Tensile strengths of super high-strength steel strand wire ropes and wire rope open swaged socket connections at fire and post fire

被引:2
作者
Yamaguchi, Takumi [1 ]
Ozaki, Fuminobu [1 ]
机构
[1] Nagoya Univ, Grad Sch Environm Studies, Nagoya, Japan
基金
日本学术振兴会;
关键词
Steel strand wire rope; Open swaged socket connection; Tensile strength at fire and post fire; Steady-state test; Transient-state test; Tensile test after heating and cooling process; TRANSIENT TEMPERATURE DISTRIBUTION; MECHANICAL-PROPERTIES; CABLES; LOADS;
D O I
10.1108/JSFE-01-2023-0013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PurposeThe main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections at fire and post fire.Design/methodology/approachSteady-state tests from ambient temperature (20 degrees C) to 800 degrees C, transient-state tests under the allowable design tensile force and tensile tests in an ambient temperature environment after heating (heating temperatures of 200-800 degrees C) were conducted.FindingsThe tensile strengths of the wire rope and end-connection specimens at both fire and post fire were obtained. The steel wire rope specimens possessed larger reduction factors than general hot-rolled mild steels (JIS SS400) and high-strength steel bolts (JIS F10T). The end-connection specimens with sufficient socket lengths exhibited ductile fracture of the wire rope part at both fire and post fire; however, those with short socket lengths experienced a pull-out fracture at the socket.Originality/valueThe fundamental and important tensile test results of the super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections were accumulated at fire and post fire, and the fracture modes were clarified. The obtained test results contribute to fire resistance performance-based design of cable steel structures at fire and fire-damage investigations to consider their reusability post fire.
引用
收藏
页码:50 / 75
页数:26
相关论文
共 19 条
[1]  
[Anonymous], 2017, NRC and AIJ, P5
[2]  
Architectural Institute of Japan (AIJ), 2004, GUID BOOK FIR RES PE
[3]  
Architectural Institute of Japan (AIJ), 2019, AIJ REC DES CABL STR
[4]   Effect of cavity radiation on transient temperature distribution in steel cables under ISO834 fire [J].
Du, Yong ;
Sun, Ya-kai ;
Jiang, Jian ;
Li, Guo-Qiang .
FIRE SAFETY JOURNAL, 2019, 104 :79-89
[5]   Transient temperature distribution in pre-tensioned anchors of cable-supported structures under ISO834 fire [J].
Du, Yong ;
Zhu, Yu ;
Jiang, Jian ;
Li, Guo-Qiang .
THIN-WALLED STRUCTURES, 2019, 138 :231-242
[6]   Mechanical properties of high tensile steel cables at elevated temperatures [J].
Du, Yong ;
Peng, Jing-Zhan ;
Liew, J. Y. Richard ;
Li, Gou-Qiang .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 182 :52-65
[7]   Study on mechanical properties of locked coil wire rope under and post fire [J].
Guo, Liulu ;
Chen, Zhihua ;
Liu, Hongbo ;
Meng, Yadan ;
Zhang, Fan ;
Wang, Longxuan .
CONSTRUCTION AND BUILDING MATERIALS, 2022, 351
[8]   Tensile and shear strength for a self-drilling screw and transition of failure-modes and shear-strengths for self-drilling screwed connections at elevated-temperatures [J].
Ozaki, Fuminobu ;
Liu, Ying ;
Ye, Kai .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (03) :321-346
[9]   Effect of temperature on the mechanical properties of low relaxation seven-wire prestressing strand [J].
Shakya, A. M. ;
Kodur, V. K. R. .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 124 :74-84
[10]  
Sun G., 2019, CONSTR BUILD MATER, V233