Fabrication of Hybrid Mach-Zehnder Interferometer based on Hollow-Core Photonic Crystal Fiber for Load Measurement

被引:4
|
作者
Mohammed, Faraqid Q. [1 ]
Mansoor, Tahreer S. [2 ]
Aydi, Yassine [3 ]
机构
[1] Bilad Al Rafidain Univ Coll, Dept Comp Tech Engn, Baquba, Iraq
[2] Univ Baghdad, Inst Laser Postgrad Studies, Baquba 10071, Iraq
[3] Univ Sfax, Dept Comp Tech Engn, Tunis, Tunisia
来源
JOURNAL OF OPTICS-INDIA | 2023年 / 52卷 / 01期
关键词
Micro-cavity; Hollow-core photonic crystal fiber (HCPCF); Hybrid Mach-Zehnder interferometer (HMZI); Sensitivity; DISPERSION TURNING-POINT; REFRACTIVE-INDEX; SENSITIVITY; SENSOR; CAVITY;
D O I
10.1007/s12596-022-00855-7
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An effective procedure for the fabrication of tunable hybrid Mach-Zehnder interferometer (HMZI) based on micro-cavity Fabry-Perot interferometer (FPI) and Mach-Zehnder interferometer (MZI) for load measurement application has been proposed and experimentally investigated. Also, HMZI was developed with 2 types of in-line fiber interferometers, involving dual air micro-cavity FPI as well as compact MZI, which have been shown via fusion splicing a short section which is related to the hollow-core photonic crystal fiber (HCPCF) to the end of single-mode fiber (SMF). MZI and micro-cavity (in-line fiber FPI) have been fabricated through a certain technique of splicing the photonic crystal fiber (PCF) to the traditional SMF and fused tapering, while its dimensions might be excellently managed through controlling series of parameters like HCPCF length and many parameters of splicing like taper length, overlap regarding the 2 fibers as well as the number of arcs. In addition, the experimental results are showing that the micro-cavities with vertical and horizontal length range from extremely low values (16.33 mu m) to extremely high values (38.54 mu m) fabricated with elevated reproducibility, such process might be used for fabricating the micro-air cavities with any dimensions in such range base on user requirements. Also, the experimental results specified that HMZI depending on HCPCF with the use of 2 micro-cavities with regard to load measurement specified that the tunability range has been (1550.993-1552.051) nm with 0.966 nm/N sensitivity. As a result of the benefits of hybrid structure, it is used majorly in aviation industries and engineering health detection.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Torsion Sensor with an Yb-doped Photonic Crystal Fiber Based on a Mach-Zehnder Interferometer
    Sierra-Hernandez, J. M.
    Estudillo-Ayala, J. M.
    Jauregui-Vazquez, D.
    Rojas-Laguna, R.
    Robledo-Fava, R.
    Castillo-Guzman, A.
    Selvas-Aguilar, R.
    Vargas-Rodriguez, E.
    Gallegos-Arellano, E.
    2014 IEEE SENSORS, 2014,
  • [22] Gas refractometry using a hollow-core photonic bandgap fiber in a Mach-Zehnder-type interferometer
    Shavrin, I.
    Novotny, S.
    Shevchenko, A.
    Ludvigsen, H.
    APPLIED PHYSICS LETTERS, 2012, 100 (05)
  • [23] A Mach-Zehnder Interferometer Based on a No-Core Fiber With In-Fiber Waveguides
    Zhang, Hua
    Wang, D. N.
    Wang, Z. K.
    Xu, Ben
    Zhao, C. L.
    Zhang, Shuqin
    Li, Jianqing
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (13) : 1084 - 1087
  • [24] High-sensitivity bend sensor based on Mach-Zehnder interferometer using photonic crystal fiber
    Xu, Xizhen
    Liu, Yingjie
    Sun, Bing
    Liao, Changrui
    Liu, Shen
    Yin, Guolu
    Yang, Kaiming
    Huang, Yijian
    Wang, Yiping
    2015 OPTOELECTRONICS GLOBAL CONFERENCE (OGC), 2015,
  • [25] Mach-Zehnder Interferometer in Embedded-Core Optical Fiber
    Fu, Jianan
    Wang, Meng
    Huang, Peng
    Yang, Jing
    Zhu, Zheng
    Guan, Chunying
    Yuan, Libo
    2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [26] Compact Mach-Zehnder Interferometer Based on Tapered Hollow Optical Fiber
    Zhu, Cong-Cong
    Yu, Yong-Sen
    Zhang, Xuan-Yu
    Chen, Chao
    Liang, Ju-Fa
    Liu, Zi-Jian
    Meng, Ai-Hua
    Jing, Shi-Mei
    Sun, Hong-Bo
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (12) : 1277 - 1280
  • [27] Photonic crystal fiber in-line Mach-Zehnder interferometer for explosive detection
    Tao, Chuanyi
    Wei, Heming
    Feng, Wenlin
    OPTICS EXPRESS, 2016, 24 (03): : 2806 - 2817
  • [28] Measurement of RI and Temperature Using Composite Interferometer With Hollow-Core Fiber and Photonic Crystal Fiber
    Zhao, Yong
    Li, Xue-Gang
    Cai, Lu
    Zhang, Ya-Nan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (11) : 2631 - 2636
  • [29] Miniaturized Tapered Photonic Crystal Fiber Mach-Zehnder Interferometer for Enhanced Refractive Index Sensing
    Ahmed, Farid
    Ahsani, Vahid
    Melo, Luid
    Wild, Peter
    Jun, Martin B. G.
    IEEE SENSORS JOURNAL, 2016, 16 (24) : 8761 - 8766
  • [30] Optimization Analysis of Lateral-Offset Mach-Zehnder Interferometer Based on No-Core Fiber
    Yi, Duo
    Huo, Zhenwei
    Tan, Xiaoling
    Geng, Youfu
    Liu, Fei
    Li, Xuejin
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 14853 - 14859