Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT

被引:16
作者
Decker, Josua A. [1 ]
Becker, Judith [1 ]
Haerting, Mark [1 ]
Jehs, Bertram [1 ]
Risch, Franka [1 ]
Canalini, Luca [1 ]
Wollny, Claudia [1 ]
Scheurig-Muenkler, Christian [1 ]
Kroencke, Thomas [1 ,2 ]
Schwarz, Florian [1 ,3 ,4 ]
Bette, Stefanie [1 ]
机构
[1] Univ Augsburg, Univ Hosp Augsburg, Fac Med, Diagnost & Intervent Radiol, Stenglinstr 2, D-86156 Augsburg, Germany
[2] Univ Augsburg, Ctr Adv Analyt & Predict Sci CAAPS, Univ Str 2, D-86159 Augsburg, Germany
[3] Ludwig Maximilian Univ Munich, Med Fac, Bavariaring 19, D-80336 Munich, Germany
[4] DONAUISAR Hosp Deggendorf Dingolfing Landau, Inst Radiol, Perlasberger Str 41, D-94469 Deggendorf, Germany
关键词
Photon-counting detector computed tomography; Pancreatic ductal adenocarcinoma; Virtual monoenergetic imaging; Contrast-enhanced CT; PHASE HELICAL CT; DUAL-ENERGY CT; CANCER; LIVER; DIAGNOSIS; CONTRAST; LESIONS; TUMORS;
D O I
10.1007/s00261-023-04042-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT).Methods Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV).Results Thirty-eight patients (mean age 70.4 years +/- 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (<= 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (<= 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT.Conclusion PCD-CT VMI reconstructions (<= 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.
引用
收藏
页码:103 / 116
页数:14
相关论文
共 39 条
[1]   Global surveillance of trends in cancer survival 2000-14 (CONCORD-3): analysis of individual records for 37 513 025 patients diagnosed with one of 18 cancers from 322 population-based registries in 71 countries [J].
Allemani, Claudia ;
Matsuda, Tomohiro ;
Di Carlo, Veronica ;
Harewood, Rhea ;
Matz, Melissa ;
Niksic, Maja ;
Bonaventure, Audrey ;
Valkov, Mikhail ;
Johnson, Christopher J. ;
Esteve, Jacques ;
Ogunbiyi, Olufemi J. ;
Azevedo e Silva, Gulnar ;
Chen, Wan-Qing ;
Eser, Sultan ;
Engholm, Gerda ;
Stiller, Charles A. ;
Monnereau, Alain ;
Woods, Ryan R. ;
Visser, Otto ;
Lim, Gek Hsiang ;
Aitken, Joanne ;
Weir, Hannah K. ;
Coleman, Michel P. .
LANCET, 2018, 391 (10125) :1023-1075
[2]   Progress in cancer survival, mortality, and incidence in seven high-income countries 1995-2014 (ICBP SURVMARK-2): a population-based study [J].
Arnold, Melina ;
Rutherford, Mark J. ;
Bardot, Aude ;
Ferlay, Jacques ;
Andersson, Therese M-L ;
Myklebust, Tor Age ;
Tervonen, Hanna ;
Thursfield, Vicky ;
Ransom, David ;
Shack, Lorraine ;
Woods, Ryan R. ;
Turner, Donna ;
Leonfellner, Suzanne ;
Ryan, Susan ;
Saint-Jacques, Nathalie ;
De, Prithwish ;
McClure, Carol ;
Ramanakumar, Agnihotram V. ;
Stuart-Panko, Heather ;
Engholm, Gerda ;
Walsh, Paul M. ;
Jackson, Christopher ;
Vernon, Sally ;
Morgan, Eileen ;
Gavin, Anna ;
Morrison, David S. ;
Huws, Dyfed W. ;
Porter, Geoff ;
Butler, John ;
Bryant, Heather ;
Currow, David C. ;
Hiom, Sara ;
Parkin, D. Max ;
Sasieni, Peter ;
Lambert, Paul C. ;
Moller, Bjorn ;
Soerjomataram, Isabelle ;
Bray, Freddie .
LANCET ONCOLOGY, 2019, 20 (11) :1493-1505
[3]   Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma [J].
Beer, Lucian ;
Toepker, Michael ;
Ba-Ssalamah, Ahmed ;
Schestak, Christian ;
Dutschke, Anja ;
Schindl, Martin ;
Wressnegger, Alexander ;
Ringl, Helmut ;
Apfaltrer, Paul .
EUROPEAN RADIOLOGY, 2019, 29 (07) :3617-3625
[4]   Optimal Conspicuity of Liver Metastases in Virtual Monochromatic Imaging Reconstructions on a Novel Photon-Counting Detector CT Effect of keV Settings and BMI [J].
Bette, Stefanie ;
Decker, Josua A. ;
Braun, Franziska M. ;
Becker, Judith ;
Haerting, Mark ;
Haeckel, Thomas ;
Gebhard, Michael ;
Risch, Franka ;
Woznicki, Piotr ;
Scheurig-Muenkler, Christian ;
Kroencke, Thomas J. ;
Schwarz, Florian .
DIAGNOSTICS, 2022, 12 (05)
[5]   Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT [J].
Bette, Stefanie J. ;
Braun, Franziska M. ;
Haerting, Mark ;
Decker, Josua A. ;
Luitjens, Jan H. ;
Scheurig-Muenkler, Christian ;
Kroencke, Thomas J. ;
Schwarz, Florian .
EUROPEAN RADIOLOGY, 2022, 32 (05) :2930-2936
[6]   Pancreatic-phase versus portal vein-phase helical CT of the pancreas: Optimal temporal window for evaluation of pancreatic adenocarcinoma [J].
Boland, GW ;
O'Malley, ME ;
Saez, M ;
Fernandez-del-Castillo, C ;
Warshaw, AL ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :605-608
[7]   Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data [J].
Booij, Ronald ;
van der Werf, Niels R. ;
Dijkshoorn, Marcel L. ;
van der Lugt, Aad ;
van Straten, Marcel .
DIAGNOSTICS, 2022, 12 (06)
[8]   Frequent Detection of Pancreatic Lesions in Asymptomatic High-Risk Individuals [J].
Canto, Marcia Irene ;
Hruban, Ralph H. ;
Fishman, Elliot K. ;
Kamel, Ihab R. ;
Schulick, Richard ;
Zhang, Zhe ;
Topazian, Mark ;
Takahashi, Naoki ;
Fletcher, Joel ;
Petersen, Gloria ;
Klein, Alison P. ;
Axilbund, Jennifer ;
Griffin, Constance ;
Syngal, Sapna ;
Saltzman, John R. ;
Mortele, Koenraad J. ;
Lee, Jeffrey ;
Tamm, Eric ;
Vikram, Raghunandan ;
Bhosale, Priya ;
Margolis, Daniel ;
Farrell, James ;
Goggins, Michael .
GASTROENTEROLOGY, 2012, 142 (04) :796-804
[9]   Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications [J].
D'Angelo, Tommaso ;
Cicero, Giuseppe ;
Mazziotti, Silvio ;
Ascent, Giorgio ;
Albrecht, Moritz H. ;
Martin, Simon S. ;
Othman, Ahmed E. ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1098)
[10]   Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT [J].
Decker, Josua A. ;
Bette, Stefanie ;
Lubina, Nora ;
Rippel, Katharina ;
Braun, Franziska ;
Risch, Franka ;
Wollny, Claudia ;
Scheurig-Muenkler, Christian ;
Kroencke, Thomas J. ;
Schwarz, Florian .
EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148