Optimized flip angle schemes for the split acquisition of fast spin-echo signals (SPLICE) sequence and application to diffusion-weighted imaging

被引:2
|
作者
Rahbek, Sofie [1 ]
Schakel, Tim [2 ]
Mahmood, Faisal [3 ,4 ]
Madsen, Kristoffer H. H. [5 ,6 ]
Philippens, Marielle E. P. [2 ]
Hanson, Lars G. G. [1 ,5 ,7 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Lyngby, Denmark
[2] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[3] Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark
[4] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[5] Copenhagen Univ Hosp, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hvidovre, Denmark
[6] Tech Univ Denmark, Dept Appl Math & Comp Sci, Lyngby, Denmark
[7] Tech Univ Denmark, Bldg 349, DK-2800 Lyngby, Denmark
关键词
diffusion-weighted magnetic resonance imaging; point spread function; SNR; SPLICE; sequence optimization; variable flip angle; MRI; SENSITIVITY; MODULATION; HYPERECHO; TRAINS; BRAIN;
D O I
10.1002/mrm.29545
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe diffusion-weighted SPLICE (split acquisition of fast spin-echo signals) sequence employs split-echo rapid acquisition with relaxation enhancement (RARE) readout to provide images almost free of geometric distortions. However, due to the varying T2$$ {}_2 $$-weighting during k-space traversal, SPLICE suffers from blurring. This work extends a method for controlling the spatial point spread function (PSF) while optimizing the signal-to-noise ratio (SNR) achieved by adjusting the flip angles in the refocusing pulse train of SPLICE. MethodsAn algorithm based on extended phase graph (EPG) simulations optimizes the flip angles by maximizing SNR for a flexibly chosen predefined target PSF that describes the desired k-space density weighting and spatial resolution. An optimized flip angle scheme and a corresponding post-processing correction filter which together achieve the target PSF was tested by healthy subject brain imaging using a clinical 1.5 T scanner. ResultsBrain images showed a clear and consistent improvement over those obtained with a standard constant flip angle scheme. SNR was increased and apparent diffusion coefficient estimates were more accurate. For a modified Hann k-space weighting example, considerable benefits resulted from acquisition weighting by flip angle control. ConclusionThe presented flexible method for optimizing SPLICE flip angle schemes offers improved MR image quality of geometrically accurate diffusion-weighted images that makes the sequence a strong candidate for radiotherapy planning or stereotactic surgery.
引用
收藏
页码:1469 / 1480
页数:12
相关论文
共 49 条
  • [21] Comparison of diffusion-weighted imaging and T2-weighted single shot fast spin-echo: Implications for LI-RADS characterization of hepatocellular carcinoma
    Hicks, Robert M.
    Yee, Judy
    Ohliger, Michael A.
    Weinstein, Stefanie
    Kao, Jeffrey
    Ikram, Nabia S.
    Hope, Thomas A.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (07) : 915 - 921
  • [22] Intravoxel Incoherent Motion in Normal Pituitary Gland: Initial Study with Turbo Spin-Echo Diffusion-Weighted Imaging
    Kamimura, K.
    Nakajo, M.
    Fukukura, Y.
    Iwanaga, T.
    Saito, T.
    Sasaki, M.
    Fujisaki, T.
    Takemura, A.
    Okuaki, T.
    Yoshiura, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2328 - 2333
  • [23] Changes in the ADC of diffusion-weighted MRI with the oscillating gradient spin-echo (OGSE) sequence due to differences in substrate viscosities
    Maekawa, Tomoko
    Hori, Masaaki
    Murata, Katsutoshi
    Feiweier, Thorsten
    Fukunaga, Issei
    Andica, Christina
    Hagiwara, Akifumi
    Kamagata, Koji
    Koshino, Saori
    Abe, Osamu
    Aoki, Shigeki
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (07) : 415 - 420
  • [24] Diffusion-Weighted Imaging in Patients With Acute Brain Ischemia at 3 T Current Possibilities and Future Perspectives Comparing Conventional Echoplanar Diffusion-Weighted Imaging and Fast Spin Echo Diffusion-Weighted Imaging Sequences Using BLADE (PROPELLER)
    Fries, Peter
    Runge, Val M.
    Kirchin, Miles A.
    Stemmer, Alto
    Naul, L. Gill
    Williams, Kenneth D.
    Reith, Wolfgang
    Buecker, Arno
    Schneider, Guenther
    INVESTIGATIVE RADIOLOGY, 2009, 44 (06) : 351 - 359
  • [25] Variable Flip Angle Three-Dimensional Fast Spin-Echo Sequence Combined With Outer Volume Suppression for Imaging Trabecular Bone Structure of the Proximal Femur
    Han, Misung
    Chiba, Ko
    Banerjee, Suchandrima
    Carballido-Gamio, Julio
    Krug, Roland
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (05) : 1300 - 1310
  • [26] MULTISLAB 3-DIMENSIONAL T2-WEIGHTED FAST SPIN-ECHO IMAGING OF THE HIPPOCAMPUS - SEQUENCE OPTIMIZATION
    MURAKAMI, JW
    WEINBERGER, E
    TSURUDA, JS
    MITCHELL, JD
    YUAN, C
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 309 - 315
  • [27] Evaluation of apparent diffusion coefficient of two-dimensional BLADE turbo gradient- and spin-echo diffusion-weighted imaging with a breast phantom
    Ohki, Akiko
    Sagawa, Hajime
    Iima, Mami
    Kataoka, Masako
    Fushimi, Yasutaka
    Zhou, Kun
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (01) : 118 - 126
  • [28] Turbo Spin-echo Diffusion-weighted Imaging Compared with Single-shot Echo-planar Diffusion-weighted Imaging: Image Quality and Diagnostic Performance When Differentiating between Ductal Carcinoma in situ and Invasive Ductal Carcinoma
    Mori, Naoko
    Mugikura, Shunji
    Miyashita, Minoru
    Mori, Yu
    Maekawa, Yui
    Nagasaka, Tatsuo
    Takase, Kei
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 60 - 68
  • [29] Increased Speed and Image Quality for Pelvic Single-Shot Fast Spin-Echo Imaging with Variable Refocusing Flip Angles and Full-Fourier Acquisition
    Loening, Andreas M.
    Litwiller, Daniel V.
    Saranathan, Manojkumar
    Vasanawala, Shreyas S.
    RADIOLOGY, 2017, 282 (02) : 561 - 568
  • [30] BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence
    Fujimoto, Koji
    Koyama, Takashi
    Tamai, Ken
    Morisawa, Nobuko
    Okada, Tomohisa
    Togashi, Kaori
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : 796 - 801