Label-free electrochemical aptasensor based on gold nanoparticles/titanium carbide MXene for lead detection with its reduction peak as index signal

被引:142
作者
Zhang, Zhouxiang [1 ]
Karimi-Maleh, Hassan [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Resources & Environm, Xiyuan Ave, Chengdu 611731, Peoples R China
关键词
Pb2+; Label-free; Electrochemical aptasenor; AuNPs; Ti3C2-MXene; SURFACE-PLASMON RESONANCE; ION; PB2+; NANOCRYSTALS; NANOSHEETS; CAPACITY; REMOVAL; SENSOR;
D O I
10.1007/s42114-023-00652-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Lead (Pb2+) is a common heavy metallic pollutant in the environment with severe side-effects, and it can lead to chronic poisoning towards humans. Hence, the monitoring of Pb2+ in environments is highly important as a dangerous water pollutant by a simple method. In this research, a label-free electrochemical aptamer sensor (aptasensor) based on the gold nanoparticles/titanium carbide (AuNPs/Ti3C2-MXene) with an interesting strategy: the reduction peak of Pb2+ as the index signal was prepared for Pb2+ detection. According to characterization results, Ti3C2-MXene nanosheets display an excellent supporting base with uniform distribution of the AuNPs without any aggregation, which is beneficial for the immobilization of Pb2+ aptamer. Besides, the sensing interface of the developed aptasensor was constructed by the stepwise assembly of Ti3C2-MXene, AuNPs, and thiol-modified aptamer of Pb2+. On interaction with Pb2+, the Pb2+ aptamer on the electrode surface generates a conformational change from a single-stranded oligonucleotide, resulting in a G-quadruplex stable structure. After that, Pb2+ can be successfully captured, and reduction peak currents can be directly detected by the negative scan of square wave voltammetry (NSSWV). Under optimal experimental conditions, the reduction peak currents of Pb2+ displayed a good linear relationship with the logarithm of Pb2+ concentrations from 5 x 10(-7) to 3 x 10(-4) M, and its detection limit was estimated to be 3 x 10(-7) M. In addition, the prepared aptasensor exhibited excellent repeatability, good stability, high selectivity, and high reproducibility, indicating its great potential for Pb2+ environmental monitoring with recovery range 96.97-108.03%.
引用
收藏
页数:11
相关论文
共 65 条
[11]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[12]   First label-free impedimetric aptasensor based on Au NPs/TiO2 NPs for the determination of leptin [J].
Erkmen, Cem ;
Tig, Gozde Aydogdu ;
Uslu, Bengi .
SENSORS AND ACTUATORS B-CHEMICAL, 2022, 358
[13]   A review: Aptamer-based analytical strategies using the nanomaterials for environmental and human monitoring of toxic heavy metals [J].
Farzin, Leila ;
Shamsipur, Mojtaba ;
Sheibani, Shahab .
TALANTA, 2017, 174 :619-627
[14]   Utilization of Chitosan-Based Sensor Thin Films for the Detection of Lead Ion by Surface Plasmon Resonance Optical Sensor [J].
Fen, Yap Wing ;
Yunus, W. Mahmood Mat .
IEEE SENSORS JOURNAL, 2013, 13 (05) :1413-1418
[15]   A high-performance aptasensor for mercury(II) based on the formation of a unique ternary structure of aptamer-Hg2+-neutral red [J].
Gao, Cai ;
Wang, Qingxiang ;
Gao, Feng ;
Gao, Fei .
CHEMICAL COMMUNICATIONS, 2014, 50 (66) :9397-9400
[16]   Label-free electrochemical lead (II) aptasensor using thionine as the signaling molecule and graphene as signal-enhancing platform [J].
Gao, Feng ;
Gao, Cai ;
He, Suyu ;
Wang, Qingxiang ;
Wu, Aiqun .
BIOSENSORS & BIOELECTRONICS, 2016, 81 :15-22
[17]   Plasmonic Semiconductor Nanocrystals as Chemical Sensors: Pb2+ Quantitation via Aggregation-Induced Plasmon Resonance Shift [J].
Guo, Moran ;
Law, Wing-Cheung ;
Liu, Xin ;
Cai, Hongxin ;
Liu, Liwei ;
Swihart, Mark T. ;
Zhang, Xihe ;
Prasad, Paras N. .
PLASMONICS, 2014, 9 (04) :893-898
[18]   A Tramadol Drug Electrochemical Sensor Amplified by Biosynthesized Au Nanoparticle Using Mentha aquatic Extract and Ionic Liquid [J].
Hojjati-Najafabadi, Akbar ;
Salmanpour, Sadegh ;
Sen, Fatih ;
Asrami, Padideh Naderi ;
Mahdavian, Majid ;
Khalilzadeh, Mohammad A. .
TOPICS IN CATALYSIS, 2022, 65 (5-6) :587-594
[19]   Determination of tert-Butylhydroquinone Using a Nanostructured Sensor Based on CdO/SWCNTs and ionic liquid [J].
Hojjati-Najafabadi, Akbar ;
Rahmanpour, Mahbobe S. ;
Karimi, Fatemeh ;
Zabihi-Feyzaba, Hoda ;
Malekmohammad, Samira ;
Agarwal, Shilpi ;
Gupta, Vinod Kumar ;
Khalilzadeh, Mohammad A. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (07) :6969-6980
[20]   Two-dimensional Sc2C: A reversible and high-capacity hydrogen storage material predicted by first-principles calculations [J].
Hu, Qianku ;
Wang, Haiyan ;
Wu, Qinghua ;
Ye, Xiaotao ;
Zhou, Aiguo ;
Sun, Dandan ;
Wang, Libo ;
Liu, Baozhong ;
He, Julong .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (20) :10606-10612