Real-time biosensor application of structurally chiral medium for detection and sensing of plasma in human blood

被引:1
|
作者
Ghorani, Nadia [1 ]
Madani, Amir [1 ]
Entezar, Samad Roshan [2 ]
机构
[1] Univ Bonab, Dept Laser & Opt Engn, Bonab, Iran
[2] Univ Tabriz, Fac Phys, Tabriz, Iran
关键词
structurally chiral medium; blood plasma; circularly polarized light; photonic bandgap; transfer matrix method; biosensor; LABEL-FREE DETECTION; PHOTONIC CRYSTAL; WHOLE-BLOOD; WAVE-GUIDE; REFLECTION; SENSOR; PLATFORM; OPTICS; LIGHT; BAND;
D O I
10.1088/1402-4896/accc5c
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this work, we theoretically investigated a unique and sensitive optical biosensor for detecting and sensing blood plasma using a structurally chiral medium. The proposed biosensor is a defective one-dimensional structure made from a structurally chiral material with (4) over bar 2m point group symmetry where the defect layer is considered as a channel for the blood plasma. The transmission and reflection of the structure are investigated utilizing the transfer matrix method for the circularly polarized waves. It is shown that a defect mode is created in the middle of the circular Bragg photonic band gap for the right-handed circularly polarized waves and experiences a red shift by increasing the blood plasma concentration. Also, it is observed that the sensitivity of the sensor can be increased by increasing the thickness of the defect layer. In addition, we reveal that the increase of the tilt angle of the structurally chiral medium results in the decrease of photonic band gap width and causes to blue-shift of the defect mode. As a result, the performance of the sensor decreases by increasing the tilt angle. The proposed structure has an easy and efficient manufacturing process, high stability and cost-effectiveness and can provide real-time blood plasma biosensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Real-Time Detection of Yeast Growth on Solid Medium through Passive Microresonator Biosensor
    Shi, Bo-Wen
    Zhao, Jun-Ming
    Wang, Yi-Ke
    Wang, Yan-Xiong
    Jiang, Yan-Feng
    Yang, Gang-Long
    Wang, Jicheng
    Qiang, Tian
    BIOSENSORS-BASEL, 2024, 14 (05):
  • [2] Real-time detection of plasma ferritin by electrochemical biosensor developed for biomedical analysis
    Gautam, Neha
    Chattopadhyay, Sudip
    Kar, Shantimoy
    Sarkar, Arnab
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [3] Solid-medium-integrated impedimetric biosensor for real-time monitoring of microorganisms
    Choi, Ahmi
    Park, Jae-Sung
    Jung, Hyo-Il
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01): : 357 - 362
  • [4] Development of a microelectrochemical biosensor for the real-time detection of choline
    Baker, Keeley L.
    Bolger, Fiachra B.
    Lowry, John P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 412 - 420
  • [5] Real-Time Detection of Markers in Blood
    Na, Jukwan
    Hong, Min-Ho
    Choi, Jun Shik
    Kwak, Hankyul
    Song, Seungwoo
    Kim, Hyoseok
    Chae, Youngcheol
    Cheong, Eunji
    Lee, Ju Hee
    Lim, Yong-beom
    Choi, Heon-Jin
    NANO LETTERS, 2019, 19 (04) : 2291 - 2298
  • [6] Approaching near real-time biosensing: Microfluidic microsphere based biosensor for real-time analyte detection
    Cohen, Noa
    Sabhachandani, Pooja
    Golberg, Alexander
    Konry, Tania
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 454 - 460
  • [7] Application of a real-time biosensor to detect bacteria in platelet concentrates
    Rotman, B
    Cote, MA
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 300 (01) : 197 - 200
  • [8] Application of a Plasmonic Biosensor for Detection of Human Blood Groups
    Popescu, V. A.
    PLASMONICS, 2017, 12 (06) : 1733 - 1739
  • [9] Integration of the Real-Time Remote Wireless Sensing System for Glucose Flexible Biosensor
    Chen, Jie-Ting
    Chou, Jung-Chuan
    Liao, Yi-Hung
    Chou, Hsueh-Tao
    Lin, Chin-Yi
    Chen, Jia-Liang
    WORLD CONGRESS ON ENGINEERING - WCE 2013, VOL II, 2013, : 1097 - 1101
  • [10] A simple microfluidics for real-time plasma separation and hCG detection from whole blood
    Hung, Min-Sheng
    Chang, Hsiao-Yun
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2015, 38 (06) : 685 - 691