Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT

被引:16
作者
Decker, Josua A. [1 ]
Becker, Judith [1 ]
Haerting, Mark [1 ]
Jehs, Bertram [1 ]
Risch, Franka [1 ]
Canalini, Luca [1 ]
Wollny, Claudia [1 ]
Scheurig-Muenkler, Christian [1 ]
Kroencke, Thomas [1 ,2 ]
Schwarz, Florian [1 ,3 ,4 ]
Bette, Stefanie [1 ]
机构
[1] Univ Augsburg, Univ Hosp Augsburg, Fac Med, Diagnost & Intervent Radiol, Stenglinstr 2, D-86156 Augsburg, Germany
[2] Univ Augsburg, Ctr Adv Analyt & Predict Sci CAAPS, Univ Str 2, D-86159 Augsburg, Germany
[3] Ludwig Maximilian Univ Munich, Med Fac, Bavariaring 19, D-80336 Munich, Germany
[4] DONAUISAR Hosp Deggendorf Dingolfing Landau, Inst Radiol, Perlasberger Str 41, D-94469 Deggendorf, Germany
关键词
Photon-counting detector computed tomography; Pancreatic ductal adenocarcinoma; Virtual monoenergetic imaging; Contrast-enhanced CT; PHASE HELICAL CT; DUAL-ENERGY CT; CANCER; LIVER; DIAGNOSIS; CONTRAST; LESIONS; TUMORS;
D O I
10.1007/s00261-023-04042-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT).Methods Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV).Results Thirty-eight patients (mean age 70.4 years +/- 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (<= 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (<= 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT.Conclusion PCD-CT VMI reconstructions (<= 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.
引用
收藏
页码:103 / 116
页数:14
相关论文
共 39 条
[11]   Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels [J].
Dillinger, Daniel ;
Overhoff, Daniel ;
Booz, Christian ;
Kaatsch, Hanns L. ;
Piechotka, Joel ;
Hagen, Achim ;
Froelich, Matthias F. ;
Vogl, Thomas J. ;
Waldeck, Stephan .
DIAGNOSTICS, 2023, 13 (05)
[12]   Optimal Virtual Monoenergetic Photon Energy (keV) for Photon-Counting-Detector Computed Tomography Angiography [J].
Dunning, Chelsea A. S. ;
Rajendran, Kishore ;
Inoue, Akitoshi ;
Rajiah, Prabhakar ;
Weber, Nikkole ;
Fletcher, Joel G. ;
McCollough, Cynthia H. ;
Leng, Shuai .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (04) :569-575
[13]   High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose [J].
Euler, Andre ;
Higashigaito, Kai ;
Mergen, Victor ;
Sartoretti, Thomas ;
Zanini, Bettina ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Ulzheimer, Stefan ;
Eberhard, Matthias ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2022, 57 (02) :115-121
[14]   Pancreatic malignancy: Value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT [J].
Fletcher, JG ;
Wiersema, MJ ;
Farrell, MA ;
Fidler, JL ;
Burgart, LJ ;
Koyama, T ;
Johnson, CD ;
Stephens, DH ;
Ward, EM ;
Harmsen, WS .
RADIOLOGY, 2003, 229 (01) :81-90
[15]   Photon-counting CT review [J].
Flohr, Thomas ;
Petersilka, Martin ;
Henning, Andre ;
Ulzheimer, Stefan ;
Ferda, Jiri ;
Schmidt, Bernhard .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 :126-136
[16]   Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm [J].
Frellesen, Claudia ;
Fessler, Freia ;
Hardie, Andrew D. ;
Wichmann, Julian L. ;
De Cecco, Carlo N. ;
Schoepf, U. Joseph ;
Kerl, J. Matthias ;
Schulz, Boris ;
Hammerstingl, Renate ;
Vogl, Thomas J. ;
Bauer, Ralf W. .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) :2052-2058
[17]   Value of Dual-Energy Computed Tomography for Detecting Small Pancreatic Ductal Adenocarcinoma [J].
Fujisaki, Yosuke ;
Fukukura, Yoshihiko ;
Kumagae, Yuichi ;
Ejima, Fumitaka ;
Yamagishi, Ryoji ;
Nakamura, Shinya ;
Kamizono, Junki ;
Kurahara, Hiroshi ;
Hashimoto, Shinichi ;
Yoshiura, Takashi .
PANCREAS, 2022, 51 (10) :1352-1358
[18]   Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT [J].
Graafen, D. ;
Muller, L. ;
Halfmann, M. ;
Duber, C. ;
Hahn, F. ;
Yang, Y. ;
Emrich, T. ;
Kloeckner, R. .
EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
[19]   Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study [J].
Hanson, G. Jay ;
Michalak, Gregory J. ;
Childs, Robert ;
McCollough, Brian ;
Kurup, Anil N. ;
Hough, David M. ;
Frye, Judson M. ;
Fidler, Jeff L. ;
Venkatesh, Sudhakar K. ;
Leng, Shuai ;
Yu, Lifeng ;
Halaweish, Ahmed F. ;
Harmsen, W. Scott ;
McCollough, Cynthia H. ;
Fletcher, J. G. .
ABDOMINAL RADIOLOGY, 2018, 43 (06) :1404-1412
[20]   Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT [J].
Higashigaito, Kai ;
Euler, Andre ;
Eberhard, Matthias ;
Flohr, Thomas G. ;
Schmidt, Bernhard ;
Alkadhi, Hatem .
ACADEMIC RADIOLOGY, 2022, 29 (05) :689-697