zhao-Hui
    Cheng Li-Ming
    中华医学杂志英文版, 2015, 128 (21) : 2873 - 2878
  • [46] Finite Element Analysis of Mobile-bearing Unicompartmental Knee Arthroplasty: The Influence of Tibial Component Coronal Alignment
    Zhu, Guang-Duo
    Guo, Wan-Shou
    Zhang, Qi-Dong
    Liu, Zhao-Hui
    Cheng, Li-Ming
    CHINESE MEDICAL JOURNAL, 2015, 128 (21) : 2873 - 2878
  • [47] Comparison of tibial implant positioning between symmetrical and anatomical design implants in unicompartmental knee arthroplasty for Japanese patients
    Miyake, Yoshiaki
    Namba, Yoshifumi
    Mitani, Shigeru
    Umehara, Norifumi
    Kawamoto, Toyohiro
    Furuichi, Shuro
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (01)
  • [48] Reducing edge loading and alignment outliers with image-free robotic-assisted unicompartmental knee arthroplasty: a case controlled study
    Lau, Wai Hong
    Liu, Wai Kiu Thomas
    Chiu, Kwong Yuen
    Cheung, Man Hong
    Cheung, Amy
    Chan, Ping Keung
    Chan, Vincent Wai Kwan
    Fu, Henry
    ARTHROPLASTY, 2024, 6 (01)
  • [49] Fractures in Oxford unicompartmental knee arthroplasty are associated with a decreased medial keel-cortex distance of the tibial implant
    Watrinet, Julius
    Berger, Daniel
    Blum, Philipp
    Fabritius, Matthias P.
    Arnholdt, Joerg
    Schipp, Rolf
    Reng, Wolfgang
    Reidler, Paul
    KNEE SURGERY & RELATED RESEARCH, 2024, 36 (01)
  • [50] Individualized alignment in total knee arthroplasty using image-based robotic assistance: Video article; [Individualisiertes Alignment in der Knieendoprothetik mit bildbasierter Roboterassistenz: Videobeitrag]
    Calliess T.
    Ettinger M.
    Savov P.
    Karkosch R.
    Windhagen H.
    Der Orthopäde, 2018, 47 (10): : 871 - 879