Serum CRP biomarker detection by using carbon nanotube field-effect transistor (CNT-FET) immunosensor

被引:35
作者
Rabbani, Gulam [1 ]
Khan, Mohammad Ehtisham [2 ]
Ahmad, Ejaz [3 ]
Khan, Mohsin Vahid [4 ]
Ahmad, Abrar [5 ]
Khan, Anwar Ulla [6 ]
Ali, Wahid [2 ]
Zamzami, Mazin A. [5 ]
Bashiri, Abdullateef H. [7 ]
Zakri, Waleed [7 ]
机构
[1] IT Med Fus Ctr, 350-27 Gumidae Ro, Gumi Si 35027, Gyeongbuk, South Korea
[2] Jazan Univ, Coll Appl Ind Technol, Dept Chem Engn Technol, Jazan 45142, Saudi Arabia
[3] Univ Michigan, Dept Pathol, Med Sch, Ann Arbor, MI 48109 USA
[4] Integral Univ, Dept Biosci, Lucknow 226026, India
[5] King Abdulaziz Univ, Fac Sci, Dept Biochem, Jeddah 21452, Saudi Arabia
[6] Jazan Univ, Coll Appl Ind Technol, Dept Elect Engn Technol, Jazan 45142, Saudi Arabia
[7] Jazan Univ, Coll Engn, Dept Mech Engn, POB 114, Jazan 45142, Saudi Arabia
关键词
Antigen-antibody; Carbon nanotubes; C-reactive protein; Field-effect transistor; Immunosensor; C-REACTIVE PROTEIN; CARDIOVASCULAR-DISEASE; RAMAN-SPECTROSCOPY; IONIC-STRENGTH; MARKERS; INFLAMMATION; ASSOCIATION; PREDICTION; CARE; PH;
D O I
10.1016/j.bioelechem.2023.108493
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
C-reactive protein (CRP) is produced by the liver in response to systemic inflammation caused by bacterial infection, trauma and internal organ failures. CRP serves as a potential biomarker in the precise diagnosis of cardiovascular risk, type-2 diabetes, metabolic syndrome, hypertension and various types of cancers. The pathogenic conditions indicated above are diagnosed by an elevated CRP level in the serum. In this study, we successfully fabricated a highly sensitive and selective carbon nanotube field-effect transistor (CNT-FET) immunosensor for the detection of CRP. The CNTs were deposited on the Si/SiO2 surface, between source-drain electrodes, afterwards modified with well-known linker PBASE and then anti-CRP was immobilized. This antiCRP functionalized CNT-FET immunosensor exhibits a wide dynamic detection range (0.01-1000 & mu;g/mL) CRP detection, rapid response time (2-3 min) and low variation (<3 %) which can be delivered as a low-cost and rapid clinical detection technology for the early diagnosis of coronary heart disease (CHD). For the clinical applications, our sensor was tested using CRP fortified serum samples and sensing performance was validated using enzyme-linked immune-sorbent assay (ELISA). This CNT-FET immunosensor will be helpful in taking over the complex laboratory-based expensive traditional CRP diagnostic procedures practiced in the hospitals.
引用
收藏
页数:11
相关论文
共 50 条
[41]   Bundling effect of semiconductor-enriched single-walled carbon nanotube networks on field-effect transistor performance [J].
Seo, Juyeon ;
Park, Seung Hun ;
Li, Jianlin ;
Hong, Sanghyun ;
Kim, Young Lae ;
Cho, Byungjin ;
Choi, Hak Soo ;
Jung, Yung Joon .
MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2025, 187
[42]   Gate dielectric material dependence of current-voltage characteristics of ballistic Schottky barrier graphene nanoribbon field-effect transistor and carbon nanotube field-effect transistor for different channel lengths [J].
Ahmed, Sheikh ;
Shawkat, Mashiyat ;
Chowdhury, Md. Iramul ;
Mominuzzaman, Sharif .
Micro & Nano Letters, 2015, 10 (10) :523-527
[43]   The optimal ionic concentration of sensing buffer in the detection of RNA by using the DNA probe with the silicon nanowire field-effect transistor (SiNW-FET) [J].
Hu, Wen-Pin ;
Wang, Jui-Shen ;
Chiu, Yu-Peng ;
Huang, Tzu-Chen ;
Yadlapalli, Bharath Kumar ;
Chen, Wen-Yih .
TALANTA, 2025, 295
[44]   Label-free protein detection based on vertically aligned carbon nanotube gated field-effect transistors [J].
Croce, Robert A., Jr. ;
Vaddiraju, Sagar ;
Chan, Pik-Yiu ;
Seyta, Rea ;
Jain, Faquir C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) :154-160
[45]   PVT variations of a behaviorally modeled single walled carbon nanotube field-effect transistor (SW-CNTFET) [J].
Agrawal, Kajari R. ;
Sonkusare, Reena .
2015 INTERNATIONAL CONFERENCE ON NASCENT TECHNOLOGIES IN THE ENGINEERING FIELD (ICNTE), 2015,
[46]   Single-walled carbon-nanotube spectroscopic and electronic field-effect transistor measurements: A combined approach [J].
Kauffman, Douglas R. ;
Star, Alexander .
SMALL, 2007, 3 (08) :1324-1329
[47]   Electrolyte-Gated Carbon Nanotube Field-Effect Transistor-Based Sensors for Nanoplastics Detection in Seawater: A Study of the Interaction between Nanoplastics and Carbon Nanotubes [J].
Elli, Giulia ;
Ciocca, Manuela ;
Shkodra, Bajramshahe ;
Petrelli, Mattia ;
Costa Angeli, Martina Aurora ;
Altana, Antonio ;
Carzino, Riccardo ;
Fragouli, Despina ;
Petti, Luisa ;
Lugli, Paolo .
ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (29) :38768-38779
[48]   SnO2/Carbon Nanotube Floating-Gate Field-Effect Transistor Gas Sensor for ppb-Level CO Detection [J].
Huang, Yao ;
Zhou, Yun ;
Liu, Yiwei ;
Chen, Junyu ;
Wei, Xiaolin ;
Cao, Juexian .
ACS APPLIED NANO MATERIALS, 2024, 7 (14) :16119-16126
[49]   Specific pH Sensor Based on Nitrogen/Carbon Nanotube-Modified Commercial Field-Effect Transistor for Detection of Rumen pH in Ruminants In Situ [J].
Doroodmand, Mohammad Mahdi ;
Nemati, Yousef ;
Mohebbi-Fani, Mehdi .
IEEE SENSORS JOURNAL, 2016, 16 (09) :2906-2913
[50]   Tungsten oxide thin film field-effect transistor based real-time sensing system for non-invasive oral cancer biomarker detection [J].
Sharma, Sumit ;
Kar, Debashree ;
Moudgil, Akshay ;
Das, Samaresh ;
Mishra, Prashant .
SENSORS AND ACTUATORS B-CHEMICAL, 2024, 407