Gastrointestinal bleeding and pro-angiogenic shift in the angiopoietin axis with continuous flow left ventricular assist device implantation

被引:0
作者
Edwards, Adam L. [1 ]
Wilcox, C. Mel [1 ]
Beasley, Mark [2 ]
Pamboukian, Salpy V. [1 ,3 ,4 ]
Mannon, Peter [1 ,4 ]
Peter, Shajan [5 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Dept Med, Div Gastroenterol & Hepatol, Birmingham, AL USA
[2] Univ Alabama Birmingham, Sch Publ Hlth, Birmingham, AL USA
[3] Univ Alabama Birmingham, Sch Med, Dept Med, Div Cardiovasc Dis, Birmingham, AL USA
[4] Univ Nebraska Med Ctr, Coll Med, Dept Internal Med, Div Gastroenterol & Hepatol, Omaha, NE USA
[5] Univ Alabama Birmingham, Sch Med, Dept Med, Div Gastroenterol & Hepatol, BDB 389,1720 2nd Ave S, Birmingham, AL 35294 USA
关键词
Gastrointestinal bleeding; Left ventricular assist device; Angiopoietin; VON-WILLEBRAND SYNDROME; ARTERIOVENOUS-MALFORMATIONS; SHEAR-STRESS; RISK; PULSATILITY; HYPOXIA;
D O I
10.1016/j.amjms.2023.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Gastrointestinal bleeding (GIB) affects up to 40% of continuous-flow left ventricular assist device (CF-LVAD) recipients. A higher risk of GIB is seen in CF-LVAD recipients with lower device pulsatility without a known mechanism. One hypothesis is that the novel hemodynamics in CF-LVAD recipients affect angiogenesis signaling. We aimed to (1) measure serum levels of angiopoietin (Ang)-1, Ang-2, and VEGF-A in CF-LVAD recipients with and without GIB and in healthy controls and (2) evaluate correlations of those levels with hemodynamics. Methods: We recruited 12 patients with CF-LVADs (six who developed GIB after device implantation) along with 12 age-matched controls without heart failure or GIB and measured Ang-1, Ang-2, and VEGF-A levels in serum samples from each patient. Results: CF-LVAD recipients had significantly higher Ang-2 and lower Ang-1 levels compared to controls with no difference in VEGF-A levels. CF-LVAD recipients with GIB had lower Ang-1 levels than those without GIB. There were trends for pulse pressure to be positively correlated with Ang-1 levels and negatively correlated with Ang-2 levels in CF-LVAD recipients with no correlation observed in healthy controls. Conclusion: CF-LVAD recipients demonstrated a shift toward a pro-angiogenic phenotype in the angiopoietin axis that is significantly associated with GIB and may be linked to low pulse pressure.
引用
收藏
页码:278 / 285
页数:8
相关论文
共 50 条
  • [21] Gastrointestinal Bleeding in Left Ventricular Assist Device: Octreotide and Other Treatment Modalities
    Molina, Tara L.
    Krisl, Jill C.
    Donahue, Kevin R.
    Varnado, Sara
    ASAIO JOURNAL, 2018, 64 (04) : 433 - 439
  • [22] Clinical Approach to Manage Gastrointestinal Bleeding with a Left Ventricular Assist Device (LVAD)
    Ahsan, Irfan
    Faraz, Aniqa
    Mehmood, Asif
    Ullah, Waqas
    Ghani, Ali
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (12)
  • [23] Gastrointestinal bleeding after left ventricular assist device implantation: It is all about the platelets
    Crestanello, Juan A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (01) : 228 - 229
  • [24] Defining Vasoplegia Following Durable, Continuous Flow Left Ventricular Assist Device Implantation
    Swan, Joshua T.
    Iso, Tomona
    Rizk, Elsie
    Trachtenberg, Barry H.
    Krisl, Jill
    Varnado, Sara
    Suki, Wadi N.
    Frost, Adaani E.
    Suarez, Erik
    Uddin, Faisal S.
    Kassi, Mahwash
    Giesecke, Noel Martin
    Bhimaraj, Arvind
    Masud, Faisal N.
    ASAIO JOURNAL, 2022, 68 (01) : 46 - 55
  • [25] Preoperative predictors and outcomes of right ventricular assist device implantation after continuous-flow left ventricular assist device implantation
    Patil, Nikhil Prakash
    Mohite, Prashant N.
    Sabashnikov, Anton
    Dhar, Dhruva
    Weymann, Alexander
    Zeriouh, Mohamed
    Hards, Rachel
    Hedger, Michael
    De Robertis, Fabio
    Bahrami, Toufan
    Amrani, Mohamed
    Rahman-Haley, Shelley
    Banner, Nicholas R.
    Popov, Aron Frederik
    Simon, Andre Ruediger
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (06) : 1651 - 1658
  • [26] Gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A comprehensive review
    Del Rio-Pertuz, Gaspar
    Nair, Nandini
    ARTIFICIAL ORGANS, 2023, 47 (01) : 12 - 23
  • [27] Association between digoxin use and gastrointestinal bleeding in contemporary continuous flow left ventricular assist device support
    El Rafei, Abdelghani
    Trachtenberg, Barry H.
    Schultz, Jessica
    John, Ranjit
    Estep, Jerry D.
    Araujo-Gutierrez, Raquel
    Suarez, T. Eric E.
    Goodwin, Kevin
    Cogswell, Rebecca
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (07) : 671 - 676
  • [28] Limited usefulness of endoscopic evaluation in patients with continuous-flow left ventricular assist devices and gastrointestinal bleeding
    Axelrad, Jordan E.
    Pinsino, Alberto
    Trinh, Pauline N.
    Thanataveerat, Anusorn
    Brooks, Christian
    Demmer, Ryan T.
    Effner, Lisa
    Parkis, Grant
    Cagliostro, Barbara
    Han, Jiho
    Garan, A. Reshad
    Topkara, Veli
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Ramirez, Ivonne
    Garcia-Carrasquillo, Reuben
    Colombo, Paolo C.
    Gonda, Tamas
    Yuzefpolskaya, Melana
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (06) : 723 - 732
  • [29] Characteristics of Gastrointestinal Bleeding After Placement of Continuous-Flow Left Ventricular Assist Device: A Case Series
    Joseph Marsano
    Jay Desai
    Shannon Chang
    Michelle Chau
    Mark Pochapin
    Grigoriy E. Gurvits
    Digestive Diseases and Sciences, 2015, 60 : 1859 - 1867
  • [30] Characteristics and outcomes of gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A systematic review
    Carlson, Laura A.
    Maynes, Elizabeth J.
    Choi, Jae Hwan
    Hallett, Andrew M.
    Horan, Dylan P.
    Weber, Matthew P.
    Deb, Avijit K.
    Patel, Sinal
    Samuels, Louis E.
    Morris, Rohinton J.
    Entwistle, John W.
    Massey, H. Todd
    Tchantchaleishvili, Vakhtang
    ARTIFICIAL ORGANS, 2020, 44 (11) : 1150 - 1161