Fabrication of Hybrid Mach-Zehnder Interferometer based on Hollow-Core Photonic Crystal Fiber for Load Measurement

被引:4
|
作者
Mohammed, Faraqid Q. [1 ]
Mansoor, Tahreer S. [2 ]
Aydi, Yassine [3 ]
机构
[1] Bilad Al Rafidain Univ Coll, Dept Comp Tech Engn, Baquba, Iraq
[2] Univ Baghdad, Inst Laser Postgrad Studies, Baquba 10071, Iraq
[3] Univ Sfax, Dept Comp Tech Engn, Tunis, Tunisia
来源
JOURNAL OF OPTICS-INDIA | 2023年 / 52卷 / 01期
关键词
Micro-cavity; Hollow-core photonic crystal fiber (HCPCF); Hybrid Mach-Zehnder interferometer (HMZI); Sensitivity; DISPERSION TURNING-POINT; REFRACTIVE-INDEX; SENSITIVITY; SENSOR; CAVITY;
D O I
10.1007/s12596-022-00855-7
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An effective procedure for the fabrication of tunable hybrid Mach-Zehnder interferometer (HMZI) based on micro-cavity Fabry-Perot interferometer (FPI) and Mach-Zehnder interferometer (MZI) for load measurement application has been proposed and experimentally investigated. Also, HMZI was developed with 2 types of in-line fiber interferometers, involving dual air micro-cavity FPI as well as compact MZI, which have been shown via fusion splicing a short section which is related to the hollow-core photonic crystal fiber (HCPCF) to the end of single-mode fiber (SMF). MZI and micro-cavity (in-line fiber FPI) have been fabricated through a certain technique of splicing the photonic crystal fiber (PCF) to the traditional SMF and fused tapering, while its dimensions might be excellently managed through controlling series of parameters like HCPCF length and many parameters of splicing like taper length, overlap regarding the 2 fibers as well as the number of arcs. In addition, the experimental results are showing that the micro-cavities with vertical and horizontal length range from extremely low values (16.33 mu m) to extremely high values (38.54 mu m) fabricated with elevated reproducibility, such process might be used for fabricating the micro-air cavities with any dimensions in such range base on user requirements. Also, the experimental results specified that HMZI depending on HCPCF with the use of 2 micro-cavities with regard to load measurement specified that the tunability range has been (1550.993-1552.051) nm with 0.966 nm/N sensitivity. As a result of the benefits of hybrid structure, it is used majorly in aviation industries and engineering health detection.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Fabrication of Hybrid Mach-Zehnder Interferometer based on Hollow-Core Photonic Crystal Fiber for Load Measurement
    Faraqid Q. Mohammed
    Tahreer S. Mansoor
    Yassine Aydi
    Journal of Optics, 2023, 52 : 1 - 9
  • [2] Hollow-Core Photonic Crystal Fiber Mach-Zehnder Interferometer for Gas Sensing
    Nazeri, Kaveh
    Ahmed, Farid
    Ahsani, Vahid
    Joe, Hang-Eun
    Bradley, Colin
    Toyserkani, Ehsan
    Jun, Martin B. G.
    SENSORS, 2020, 20 (10)
  • [3] Monitoring of Carbon Dioxide Using Hollow-Core Photonic Crystal Fiber Mach-Zehnder Interferometer
    Ahmed, Farid
    Ahsani, Vahid
    Nazeri, Kaveh
    Marzband, Ehsan
    Bradley, Colin
    Toyserkani, Ehsan
    Jun, Martin B. G.
    SENSORS, 2019, 19 (15)
  • [4] In-fiber Mach-Zehnder interferometer for gas refractive index measurements based on a hollow-core photonic crystal fiber
    Andrews, Nicholas L. P.
    Ross, Rachel
    Munzke, Dorit
    van Hoorn, Camiel
    Brzezinski, Andrew
    Barnes, Jack A.
    Reich, Oliver
    Loock, Hans-Peter
    OPTICS EXPRESS, 2016, 24 (13): : 14086 - 14099
  • [5] Optical fiber temperature sensor with Vernier effect formed by Mach-Zehnder interferometer cascaded Sagnac interferometer based on Hollow-core photonic crystal fiber
    Su, Hang
    Gao, Laixu
    Zhang, Zhaorong
    Kong, Fanxin
    Dong, Zhen
    Zhao, Chunlong
    Xiao, Dehang
    Liu, Chunyu
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2022, 52
  • [6] A Novel Mach-Zehnder Interferometer Based on Hybrid Liquid Crystal-Photonic Crystal Fiber
    Luo, Xian-Ping
    Wang, Fei-Ru
    Chen, Chun-Lei
    Zhang, Ling-Li
    Wang, Lei
    Sun, Wei-Min
    Liu, Yong-Jun
    CHINESE PHYSICS LETTERS, 2017, 34 (12)
  • [7] Compact Mach-Zehnder interferometer based on processed hollow-core fiber for gas pressure sensing
    Wu, Yue
    Wang, Shuai
    Meng, Fanyong
    Song, Yanming
    Zhu, Lianqing
    JOURNAL OF NANOPHOTONICS, 2019, 13 (03)
  • [8] High sensitivity Mach-Zehnder interferometer based on peanut-shaped hollow-core fiber
    Zhu, Xiaojun
    Pan, Yongquan
    Sun, Ang
    Liu, Wen
    Song, Mengqiang
    Liu, Xing
    Cao, Juan
    Zhang, Guoan
    Yang, Yongjie
    Liang, Zhipeng
    Shi, Yuechun
    Wu, Wuming
    OPTICS COMMUNICATIONS, 2023, 542
  • [9] Compact Mach-Zehnder interferometer-based no-core fiber hollow-core fiber no-core fiber structure
    Wu, Yue
    Yang, Yuguang
    Jin, Wenxing
    Shen, Ya
    Jian, Shuisheng
    OPTICAL ENGINEERING, 2017, 56 (03)
  • [10] Temperature insensitive fiber Fabry-Perot/Mach-Zehnder hybrid interferometer based on photonic crystal fiber for transverse load and refractive index measurement
    Wang, Jin
    Liu, Bo
    Wu, Yongfeng
    Mao, Yaya
    Zhao, Lilong
    Sun, Tingting
    Nan, Tong
    Han, Yang
    OPTICAL FIBER TECHNOLOGY, 2020, 56