An Assessment of the Structural Performance of Rebar-Corroded Reinforced Concrete Beam Members

被引:1
作者
Kim, Hyungrae [1 ]
Yang, Sungchul [2 ]
Noguchi, Takafumi [3 ]
Yoon, Sangchun [4 ]
机构
[1] Hyundai Engn & Construct, Seoul 03058, South Korea
[2] Hongik Univ, Sch Architectural Engn, Sejong 30016, South Korea
[3] Univ Tokyo, Grad Sch Engn, Tokyo 1138654, Japan
[4] Gachon Univ, Dept Architectural Engn, Seongnam 13120, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 19期
关键词
RC beam specimen; local rebar corrosion; degree of corrosion; corrosion rate; corrosion area; monotonic loading; cyclic loading; structural performance; RC BEAMS; FLEXURAL STRENGTH; CORROSION PROCESS; BOND STRENGTH; BEHAVIOR; SIMULATION; PREDICTION; COVER; LOAD;
D O I
10.3390/app131910927
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper aims to determine the effects of local corrosion at three different corrosion areas, the (1) entire area, (2) the constant moment area, and (3) the constant shear area, on the flexural performance of RC beams. To analyze this, an experimental study was carried out to prepare two series of RC beams (200 x 300 x 2800 mm) created with three different degrees of corrosion, inducing local rebar corrosion. Furthermore, two series of experimental tests were conducted under different loading types: monotonic and cyclic loading. It was observed that the strength capacity reduction grew in the RC specimens with induced corrosion in the order of the (1) entire area > (2) the constant moment area > (3) the constant shear area, as the average corrosion rate increased. Our test results further showed that the yield and ultimate strength were kept nearly equivalent to the uncorroded RC specimen, with average corrosion rates of 10% and 15%, respectively. Over these corrosion rates, the yield strength and ultimate strength dropped significantly. Compared to the test results under a monotonic loading condition, the structural capacity under a cyclic loading condition decreased, with a more pronounced tendency for each corrosion case as the corrosion rate increased. Longitudinal cracks developed throughout and adjacent to the corrosion areas as the corrosion rate increased. Thus, we can infer that strength reductions may be strongly influenced by these longitudinal cracks.
引用
收藏
页数:17
相关论文
共 72 条
  • [51] Study on the bond behavior of corroded steel bars embedded in concrete under the coupled effect of reciprocating loads and chloride ion erosion
    Shang, Huaishuai
    Zhou, Junhao
    Yang, Guotao
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2021, 305
  • [52] 3D X-ray Micro-CT Analysis of Rebar Corrosion in Reinforced Concrete Subjected to a Chloride-Induced Environment
    Skarzynski, Lukasz
    Kibort, Katarzyna
    Malachowska, Aleksandra
    [J]. MOLECULES, 2022, 27 (01):
  • [53] Probabilistic prediction model for RC bond failure mode
    Soraghi, Ahmad
    Huang, Qindan
    [J]. ENGINEERING STRUCTURES, 2021, 233
  • [54] Spatial variability of pitting corrosion and its influence on structural fragility and reliability of RC beams in flexure
    Stewart, MG
    [J]. STRUCTURAL SAFETY, 2004, 26 (04) : 453 - 470
  • [55] Suwito A, 2004, LIFE-CYCLE PERFORMANCE OF DETERIORATING STRUCTURES: ASSESSMENT, DESIGN, AND MANAGEMENT, P207
  • [56] Investigating correlations between crack width, corrosion level and anchorage capacity
    Tahershamsi, Mohammad
    Fernandez, Ignasi
    Lundgren, Karin
    Zandi, Kamyab
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2017, 13 (10) : 1294 - 1307
  • [57] Numerical study of corrosion crack opening
    Thoft-Christensen, Palle
    Frandsen, Henrik L.
    Svensson, Staffan
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2008, 4 (05) : 381 - 391
  • [58] Influence of corrosion on the structural stiffness of reinforced concrete beams
    Torres-Acosta, AA
    Fabela-Gallegos, MJ
    Muñoz-Noval, A
    Vázquez-Vega, D
    Hernandez-Jimenez, JR
    Martínez-Madrid, M
    [J]. CORROSION, 2004, 60 (09) : 862 - 872
  • [59] Residual flexure capacity of corroded reinforced concrete beams
    Torres-Acosta, Andres A.
    Navarro-Gutierrez, Sergio
    Teran-Guillen, Jorge
    [J]. ENGINEERING STRUCTURES, 2007, 29 (06) : 1145 - 1152
  • [60] Degradation Monitoring in Reinforced Concrete with 3D Localization of Rebar Corrosion and Related Concrete Cracking
    Van Steen, Charlotte
    Verstrynge, Els
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (15):