Serum CRP biomarker detection by using carbon nanotube field-effect transistor (CNT-FET) immunosensor

被引:27
|
作者
Rabbani, Gulam [1 ]
Khan, Mohammad Ehtisham [2 ]
Ahmad, Ejaz [3 ]
Khan, Mohsin Vahid [4 ]
Ahmad, Abrar [5 ]
Khan, Anwar Ulla [6 ]
Ali, Wahid [2 ]
Zamzami, Mazin A. [5 ]
Bashiri, Abdullateef H. [7 ]
Zakri, Waleed [7 ]
机构
[1] IT Med Fus Ctr, 350-27 Gumidae Ro, Gumi Si 35027, Gyeongbuk, South Korea
[2] Jazan Univ, Coll Appl Ind Technol, Dept Chem Engn Technol, Jazan 45142, Saudi Arabia
[3] Univ Michigan, Dept Pathol, Med Sch, Ann Arbor, MI 48109 USA
[4] Integral Univ, Dept Biosci, Lucknow 226026, India
[5] King Abdulaziz Univ, Fac Sci, Dept Biochem, Jeddah 21452, Saudi Arabia
[6] Jazan Univ, Coll Appl Ind Technol, Dept Elect Engn Technol, Jazan 45142, Saudi Arabia
[7] Jazan Univ, Coll Engn, Dept Mech Engn, POB 114, Jazan 45142, Saudi Arabia
关键词
Antigen-antibody; Carbon nanotubes; C-reactive protein; Field-effect transistor; Immunosensor; C-REACTIVE PROTEIN; CARDIOVASCULAR-DISEASE; RAMAN-SPECTROSCOPY; IONIC-STRENGTH; MARKERS; INFLAMMATION; ASSOCIATION; PREDICTION; CARE; PH;
D O I
10.1016/j.bioelechem.2023.108493
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
C-reactive protein (CRP) is produced by the liver in response to systemic inflammation caused by bacterial infection, trauma and internal organ failures. CRP serves as a potential biomarker in the precise diagnosis of cardiovascular risk, type-2 diabetes, metabolic syndrome, hypertension and various types of cancers. The pathogenic conditions indicated above are diagnosed by an elevated CRP level in the serum. In this study, we successfully fabricated a highly sensitive and selective carbon nanotube field-effect transistor (CNT-FET) immunosensor for the detection of CRP. The CNTs were deposited on the Si/SiO2 surface, between source-drain electrodes, afterwards modified with well-known linker PBASE and then anti-CRP was immobilized. This antiCRP functionalized CNT-FET immunosensor exhibits a wide dynamic detection range (0.01-1000 & mu;g/mL) CRP detection, rapid response time (2-3 min) and low variation (<3 %) which can be delivered as a low-cost and rapid clinical detection technology for the early diagnosis of coronary heart disease (CHD). For the clinical applications, our sensor was tested using CRP fortified serum samples and sensing performance was validated using enzyme-linked immune-sorbent assay (ELISA). This CNT-FET immunosensor will be helpful in taking over the complex laboratory-based expensive traditional CRP diagnostic procedures practiced in the hospitals.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1
    Zamzami, Mazin A.
    Rabbani, Gulam
    Ahmad, Abrar
    Basalah, Ahmad A.
    Al-Sabban, Wesam H.
    Ahn, Saeyoung Nate
    Choudhry, Hani
    BIOELECTROCHEMISTRY, 2022, 143
  • [2] Characteristics of a Label-Less Electrochemical Immunosensor Based on a Field-Effect Transistor for the Detection of a Biomarker in Urine
    Sohn, Young-Soo
    Kim, Chang-Kyu
    Choi, Sie-Young
    SENSOR LETTERS, 2009, 7 (04) : 640 - 643
  • [3] Ultrasensitive Stress Biomarker Detection Using Polypyrrole Nanotube Coupled to a Field-Effect Transistor
    Kim, Kyung Ho
    Lee, Sang Hun
    Seo, Sung Eun
    Bae, Joonwon
    Park, Seon Joo
    Kwon, Oh Seok
    MICROMACHINES, 2020, 11 (04)
  • [4] Ultrasensitive detection of organophosphate insecticides by carbon nanotube field-effect transistor
    Ishii, Atsushi
    Takeda, Seiji
    Hattori, Satoshi
    Sueoka, Kazuhisa
    Mukasa, Koichi
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 313 : 456 - 460
  • [5] Selective Protein Sensing Using a Carbon Nanotube Field-Effect Transistor
    Abe, Masuhiro
    Murata, Kastuyuki
    Ataka, Tatsuaki
    Ifuku, Yasuo
    Matsumoto, Kazuhiko
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (03) : 1947 - 1950
  • [6] Carbon Nanotube Field-Effect Transistor for DNA Sensing
    Xuan, Chu T.
    Thuy, Nguyen T.
    Luyen, Tran T.
    Huyen, Tran T. T.
    Tuan, Mai A.
    JOURNAL OF ELECTRONIC MATERIALS, 2017, 46 (06) : 3507 - 3511
  • [7] Carbon Nanotube Field-Effect Transistor for DNA Sensing
    Chu T. Xuan
    Nguyen T. Thuy
    Tran T. Luyen
    Tran T. T. Huyen
    Mai A. Tuan
    Journal of Electronic Materials, 2017, 46 : 3507 - 3511
  • [8] A small signal model for Carbon Nanotube Field-Effect Transistor
    Zhang, Yuming
    Yang, Tao
    Yang, Yang
    Xia, Lei
    Xu, Ruimin
    2018 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC), 2018, : 366 - 368
  • [9] Carbon nanotube field-effect transistor based pH sensors
    Wang, Kemin
    Liu, Xiaofeng
    Zhao, Zijun
    Li, Luyao
    Shang, Qian
    Liu, Yiwei
    Zhang, Zhiyong
    CARBON, 2023, 205 : 540 - 545
  • [10] Study on displacement damage effect of highly charged ions in carbon nanotube field-effect transistor
    Yang, Xirong
    Zeng, Jian
    Liu, Jie
    Zhang, Shengxia
    Zhang, Hongda
    Gao, Shifan
    Zhai, Pengfei
    Cai, Li
    Hu, Peipei
    Liu, Li
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 552